• Title/Summary/Keyword: Sewage pipeline

Search Result 24, Processing Time 0.03 seconds

A Study on Applicability of Water Pipe Detecting Using GPR (상수관로 탐사에 대한 지중레이더의 적용가능성에 관한 연구)

  • Lee, Won-Jong;Lim, Sung-Min;Choi, Yun-Soo;Min, Kwan-Sik
    • Journal of Cadastre & Land InformatiX
    • /
    • v.45 no.2
    • /
    • pp.131-147
    • /
    • 2015
  • In modern society, as to the underground urban infrastructure facilities(communication electricity water and sewage gas etc.) were contained many risks because of excavating. The exact position of underground facilities and the attribute information should be built in order to prevent accidents. As the result of analyzing the public surveying results from 2004 to 2009, it shows that low detecting rate of water pipeline which is only 52.4%, because the exploration of electromagnetic induction only detect metal pipeline and positioning survey only detect new pipeline before burying. Therefore development and verification of the correct and efficient exploration techniques are needed to improve the detecting rate. In this study, determined based on the location measurement results for the non-metal pipes and metal pipes before burial. It was compared with values that obtained through the ground penetrating radar and electromagnetic induction detecting. As a result, detecting rate of the concrete section showed a 100%, unpaved section showed a 94.7%, asphalt section showed 60%. So it confirmed the applicability of the ground penetrating radar at underground facilities detecting.

The Development of Cleaning and Monitoring System for Pipeline Type UV Sterilizer (관로형 UV 소독기를 위한 세척 및 모니터링 시스템 개발)

  • Park, Byeung-Jun;Ryu, Ji-Hyoung;Park, Jae-Byung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6434-6440
    • /
    • 2013
  • In this paper, an integrated control system is proposed for automatic control and remote monitoring of pipeline type UV sterilizer. The proposed system can control the cleaning wiper in the sterilizer with various cleaning motions, and periodically check the contamination level of the UV lamps with the UV power sensors. Therefore, sterilizer repair and maintenance can be more effectively done. In addition, the control system based on the open-source processor can communicate with external smart devices via Bluetooth, and thus wirelessly exchange control commands and sensor data. Furthermore, the system is able to flexibly cope with changes of cleaning motions and sensors since its firmware can be wirelessly upgraded by using the smart device. Consequently, the proposed system is suitable to construct a smart sewage treatment system in small towns.

Correlation Analysis of the Occurrence of Ground Subsidence According to the Density of Underground Pipelines (지중관로 매설 밀집도에 따른 지반함몰 발생 상관 분석)

  • Kim, Jinyoung;Kang, Jaemo;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.11
    • /
    • pp.23-29
    • /
    • 2021
  • Recently, ground subsidence has been steadily occurring mainly in downtown areas, threatening the safety of citizens. Under the road, various underground facilities such as water supply pipe, sewage pipe, and communication pipe are buried. Due to the aging of these underground facilities and the reckless development of the underground, it is acting as a cause of ground subsidence. Although there is a result of analyzing the risk of ground subsidence according to the deterioration of the existing pipeline, there is no result of analyzing the risk of ground subsidence using the density of pipelines indicating ground disturbance. Therefore, in this study, the density of the underground space was analyzed using the data of six types of representative underground pipelines in Seoul, and a study was conducted on whether there is a correlation with the ground subsidence. As a result, it was found that the density of underground facilities is high in the area where the ground subsidence occurred, indicating that the density of pipelines have an effect on the ground subsidence.

Design Flow Velocity Changes According to the Design Flow Determination Methods in the Sanitary Sewer (오수관 설계유량 산정법이 설계유속에 미치는 영향)

  • Hyun, In-hwan;Won, Seung-hyun;Kim, Hyung-jun;Lee, Che-in
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.749-757
    • /
    • 2005
  • The present study analyzed actual cases of designed flow estimation method and designed flow rate of sewage pipe lines. In order to examine the effects of peak-hour demand factor estimation with given daily highest peak loading, we analyzed its effects on designed flow rate with changing the peak-hour demand factor from 2.0 to 10.0. The results of this study are as follows. When reviewing the recent designs, we found that 59.4% of pipe line with 250mm and 300mm diameter, which fall under minimum allowable pipeline did not meet the minimum velocity which is specified as 0.6m/sec in design standards. The pipe line that have minimal access population or have very low slope did not satisfy the minimum velocity. In estimating the designed sewage flow, the applied daily highest peak loading and hourly highest peaking loading were the load factor for the entire population of the planned area, and for the peak loading of the initial pipes connected to a very small population, we applied the same factor as that applied to the entire area and, as a result, the hourly highest flow was underestimated. Because, in case of the initial pipes, the method of applying the same peak loading to all subject areas is highly possible to produce underestimated design flow, when estimating the designed flow of the initial pipes connected to a small population need to adopt a rational flow factor according to the size of population. For this, it is considered to investigate and analyze raw data on daily and hourly variation of sewage flow.

A study of struvite control using CO2 in sewage treatment process (하수처리공정에서 이산화탄소를 이용한 스트러바이트 제어에 관한 연구)

  • Han, Keumseok;Hong, Seongho;Choi, Youngjune
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.261-268
    • /
    • 2018
  • Sludge transporting pipes in wastewater treatment plant are easy to be clogged with struvite when the digested sludge and dehydrated filtrate are transported through the pipes, which lowers the efficiency of sludge treatment system in a WWTP. pH is one of the most important factors in struvite formation, and carbon dioxide separated from biogas can be used to control pH and struvite formation. By controlling pH, the amount of dehydrating agent can be reduced by about 10%, which saves the budget for facility maintenance. As $CO_2$ is reused and dehydrating chemicals are saved, the approach can contribute to global warming gas reduction.

Material Properties of Ultra Rapid Hardening Mortar for Repairing Sewage Treatment Concrete Pipes (콘크리트 하수관거 보수용 초속경 수중불분리 모르타르의 재료적 특성)

  • Lee, Byungjae;Lee, Sunmok;Bang, Jin-wook;Kim, Yun-yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.57-62
    • /
    • 2020
  • Among the sewage pipes installed in Korea, the length of concrete pipes exceeding 20 years is 66,334 km (42.5%). Deteriorated concrete sewer pipes need to be repaired due to the leakage of internal sewage, which causes problems such as sink holes by expanding the cavity around the pipeline. In this study, we tried to apply anti-washout underwater mortar with ultra rapid hardening cement and segregation reducing agent to sewage pipe repair. As a result of the setting time test, the final set time was delayed by up to 172% by incorporating segregation reducing agent. In the test for measuring the degree of mortar segregation in water, it was measured at pH 12 or less under all mixing conditions. In addition, the suspension amount was measured to be 50 mg / l or less to satisfy the KCI-AD102 standard by incorporating a segregation reducing agent. In terms of the average value of mortar compressive strength, by incorporating segregation reducing agent, the strength of the specimens produced in air was more than 80% of that of the specimens produced in water. Conversely, the bond strengths of the specimens produced in water were measured to be higher than those of the specimens produced in air. Water resistance was evaluated by measuring water absorption and water permeability. Water absorption and water permeability were reduced by 42.6% and 36.6%, respectively, by mixing segregation reducing agent.

The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data (유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안)

  • Kim, Yunha;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.

Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles (토목 발파가 소음, 진동, 부유 분진에 미치는 영향)

  • Jeong, Jin Do;Jeong, Yeong Guk
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.

Image Processing Algorithm for Crack Detection of Sewer with low resolution (저해상도 하수관거의 균열 탐지를 위한 영상처리 알고리즘)

  • Son, Byung Jik;Jeon, Joon Ryong;Heo, Gwang Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.590-599
    • /
    • 2017
  • In South Korea, sewage pipeline exploration devices have been developed using high resolution digital cameras of 2 mega-pixels or more. On the other hand, most devices are less than 300 kilo-pixels. Moreover, because 100 kilo-pixels devices are used widely, the environment for image processing is very poor. In this study, very low resolution ($240{\times}320$ = 76,800 pixels) images were adapted when it is difficult to detect cracks. Considering that the images of sewers in South Korea have very low resolution, this study selected low resolution images to be investigated. An automatic crack detection technique was studied using digital image processing technology for low resolution images of sewage pipelines. The authors developed a program to automatically detect cracks as 6 steps based on the MATLAB functions. In this study, the second step covers an algorithm developed to find the optimal threshold value, and the fifth step deals with an algorithm to determine cracks. In step 2, Otsu's threshold for images with a white caption was higher than that for an image without caption. Therefore, the optimal threshold was found by decreasing the Otsu threshold by 0.01 from the beginning. Step 5 presents an algorithm that detects cracks by judging that the length is 10 mm (40 pixels) or more and the width is 1 mm (4 pixels) or more. As a result, the crack detection performance was good despite the very low-resolution images.

Cause Analysis for Reduced Effect of Sewer Pipe Improvement Project Based On Investigation of Interceptor Sewers (차집관로의 조사 및 분석을 통한 하수관로정비 사업의 효과 감소 원인 분석)

  • Chae, Myungbyung;Bae, Younghye;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.219-226
    • /
    • 2018
  • Interceptor sewer is installed underground near to the river side mostly ofstate-owned land and the management efficiency of public sewage disposal facilities is decreasing as too much infiltration/inflow(I/I) and river flow to interceptor sewer are caused by broken or deteriorated sewer. This also affects the sewer pipeline project and decreases its efficiency. Therefore, the aim of this study is to investigate interceptor sewer which has influence on the reduction of the project effect. The investigation were performed for three study areas. The study includes the investigation of current condition of interceptor sewer(sewer extension, pipe diameter, pipe type, installed year, installed locations, etc), investigation of inside of sewer by CCTV accompanied by pumping and dredging works where required, investigation of inside of manholes by eyes, calculation of pollutant load using the results of investigation of flow quantity and quality. Multipoint investigations were simultaneously performed for flow quantity at confluence area and other investigations were also performed for flow quantity and BOD for interceptor sewer and comparison of pollutant load, investigation of infiltration/inflow(I/I) caused by deterioration of interceptor sewer. As the result of the study, a main reason for reduced effect of sewer pipe improvement project was analyzed as the low-density sewage and I/I in public seweage treatment Facility due to deteriorated and unmanaged interceptor sewers.