• Title/Summary/Keyword: Sewage treatment system

Search Result 372, Processing Time 0.038 seconds

Redescription of Previously Unknown Euplotine Ciliates, Euplotes charon and Diophrys oligothrix (Ciliophora: Spirotrichea: Euplotida), from Korea

  • Kwon, Choon-Bong;Shin, Mann-Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • v.22 no.1
    • /
    • pp.29-35
    • /
    • 2006
  • Two ciliates of suborder Euplotina collected from the two habitats (estuarine littoral and sewage treatment plant) in Ulsan, Korea were Euplotes charon ($M\ddot{u}ller$, 1773) and Diophrys oligothrix Borror, 1965. These two species are reported for the first time from Korea. The description was based on the observation of living and silver impregnated specimens. Diagnostic characteristics of these species are as follows. E. charon: size in vivo about $90-130\times65-80{\mu}m$, adoral zone of membranelles over 79.5% of cell length with 54-80 adoral membranelles; right margin of the peristome shaped sinusoidal form and passed through adoral zone of membranelles; buccal cavity wide anteriorly; 10 frontoventral, 5 transverse, 4 caudal cirri, 12 dorsal kineties, mid-dorsal kinety with 21 -25 dorsal bristles; silver-line system double-eurystomus type. D. oligothrix: size in vivo about $80-90\times30-70{\mu}m$; body shape ovoid with prominent right concave posterio-lateral end, two irregular elongated macronuclei with one micronucleus, respectively; 7 fronto-ventral, 5 transverse, 2 left marginal and 2 caudal cirri, 4 dorsal kineties with prominent bristles about $9-14{\mu}m$ long in vivo.

Design of In-situ Self-diagnosable Smart Controller for Integrated Algae Monitoring System

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Shin, Jaekwon;Yang, Seungyoun
    • International Journal of Advanced Culture Technology
    • /
    • v.5 no.1
    • /
    • pp.64-69
    • /
    • 2017
  • The rapid growth of algae occurs can induce the algae bloom when nutrients are supplied from anthropogenic sources such as fertilizer, animal waste or sewage in runoff the water currents or upwelling naturally. The algae blooms creates the human health problem in the environment as well as in the water resource managers including hypoxic dead zones and harmful toxins and pose challenges to water treatment systems. The algal blooms in the source water in water treatment systems affects the drinking water taste & odor while clogging or damaging filtration systems and putting a strain on the systems designed to remove algal toxins from the source water. This paper propose the emerging In-Situ self-diagnosable smart algae sensing device with wireless connectivity for smart remote monitoring and control. In this research, we developed the In-Site Algae diagnosable sensing device with wireless sensor network (WSN) connectivity with Optical Biological Sensor and environmental sensor to monitor the water treatment systems. The proposed system emulated in real-time on the water treatment plant and functional evaluation parameters are presented as part of the conceptual proof to the proposed research.

Efficient Dewatering of the Sewage Sludge by Electrodewatering System (전기탈수방법에 의한 하수 슬러지 탈수 특성)

  • Park, Chan-Jung;Lee, Jung-Eun;Ahn, Young-Chull;Shin, Hee-Soo;Lee, Jae-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.526-531
    • /
    • 2000
  • Application of electrodewatering (EDW) to mechanical dewatering system was studied to decrease water content in the sludge generated from waste water treatment process. Experiments realized the reduction of water content in the sewage sludge. EDW enhancing the conventional filtration by an electric field is an emerging technology with the potential to improve dewatering. In this study, a piston filter press was constructed, the digested sludges were dewatered by EDW under conditions of DC electric field and constant pressure in the piston filter press. Constant electric field from $0{\sim}120\;V/cm$ and constant pressure $98.1{\sim}392.4\;kPa$ were used. The results showed that as electric field was increased the dewatering rates increased and as pressure was increased the dewatering rates decreased. Also as polymer was added the dewatering rates increased. This experiments produced final sludge cake with water content of 60 wt% using EDW, compared with 80 wt% using pressure filtration alone.

  • PDF

Development of an environmentally friendly precipitation treatment system utilizing open space in residential estates (주거단지의 외부공간을 활용한 친환경적 우수처리 시스템 개발)

  • Lee, Eun-Heui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.3
    • /
    • pp.55-65
    • /
    • 2001
  • The hydrological cycle system in the city is generally characterized by quick runoff, bad infiltration, low evaporation rate, and so on. It is caused by sealing greens up with pavements. Also, there are lots of contradictory environmental problems, such as inundation, the lack of underground water and dryness in the city, caused by the urban drainage system which is mostly focused on the quick draining off rainfall. In addition, the technique joining rain and sewage, which has more dangers of inundation, occupies 66% between two Korean drainage systems which consist of joining and dividing system. There has been some need to convert the present drainage system into the environmentally friendly hydrological cycle system. This is a theoretical study to examine some foreign cases and suggested applicable methods in our country, focusing on the environmentalyl friendly system of rainfall drainage. The precipitation treatment system can be made up of some possible phases choosing from premanagement, utilization, infiltration, retention, and inducement phases. Therefore, this study mostly focused on infiltration, retention, and inducement phases. It is necessary to suggest the multifunctional utilization of outdoor spaces, especially applying in new constructing and re-constructing residential estates.

  • PDF

Selection of Optimum Water Plant in Constructed Wetland by Natural Purification Method for Municipal Sewage Treatment (자연정화공법에 의한 인공습지 하수처리장에서 최적 수생식물의 선정)

  • Seo, Dong-Cheol;Jang, Byeong-Il;Jo, In-Seong;Lim, Seok-Cheon;Lee, Hong-Jae;Cho, Ju-Sik;Kim, Hong-Chul;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.1
    • /
    • pp.25-33
    • /
    • 2006
  • Objectives of this experiment were to select of the optimum water plant and to investigate the removal efficiency of the major nutrients in the constructed wetland by natural purification method for municipal sewage treatment in the farming and fishing village. For the experiment we used "constructed wetland" which was consisted of aerobic (vertical filter system) and anaerobic systems (horizontal filter system). Both systems were filled with gravel and filter media, and grew water plants on top of them. And then, we investigated several items such as sewage treatment efficiency, growth status of water plants and the absorbed amount of inorganic element in water plants with periodical periods. In aerobic area, removal efficiencies of BOD, COD, T-N and T-P were over 92%, 74%, 25% and 57%, respectively, and then when the water is passed through anaerobic area, the efficiency was over 96%, 84%, 44% and 71%, respectively, which was increased more treatment efficiency than that of aerobic area. Absorption amount of nitrogen and phosphorous in Miscanthus sacchariflorus BENTH were the highest in the water plants as 17.7 and 2.41 g/plant in the aerobic area, respectively. Absorption amounts of nitrogen and phosphorous in Scirpus tabernaemontani GMEL were the highest in the water plants as 8.7 and 1.13 g/plant in the anaerobic area, respectively. For the selection of optimum water plants in the constructed wetland by natural purification method for municipal sewage treatment, it were observed that there were Miscanthus sacchariflorus BENTH, Phragmites japonica STEUD and Phragmites communis TRINIUS in the aerobic area and were Zizania latifolia TURCZ, Scirpus tabernaemontani GMEL, Typha orientalis PRESL, Iris pseudoacorus L and Cares dispalata BOOTT in the anaerobic area.

Operation diagnostic based on PCA for wastewater treatment (PCA를 이용한 하폐수처리시설 운전상태진단)

  • Jun Byong-Hee;Park Jang-Hwan;Chun Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.3
    • /
    • pp.383-388
    • /
    • 2006
  • SBR is one of the most general sewage/wastewater treatment processes and, particularly, has an advantage in high concentration wastewater treatment like sewage wastewater. A Kernel PCA based fault diagnosis system for biological reaction in full-scale wastewater treatment plant was proposed using only common bio-chemical sensors such as ORP(Oxidation-Reduction Potential) and DO(Dissolved Oxygen). During the SBR operation, the operation status could be divided into normal status and abnormal status such as controller malfunction, influent disturbance and instrumental trouble. For the classification and diagnosis of these statuses, a series of preprocessing, dimension reduction using PCA, LDA, K-PCA and feature reduction was performed. Also, the diagnosis result using differential data was superior to that of raw data, and the fusion data show better results than other data. Also, the results of combination of K-PCA and LDA were better than those of LDA or (PCA+LDA). Finally, the fault recognition rate in case of using only ORP or DO was around maximum 97.03% and the fusion method showed better result of maximum 98.02%.

Pilot Study on the Advanced Treatment of Combined Wastewater with Sewage as a Cosubstrate (가정하수를 cosubstrate로서 사용한 하수-염색폐수-공장폐수의 합병 고도처리 pilot plant 연구)

  • Kim, Mee-Kyung;Seo, Sang-Jun;Rhew, Doug-Hee;Jung, Dong-Il
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.227-234
    • /
    • 2009
  • In this research, a retrofitting process, which consists of a pretreatment system (coagulation) for dye wastewater combined with a biological nutrient system (MLE process using media), for a sewage treatment plant that has to treat dye wastewater efficiently with domestic wastewater were developed and a pilot plant was operated for verifying adoptability and performance of the developed advanced process for dye wastewater. From the results of the pilot plant operation, BOD 52.9%, $COD_{Cr}$ 55.9%, and color 71.3% were removed in pretreatment of coagulation process and the biodegradability of dye wastewater was improved to $0.32{\sim}0.59BOD/COD_{Cr}$ of the coagulated wastewater from $0.29{\sim}0.43BOD/COD_{Cr}$ of the raw dye wastewater. The final effluent concentrations were BOD of 8 mg/L, $COD_{Cr}$ of 43 mg/L, $COD_{Mn}$ of 18 mg/L, T-N of 8 mg/L, and T-P of 1.3 mg/L, respectively. Color was removed from 1655 to 468 unit by coagulation and then to 123 unit by MLE process. The HPLC analysis of aromatic amines in wastewater showed that decolorization was achieved by cometabolism while aromatic amines were produced by cleavage of azo bonds under anaerobic conditions and these products were removed in an aerobic tank subsequently. Nitrification rates of attached and suspended microorganisms were evaluated comparatively and the acclimating conditions of bacteria on media were validated by the scanning electron microscope.

Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB) (간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성)

  • Huh, Mock;Kang, Jin-Yuong;Kim, Gwang-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.125-131
    • /
    • 2003
  • This study was carried out to develop INSUB(Indirected Aerated Submerged Biofilter) which can remove organics, nitrogen and phosphorus with an advanced treatment system. The results were as followed in laboratory model experiment. As for treatment of sewage, when economical efficiency was considered in practice, the highest removal efficiency was at 18hr of HRT, 1.017m/hr of superficial velocity and 40% of media packing ratio. Each removal efficiency for $COD_{cr}$, $COD_{Mn}$, $BOD_5$, T-N, and T-P was 90.6, 85.3, 95.0, 52.3 and 56.8%. To remove the nitrogen and phosphorus With high efficiency, first of all, denitrification have to be completed, then uptake of phosphorus have to completed. Therefor, mixture of anoxic and aerobic reactor was necessary for the high removal efficiency of nitrogen and phosphorus in INSUB.

  • PDF

Removal of Organic Matter, Nitrogen and Phosphorus in an UASB Sewage Treatment Process with Recycle of Aerated Bio-Filter Effluent (UASB를 이용한 혐기성 하수처리공정에서 ABF 유출수 반송에 따른 유기물질과 질소 및 인 제거)

  • Tian, Dong-Jie;Byun, Byeong-Su;Lim, Hyun-Suk;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.381-387
    • /
    • 2013
  • Nitrogen and phosphorus removal was investigated in an UASB-ABF (Up-flow anaerobic sludge blanket - aerated bio-filter) anaerobic sewage treatment system. Successful removal of nitrogen and phosphorus with organic matters was possible in the UASB-ABF system from the results of 160 days operation with the influent raw domestic sewage. Removal efficiencies of organic matter (as TCOD) showed 64% in UASB without recycle of the ABF effluent, however, they increased to 92%, 95%, 96% with 120%, 180% and 240% recycle of the ABF effluent, respectively. Increasement of the organic matter removal was not prominent at recycle ratio above 180%. Apparent increase in TN removal occurred with recycle of the ABF effluent. TN removal efficiency was 18% without recycle, but it increased to 82% with 240% recycle of the ABF effluent. And stable nitrification above 95% was possible as a result of efficient removal of organic matter in the UASB with and without recycle of the effluent. Removal of both TP and $PO{_4}^{3-}$-P also increased remarkably with recycle of the effluent. Without recycle of the effluent, that is at strict anaerobic condition in UASB, TP was not removed, however, its removal efficiency increased to 51%, 63%, 71% at recycle ratios of 120%, 180%, 240%, respectively mainly at UASB.

An Experimental Study for Practical Application of RBC (RBC의 실제적용(實際適用)을 위한 실험연구(實驗硏究))

  • Kim, Hee-Jeong;Ahn, Yong-Tae
    • Korean Journal of Environmental Agriculture
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 1985
  • Recently the method using fixing biological contactor in treatment of sewage and wastewater has been propelling on the ground that it has advantages of reducing both motive and man power and applied treatment plants of this method are increasing gradually in Korea. After analysing the results from which real structure pilot plant had operated in the field with RBC sewage wastewater system-one of the fixing biological contact methods-for five months, this study was performed to investigate how to apply the standard of establishment that provided in article of sewage disposal facilities notified (act 8 of art 84) by the office of environment on May 16, 1984, to real treatment plant. The rotating velocity and the staying time of rotating disc have interrelation on removal efficiency of BOD. When circumferential velocity of rotating disc was ranged from 18 to 20 m per minute, economical price was the best. When the staying time was even about 120 minutes for that of home RBC facilities showed 90% or above of BOD removal efficiency of high concentration sewage also showed excellent efficiency ranged from about 85% to 90%.

  • PDF