• Title/Summary/Keyword: Sewerage pipe

Search Result 29, Processing Time 0.02 seconds

Removal Method for a Deposit at Sewerage with Polymer Additives (폴리머를 이용한 하수관로에서의 퇴적물 제거 기법)

  • Jeon, Chan-Yeal;Oh, Yool-Kwon;Hwang, Se-Joon
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.153-159
    • /
    • 2002
  • This experimental study is aimed to increasing the velocity in the sewerage and also development of easy removal method for a corrosion and sand in the flow pipe. And the result by the increasing the out flow per unit time, diameter of sewerage pipe is becoming small size, cut down the construction fee and the same time reducing the tubulent flow pattern in the flow pipe. As a result of detected experimental velocity signal from the probe in the test wall surface, reducing the pump power and increasing the out flow unit time. Apparent water velocity decreases as the value of void ratio increases depends on the varies center of pipe.

Comparison of Biofilm Formed on Stainless Steel and Copper Pipe Through the Each Process of Water Treatment Plant (정수처리 공정 단계별 스테인리스관과 동관에 형성된 생물막 비교)

  • Kim, Geun-Su;Min, Byung-Dae;Park, Su-Jeong;Oh, Jung-Hwan;Cho, Ik-Hwan;Jang, Seok-Jea;Kim, Ji-Hae;Park, Sang-Min;Park, Ju-Hyun;Chung, Hyen-Mi;Ahn, Tae-Young;Jheong, Weonhwa
    • Korean Journal of Microbiology
    • /
    • v.49 no.4
    • /
    • pp.313-320
    • /
    • 2013
  • Biofilm formed on stainless and copper in water treatment plant was investigated for sixteen weeks. Biofilm reactor was specially designed for this study. It was similar to that of a real distribution pipe. Raw water, coagulated, settled, filtered and treated water were used in this study. The average number of heterotrophic bacteria counts was $1.6{\times}10^4CFU/ml$, $5.8{\times}10^3CFU/ml$, $1.8{\times}10^3CFU/ml$, $1.3{\times}10^2CFU/ml$, 1 CFU/ml, respectively. Density of biofilm bacteria formed on stainless and copper pipes in raw, coagulated and settled water increased above $2.9{\times}10^3CFU/cm^2$ within second weeks while more biofilm bacteria counts were found on the stainless pipe than on the copper pipe. In case of filtered water (free residue chlorine 0.44 mg/L), there was no significant difference in the number of biofilm bacteria on both pipes and biofilm bacteria below $18CFU/cm^2$ were detected on both pipe materials after fifth weeks. Biofilm bacteria were not detected on both pipe materials in treated water (free residue chlorine 0.88 mg/L). According to the results of DGGE analysis, Sphingomonadacae was a dominant species of biofilm bacteria formed on the stainless pipe while the copper pipe had Bradyrhizobiaceae and Sphingomonadaceae as dominant bands. In case of filtered water, a few bands (similar to Propionibacterium sp., Sphingomonas sp., Escherichia sp., and etc.) that have 16S rRNA sequences were detected in biofilm bacteria formed on both pipes after fifth weeks. Stainless pipe had higher species richness and diversity than the copper pipe.

Minimum Velocity of Sewerage Pipes (하수관거의 최저유속)

  • Yu, Dong-Hun;Lee, Jeong-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.4
    • /
    • pp.469-478
    • /
    • 1999
  • Explicit equations of minimum velocity, energy slope and pipe diameter are developed to ensure the cleaning of sewerage pipes. The equations of power form are employed for the estimation of critical shear stress of sediment particles and the friction factor of commercial pipes. They are all based on the existing laboratory data. Several cases are tested to check the values suggested in the manual, using the equations developed in the present study.

  • PDF

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

Design and Fundamental Experiment on Trenchless Replacement of Old Sewerage (노후하수관 교체시 비굴착방식 신공법기술개발)

  • Noh, Jong-Ho;Lee, Young-Ki;Roh, Hong-Koo;Han, Min-Ho;Lee, Sung-Chul;Lim, Il
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1327-1331
    • /
    • 2008
  • The study aims to enhance the trenchless replacement of old sewerage. The trenchless replacement was designed as real size and tested in the field of construction. This trenchless replacement was new technology in construction. The result was good performance in the construction. In the future, the trenchless replacement should be use as the exchange equipment of old sewerage.

  • PDF

A Study on Building Sewerage Data using Dynamic Segmentation Method (Dynamic Segmentation을 이용한 오수 관거 데이터구축에 관한 연구)

  • Park, Jeong-Wo;Yun, Jeong-Mi;Lee, Sung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.2
    • /
    • pp.11-19
    • /
    • 2006
  • Sewerage is the system that improves the quality of human life and prevents many disasters such as floods. However the investigators in Korea only have been concerned about the sewer system, so the sewage treatment plant stays in the basic level like mapping. For example, only one attribute can be recognized in the linear object. Because of this limitation, it makes difficult to manage the linear attribute regarding to the sewage pipe plan. And it is impossible to control a partial (point type, line type) attribute changes of the linear object. We will therefore present the applicable method for the attribute changes of the linear object like the sewage pipe plans. For this reason, this paper is designed on the basis of Dynamic Segmentation(DS). DS has the advantage of giving the attribute value to the exact place in the linear object. As a result of using DS, the variety environment changes around the sewage pipes are applied to the building sewerage data. This also makes it possible to get a precise estimation for the maximum dirty water amount.

  • PDF

A Case Study of Flexible Sewer Pipes Behaviors - Compaction Ratio·Inner Deflection Ratiov·Ring Stiffness - (현장중심형 하수도용 연성관의 거동특성에 대한 고찰 - 다짐도·변형률·강성 간의 관계정립 -)

  • Kim, Young-Jin
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.2
    • /
    • pp.31-38
    • /
    • 2013
  • As the Sewer Pipe is transformed by the expansion of life cycle as a result of the technology development, flexible pipe is developed by the transformed environmental conditions. To change pipe design, three phases(compaction ration - inner deflection ratio - ring stiffness) should be considered in design conditions. The input data of pipe design were provided by compaction-inner deflection ratio-ring stiffness. M oreover, The guidelines of sewerage pipes should be considered by flexible pipes design criteria.

Effect of infiltration/inflow by rainfall for sewerage facilities in the area with partially separate sewer system (불완전 분류식 하수처리구역의 강우에 의한 하수도시설의 침입수/유입수 영향 분석)

  • Shin, Jungsub;Han, Sangwon;Yook, Junsu;Lee, Chungu;Kang, Seonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.177-190
    • /
    • 2019
  • The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.

Analysis of the wastewater characteristics variation in sewerage by rehabilitation (관거 정비에 따른 하수발생특성 분석)

  • Jung, SiMon;Park, InHyeok;Park, JungHa;Ha, SungRyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.287-293
    • /
    • 2009
  • The study involved the measurement of flowrate and BOD in the Yeoju area and analyzed annual sewerage data by the I/I analysis technique which is common in Korea. The results of this study are as follows. The I/I for the Y-1 site before maintenance and after the completion of the whole process was reduced from 62% to 16.1% respectively with respect to maximum sewage flow per day. The average quality of water increased. The study measured the Y-2 site from a point of time corresponding to an 80% process rate and its I/I rate went up a little from 8.5% to 11.5%. At the Y-3 site, the I/I rate went up a little from 11% to 13.8%, while little change was noted in the average water quality. At the Y-4 site, the I/I rate was reduced from 43% to 16.9% and its average water quality went up. At the Y-5 site, the I/I quantity went up a little however its average water quality also went up largely. Therefore, it was concluded that the Y-5 site showed great improvement due to the sewer pipe maintenance.

The Management of Water Supply and Sewerage Facilities using GIS Technique for Urban Local Area (도시내 소규모 단지의 상.하수도 시설물관리를 위한 GIS 기술의 활용)

  • 김충평;김감리
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.1
    • /
    • pp.51-59
    • /
    • 1999
  • Today there are many problems of facility management, water supply and sewerage, because expansion of urban and growing of population, limitation of old facility management. The nearest, it is needed to use GIS technique to reduce the pollution of underground water from sewage leaking and to make quick search of an accident area for water service pipe damage. Therefore, this paper shows that GIS is efficient and scientific technique for management of Urban facilities, water supply and sewerage. Finally, I think that this study help managers of facilities.

  • PDF