• Title/Summary/Keyword: Sewage water source

Search Result 176, Processing Time 0.026 seconds

A Study on Production of Chlorophenols by Chlorinaion of Drinking Water (상수 염소 소독에 의한 클로로페놀 생성에 관한 연구)

  • Chung, Yong;Kwon, Sook-Pyo;Park, Ha-Young
    • YAKHAK HOEJI
    • /
    • v.24 no.2
    • /
    • pp.87-95
    • /
    • 1980
  • Chlorination to polluted water can produce chlorocompounds which may impair human health. It has been discussed that chlorophenols would be one of undesirable substances in drinking water. This study was undertaken to investigate the production mechanism of chlorophenols by chlorination in the disinfection of water and to determine pollution levels of phenols as precursor of chlorophenols and chloropbenols in some sewage, stream water and tap water in the vicinity of Seoul from January to September, 1979. By chlorination with hyperchlorite to phenols in distilled water, o-chlorophenol was predominantly produced at the concentration of less than 10ppm of free chlorine. o-Chlorophenol, 2,6-dichlorophenol and 2,4-dichlorophenol were also produced by chlorination with the concenration from 20 to 100ppm of free chlorine. From the concentration of 100ppm of free chlorine to 200ppm, o-Chlorophenol was vanished and 2,6-dichlorophenol and 2,4-dichlorophenol were determined. Phenols originated from night soil, municipal sewage and stream were determined at 49.15 ppm. 0.095 ppm and 0.003 ppm in average respectively. About 87 and 88 percent of phenols in sewage and night soil were biodegradated by aeration for 10 days and 74 and 51 percent of phenols in sewage and night soil by spontaneous settling for 10 days. From the tap water in Seoul during summer, 1979, chlorophenols were identified; they were average 0.042 ppb of o-chlorophenol, 0.033 ppb of 2, 6-dichlorophenol and 0.003 ppb of 2, 4-dichlorophenol respectively. With the above result and discussion, it is considered that chlorophenols should be controlled from the source as well as chlorination in water purification.

  • PDF

Wastewater-based epidemiology for the management of community lifestyle and health: An unexplored value of water infrastructure (하수기반역학을 이용한 커뮤니티 생활상 및 건강 관리: 물 인프라의 새로운 가치)

  • Jho, Eun-Hea;Kim, Hyoung-Il;Choi, Yongju;Youn, Youngho;Lee, Doyeon;Kim, Geunyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.63-77
    • /
    • 2019
  • Traditional wastewater research mainly focuses on 1) estimating the amount of waste entering sewage treatment facilities, 2) evaluating the treatment efficiency of sewage facilities, 3) investigating the role of sewage treatment effluent as a point source, and 4) designing and managing sewage treatment facilities. However, since wastewater contains a variety of chemical and biological substances due to the discharge of human excreta and material used for daily living into it, the collective constituents of wastewater are likely a reflection of a community's status. Wastewater-based epidemiology (WBE), an emerging and promising field of study that involves the analysis of substances in wastewater, can be applied to monitor the state of a defined community. WBE provides opportunities for exploiting indicators in wastewater to fulfill various objectives. The data analyzed under WBE are those pertaining to selected natural and anthropogenic substances in wastewater that are a result of the discharge of metabolic excreta, illicit or legal drugs, and infectious pathogens into the wastewater. This paper reviews recent progress in WBE and addresses current challenges in the field. It primarily discusses several representative applications including the investigation of drug consumption across different communities and the management of community disease and health. Finally, it summarizes established indicators for WBE.

Distribution of Organic Matter and Nitrogenous Oxygen Demand in Effluent of Sewage and Wastewater Treatment Plants (하·폐수처리시설 방류수내 유기물질 및 NOD 분포 특성)

  • Kim, Ho-Sub;Kim, Seok-Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.20-31
    • /
    • 2021
  • In this study, an analysis of the characteristics of organic matter and nitrogenous oxygen demand (NOD) of 17 sewage effluent and wastewater treatments was conducted. High CODMn and carbonaceous biological oxygen demand (CBOD) concentrations were observed in the livestock treatment plants (LTP), wastewater treatment plants(WTP), and night soil treatment plants (NTP), but the highest NOD concentration and contribution rates of NOD to BOD5 were found in sewage treatment plants (STP). There was no significant difference in the CBOD/CODMn ratio for each of the six pollution source groups, but the LTPs, WTPs, and NTPs all showed relatively high CODMn concentrations in their effluent samples, indicating that they are facilities which discharge large amounts of refractory organic matter. The seasonal change of NOD in all facilities' effluent was found to be larger than the seasonal change of CBOD, and data results also revealed an elevation of NOD and NH3-N concentration from December to February, when the water temperature was low. There was no significant difference in NH3-N concentration in relation to pollution source group (p=0.08, one-way ANOVA), but the STP, which had a high NOD contribution rate to BOD5 of 48%, showed a high correlation between BOD5 and NOD (r2=0.95, p<0.0001). These results suggest that the effect of NOD on BOD5 is an important factor to be considered when analyzing STP effluent.

Sterols as Indicators of Fecal Pollution in Sediments from Shellfish Farming Areas (Yeoja Bay and Gangjin Bay) of Korea (분변계 스테롤을 이용한 남해안 패류양식어장(여자만과 강진만)의 퇴적물내 분변오염도 평가)

  • Choi, Minkyu;Lee, In-Seok;Hwang, Dong-Woon;Kim, Hyung Chul;Kim, Ye-Jung;Kim, Sook-Yang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.4
    • /
    • pp.437-444
    • /
    • 2013
  • Eight fecal sterols were analyzed in surface sediments collected from shellfish farming areas in Yeoja Bay and Gangjin Bay, Korea, to evaluate sewage-derived fecal pollution. The concentrations of coprostanol, a good marker of sewage-derived organic contamination, in sediments were in the range of 10-530 ng/g-dry in Yeoja Bay, and 10-190 ng/g-dry in Gangjin Bay. Coprostanol levels were markedly higher in the inner bay than in the outer bay. These levels were lower than those reported in urbanized bays in Korea, however, they were comparable to levels in other shellfish farming areas including Gamak Bay. A multivariate analysis of the ratios of other sterols suggested that the sterols originated from sewage and plankton/benthos. Sewage was the dominant source at stations located close to the river mouth and wastewater treatment plant (WWTP) outfalls, and plankton/benthos was the primary source in the outer bay. These results suggest that management of point sources, e.g., WWTP as well as non-point sources, e.g., riverine inputs is important for improving the water quality in Yeoja Bay and Gangjin Bay.

Optimal Management Scheme for Phosphorus Discharged from Public Sewage Treatment Plant Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 공공 하수종말처리시설의 총인 배출 최적관리)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Jeong, Myungsuk;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.200-209
    • /
    • 2011
  • The purpose of the study is to optimally manage sewage treatment plant with analysis of phosphorus contribution and improvement of water quality contributing rate in the effect of inflowing point of effluent and Pal-Dang lake after reducing T-P discharge from large scale public sewage treatment plant at upstream of Pal-Dang lake. Also, this study, for enforcement of T-P in effluent, plans optimal management of effluent T-P through examining propriety of environmental, technological, and economical aspect such as water quality standard of domestic and foreign T-P and related policy. In regarding optimal management of T-P discharged from public sewage treatment plant located in upstream of Pal-Dang lake, the study drew following conclusions. With the optimal management of public sewage treatment plant, it showed that a pollution level became higher in the order of Sumgang E in South-Han river, C in Dalcheon, B1 B2, A in North-Han river, and J in Kyungancheon, and it is required reduction of T-P first. The highest value in analysis of benefit-costs from sewage treatment plant in the selected research area was Kyungan B, and the others are with the order of Jojong A, Bokha A, Kyungan A, and Yanghwa A. With result of this study, all 14 areas are required more enforced phosphorus treatment. The study resulted that the most top priority areas were Hangang F, Sumgang B, and Gyungan A, top priority areas were Bokha A, Dalcheon B, and Cheongmi A, priority areas were Hangang E, Heukcheon A, Gyungan B, and Jojong A, and potential areas were Sumgang A, Yanghwa A, Dalcheon A, and Hangang D. It seems to be appropriate to apply 0.2 mg/L of T-P treatment for water supply source reservation, 0.5 mg/L for the other areas by locally, and 0.2~0.5 mg/L for biological nitrogen phosphorus treatment method and 0.5~1 mg/L for Conventional Activated Sludge by technologically. Also, it may be appropriate to apply 0.2 mg/L for the most top priority area(I), 0.3 mg/L for the top priority area(II), 0.4 mg/L for priority area(III), and 0.5 mg/L for potential area(IV) by the separation of priority area.

Water Quality Modeling and Environmantal Capacity in the Seom River Basin (섬강유역 환경용량 및 수질 Modeling)

  • 허인량;오근찬;최지용
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.80-86
    • /
    • 1998
  • Seom River was major branch of Namhan river, consist of primary basin that Wonjoo-city, Hoingsung-gun and primary contamination source was sewage from human lives. This study was evaluated production contamination loading of each branch basin and water quality grade and water quality simulation by QUAL2E to provide efficient contaminations source control. Rusult of survey, production loading of BOD, T-N, T-P were 26,591 kg/day, 4,560 kg/day, 731 kg/day resectively. Water quality analysis in 17 points of main stream were appeared that 1st grade(BOD 1 mg/l under) was 6 point, 2nd grade was 9 point and 3rd grade was 2 point. And result of water quality analysis for branch steram, first grade was evaluated 68.7%. Based of field data, calibration and verification result were in good agreement with mesured value within coefficient of variance were from 2.59% to 18.73%, from 6.39%, to 28.46%, respectively.

  • PDF

Pesticide Analysis in Drinking Water by SPE Method (SPE법에 의한 음료수중 농약성분)

  • 김형석
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.59-66
    • /
    • 1995
  • According to the population increase and industrialization, the drinking water source, Han River and other sources, are contaminated by industrial wastewater, domestic sewage, and agricultural discharges. Among the contaminants, and toxic substances, pesticides is most interesting items (or human health Our drinking water has some problems of THMs, Fe, odor, etc., $o many people use groundwater or bottled water. But sometimes there are many reports about groundwater contamination owing to the agricultural chemicals, waste disposal, industrial wastewater. In America, there are about 45,000 groundwave supply company and in korea about 20% of total population are using groundwave as drinking water source. In America, studies about SEE is increasing Instead of liquid- liquid extraction method, because of many advantages of SEE methods. Author tried to investigate SPE methods in the spiked water samples to compare with liquid- liquid extraction method and got the following results. The amount of organic solvents which are used In SPE method is less than 1/10 compared with liquid- liquid method, the analytical duration time is shortened, and the ethyl acetate was good fluent among several organic solvents.

  • PDF

Regional Characteristics of Nonpoint Source Pollutant Loads in the Upstream Watersheds of Nakdong River (낙동강 상류유역의 지역별 비점오염부하 특성)

  • Choe, Gyeong-Suk;Son, Seong-Ho
    • KCID journal
    • /
    • v.13 no.2
    • /
    • pp.283-292
    • /
    • 2006
  • The characteristics of nonpoint source pollutant loads in upstream of Nakdong River were studied through analysis of pollutant loads of 10 sub-watersheds divided based on administrative district. The discharge and pollutant concentration of each sub-watershed were collected from Nakdong-River Water Research Institute and Daegu Regional Environmental office, respectively. Pollution items analysed in this study were BOD, T-N and T-P. The delivery loads of the nonpoint source pollutions of each sub-watershed were calculated after analysing the concentration of the pollution of each site. Several points were found from the results. Firstly, in general, city areas including Sangju, Andong showed higher degree of nonpoint pollution than country areas including Cheongsong, Yeongyang. The sub-watersheds located upstream side, such as Yeongju, Bonghwa, Necessarily show better water quality than the sub-watersheds located downstream side, such as Mungyeong, Uiseong. This result indicates that a given pollution condition within the watershed can be more sensitive than location factor to the level of water quality. Secondly, the delivery load and area of watershed were not necessarily correlated in the sense of water quality, while the discharge was shown to be highly correlated to the delively load of pollution. Lastly, sewage and waste caused from population and livestock, as well as landuse factor, were found to significantly contribute to the water pollution. Alternative solutions for controlling pollution source, therefore, should be provided to meet target levels of water quality in these regions.

  • PDF

Improvement on Sewerage Effluent Standard of Public Sewerage Treatment Plants (공공하수처리시설 수질기준 선진화 방안)

  • Yu, Soon-Ju;Park, Sang-Min;Kwon, Oh-Sang;Park, Su-Jeong;Yeom, Ick-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.276-287
    • /
    • 2013
  • Domestic sewage contains increasingly more pharmaceuticals and personal care products (PPCPs), due to rising use of medicines, health supplement food and daily necessities. And various types of industrial wastewater from pollution sources in treatment areas could flow into the public sewerage treatment plants (PSTPs) in metropolitan areas. The conventional PSTPs are designed to treat suspended solids, biodegradable organics, nitrogen and phosphorous from residential and industrial areas and public facilities. However, toxic, conventional, and non-coventional pollutants from non-domestic sources that discharge into sewer system as well as domestic source with various chemicals could not be treated in the conventional PSTPs and discharged untreated to public basin. In this paper we aim to consider the establishment system of effluent standard of PSTPs in comparison with water quality standard of water environment and wastewater discharge regulation. And also we suggest the necessity of regulations on the pretreatment of industrial wastewater as part of efforts to improve water quality in sewerage systems and to protect public basin.