• Title/Summary/Keyword: Sewage treatment system

Search Result 372, Processing Time 0.027 seconds

Assessment on Economies-Environmental Affect of Smart Operation System(SOS) in Sewage Treatment Plant (실증규모 하수처리장에 적용된 스마트 운영시스템의 경제-환경적 기여도 평가)

  • Kim, Younkwon;Seo, InSeok;Kim, Hongsuck;Kim, Jiyeon
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.581-589
    • /
    • 2013
  • Generally, Sewage Treatment Plants(STPs) are complexes systems in which a range of physical, chemical and biological processes occur. However, their performance strongly depends on the know-how acquired by the field-engineer. Recently, in order to solve this situations, various operation and management technologies based on the Instrumentation, Control and Automation(ICA) have been developed. As a economies-environmental affect point of view, this study was for the performance evaluation and assessment of results from the Smart Operation System(SOS) in full-scale STP. The SOS in STP consisted of the process monitoring module, including real-time influent prediction and effluent simulation, and the Smart Air Control(SAC) module. According to the results from field test for 2 years, the results of economical evaluation, amount of benefits and cost saving by the SOS have shown to be much higher than that of traditional operation. Nevertheless, the removal load(kg/yr) of BOD 13.3 %, COD 28.2 %, TN 44.4 % and TP 20.8 % were increased, respectively. Remarkable improvement of removal load could be achieved after the SOS was adapted. It was concerned that the SOS offer a user friendly functionalities and cost saving needed by the field-engineers. In addition, it was expected that the results of this study would supply helpful information for design and cost saving for the SOS in full-scale STP.

Study on the Co-firing of Sewage Sludge to a 80 kWth-scale Pulverized Coal Combustion System (80 kWth급 미분탄 연소 시스템에서 하수슬러지 혼소시 연소 특성 연구)

  • Chae, Taeyoung;Lee, Jaewook;Lee, Youngjae;Yang, Won
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.74-80
    • /
    • 2019
  • Thermochemical treatment of sewage sludge is an energy-intensive process due to its high moisture content. To save the energy consumed during the process, the hydrothermal carbonization process for sewage sludge can be used to convert sewage sludge into clean solid fuel without pre-drying. This study is aimed to investigate co-firing characteristics of the hydrothermally carbonated sewage sludge (HCS) to a pulverized coal combustion system. The purpose of the measurement is to measure the pollutants produced during co-firing and combustion efficiency. The combustion system used in this study is a furnace with a down-firing swirl burner of a $80kW_{th}$ thermal input. Two sub-bituminous coals were used as a main fuel, and co-firing ratio of the sewage sludge was varied from 0% to 10% in a thermal basis. Experimental results show that $NO_x$ is 400 ~ 600 ppm, $SO_x$ is 600 ~ 700 ppm, and CO is less than 100 ppm. Experimental results show that stable combustion was achieved for high co-firing ratio of the HCS. Emission of $NO_x$ and $SO_x$ was decreased for higher co-firing ratio in spite of the higher nitrogen contents in the HCS. In addition, it was found that the pollutant emission is affected significantly by composition of the main fuel, regardless of the co-firing ratios.

Reuse Methods of Treated Sewage for securing Water Resource in Busan (부산시 수자원 확보를 위한 하수처리수 재이용 방안)

  • Kim, Jung-Bae;Moon, Seung-Gun;Park, Yool
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1232-1237
    • /
    • 2009
  • Recently, we often encounter water shortage problem due to drought during dry season. Although we have built dams and expanded our tap water system greatly to meet the increasing demand of water, this approach has its inherent limitation including environmental destruction in the course of the dam construction. Therefore, this paper is aimed to analyze the water recycling models developed in other countries and modify them to fit into our system. Also the water recycling system in Busan municipal area was analyzed to propose an alternative method for reusing the recycled water from wastewater treatment area.

  • PDF

The Study of Advanced Treatment of Sewage Wastewater by the Electro Coagulation and Oxidation System (전기응집산화를 이용한 하수처리장의 고도처리방안 연구)

  • Lim, Jin-Hwan
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.556-562
    • /
    • 2018
  • Due to the enforcement of effluent water regulation the advance sewage treatment system is needed to retrofit and remodelling. In this case the most important issue is the effluent concentrations of TP and there are a lot of system to reduce its concentration. But biological treatment processes have many restrictions to enhance the removal efficiency of TP. In this study the efficient ECO operating condition to improve and retrofit biological sewage wastewater treatment system is as follow; 1) The treatment efficiency of BOD, TN and TP at the current density of $15mA/cm^2$ was higher than the treatment efficiency at $5mA/cm^2$ in the electrodes arranged with Al-SUS(Stainless Steel) regardless of the reaction time, The TP concentration was 0.1 mg/L or less. Especially, when the reaction time was maintained at 10 min, the TP concentration was 0.06 mg/L or less irrespective of the current density. 2) The change of TP concentration is not influenced by the change of current density and rather the concentration of treated water changes according to the reaction time. In the case of electro coagulation reaction, a few seconds to several minutes are required. However, the reaction time of electro coagulation and oxidation was studied to be more than 10 minutes. 3) As a result, it has been studied that the economical current density of the electro coagulation oxidation process for TN and TP treatment of domestic wastewater is $15mA/cm^2$ or less and the reaction time is 10 minutes.

Automatic T-P Coagulation Control System using an EC in the MSBR Process - Full Scale Study - (MSBR 공정에서 전기전도도를 이용한 인 제거 자동제어시스템 - 현장 적용 중심 -)

  • Jang, Hee-seon;Lee, Ho-sik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.90-96
    • /
    • 2017
  • Many sewage treatment plants have applied the advanced technology of chemical coagulant system to remove phosporus in Korea. However there are some problems for the injection of optimum coagulant dosage. In order to solve these problems, the research related to the more cost-effective automatic total phosphorus coagulation control system using an EC(Electrical Conductivity) have been in progress. This study was conducted by the same process and operation method as the Lab-scale for public small town sewage treatment plant. First, it confirmed the correlation among the EC, PO4-P and coagulant dosage in the Lab-scale MSBR(Membrane Sequencing Batch Reactor) process. Next, it analyzed that correlation coefficient of EC and the coagulant dosage was 0.92 in the Full-scale MSBR process. As a result, not only T-P removal efficiency was doubled but also it satisfied the effluent water quality standard in a stable manner. In addition, by applying the automatic control system using the EC, compared to the fixed coagulant injection system the coagulant dosage could be reduced by 28%.

Constructing the Operating Information System(OIS) and Improving the Water Quality by OIS in Water Treatment Plants (수도시설 운영정보화 시스템 구축 및 효율개선효과)

  • Oh, Jung-Woo;Song, Yoon-Seob;Kang, Geum-Bai;Yoo, Man-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.699-705
    • /
    • 2007
  • In this study, the improvement of the operation condition and the water quality in water treatment plant by operating information system(OIS) was evaluated for Ansan water treatment plant. The average flow rate of raw water in the year 2005(after constructing the OIS) appeared 15.6 % lower than that in the year 2004(before constructing the OIS). The mean value(12.37 NTU) of raw water turbidity in the year 2005 remained constant, or nearly so with that(12.06 NTU) in the year 2004. The average dosing rates of coagulant appeared 12.06 mg/L in the year 2005 which was higher than 10.31 mg/L in the year 2004. Furthermore, the average turbidity concentration of fresh water in the year 2005 appcared slightly better than that in the year 2004. From $COD_{Mn}$ and BOD concentration of raw water, the water quality in the year 2005 were better than those in the year 2004. The average concentration of $KMnO_4$ in the year 2004 and the year 2005 was 2.95 mg/L and 1.25 mg/L, respectively, and the average concentration of THMs in the year 2004 and the year 2005 appeared 0.038 mg/L and 0.025 mg/L, respectively. Therefore, the fresh water quality in the year 2005 was better than that in the year 2004. In this study, it is considered that the operation of Ansan water treatment plant may be optimized by OIS, and thus the OIS may be very useful method to improve the water quality.

Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment (소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가)

  • An, Jin-Young;Kwon, Joong-Chun;Kim, Yun-Hak;Jeng, Yoo-Hoon;Kim, Doo-Eon;Ryu, Sun-Ho;Kim, Byung-Woo
    • Clean Technology
    • /
    • v.12 no.2
    • /
    • pp.67-77
    • /
    • 2006
  • A simple dual sludge process, called as $KNR^{(R)}$ (Kwon's Nutrient Removal) system, was developed for small sewage treatment. It is a hybrid system that consists of an UMBR (Upflow multi-layer bioreactor) as anaerobic and anoxic reactor with suspended denitrifier and a post aerobic biofilm reactor, filled with pellet-like media, with attached nitrifier. To evaluate the stability and performance of this system for small sewage treatment, the pilot-scale $KNR^{(R)}$ plant with a treatment capacity of $50m^3/d$ was practically applied to the actual sewage treatment plant, which was under retrofit construction during pilot plant operation, with a capacity of $50m^3/d$ in a small rural community. The HRTs of a UMBR and a post aerobic biofilm reactor were about 4.7 h and 7.2 h, respectively. The temperature in the reactor varied from $18.1^{\circ}C$ to $28.1^{\circ}C$. The pilot plant showed stable performance even though the pilot plant had been the severe fluctuation of influent flow rate and BOD/N ratio. During a whole period of this study, average concentrations of $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, and TP in the final effluent obtained from this system were 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, and 0.87/0.17 mg/L (with/without poly aluminium chloride(PAC)), which corresponded to a removal efficiency of 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, and 55.4/90.3%, respectively. Excess sludge production rates were $0.026kg-DS/m^3$-sewage and 0.220 kg-DS/kg-BOD lower 1.9 to 3.8 times than those in activated sludge based system such as $A_2O$ and Bardenpho.

  • PDF

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

A Study on Reuse of Reclaimed Water in Jeonbuk Province (전북지역 하수처리수 재이용 방안 연구)

  • Cho, Changwoo;Kim, Jintae;Park, Jeongjae;Song, Juhoon;Lee, Miseon;Jeong, Juri;Ryou, Jaewoong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.237-245
    • /
    • 2017
  • This study was aimed at investigating effluent water quality and proposing reuse possibilities for 12 sewage treatment plants discharged more than $5,000m^3/day$ in order to recycle the sewage treatment plant effluent of Jeollabuk-do effectively. Additionally, a laboratory scale test for reprocessing water discharge was performed. Categories of reclaimed sewage water reuse were divided into 7 topics and analyzed a total of 28 items including 16 heavy metals based on water quality standard. As a results, color, BOD, TN, chloride and Electrical Conductivity (EC) exceeded reused water quality standard. In particular, color and TN exceeded in 8 and 5 sewage treatment plants, respectively. The value of chloride and EC were high in sewage treatment plants including the food and industrial wastewater. At 4 sewage treatment plants were possible to reuse without re-treatment. The laboratory scale test was conducted to SandFilter (SF)-Granular Activated Carbon (GAC)-MicroFiltraion (MF)-Reverse Osmosis (RO). Both the removal efficiencies and economic feasibility of total E. coli., color and Suspended Solid (SS) suited in case using the SF-GAC treatment method. The removal of chloride and EC had little effect in the case of SF-GAC-MF system, but RO showed over 90% of removal efficiency. After using SF-GAC process only, the concentration of $UV_{254}$ decreased sharply from 0.3651 /cm to 0.0306 /cm and it showed over 92% of removal efficiency rate. In conclusion, for the effective reuse of sewage discharged water, water quality and the surrounding terrain of treatment plants should be all taken into account. If it needed for the reprocessing, both the selection for treatment and economic combination treatment methods will have to be considered.

The System of Sewage and Domestic Wastewater Treatment Plants in Tan-Sui River Basin

  • Ko, Chun-Han
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.26.2-39
    • /
    • 2002
  • Tan-Sui River Basin covers Taipei metropolitan area of 2,726 square kilometers with more than six million residents. Since 1988, Taiwan government started to plan and construct an integrated sewerage system, consisted by both separated and concentrated trunk sewers, wastewater treatment plants and ocean outfalls. This presentation will introduce the master plan and major facilities of Tan-Sui River Basin sewerage system. Other measures to protect general water quality and the environment of adjacent river basin area of Tan-Sui River and her tributaries by Taiwan EPA will be presented as well.

  • PDF