• Title/Summary/Keyword: Sewage effluent

Search Result 340, Processing Time 0.023 seconds

Identification of pollutant sources using water quality and stable isotope ratios of inflow tributaries in the lower reaches of the Han-River

  • Hong, Jung-Ki;Lee, Bo-Mi;Son, Ju Yeon;Park, Jin-Rak;Lee, Sung Hye;Kim, Kap-Soon;Yu, Soon-Ju;Noh, Hye-ran
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.65-76
    • /
    • 2019
  • Despite the expansion of sewage treatment facilities to reduce pollutants in the tributaries of the Han River, water pollution accidents such as fish deaths continue to frequently occur. The purpose of this study was to identify the pollutant sources using water quality and stable isotope ratio (${\delta}^{15}N$, ${\delta}^{13}C$, ${\delta}^{15}N-NH_4$, ${\delta}^{15}N-NO_3$) analysis results in the three inflow tributaries (Gulpocheon (GP), Anyangcheon (AY) and Sincheon (SC)) of the Han River. Water quality was analyzed in June and October from 2013 to 2017, and the results showed that the concentrations of nutrients, such as T-N, $NO_3-N$, and T-P, were increased at GP4, AY3, SC3, and SC4, which lie downstream of sewage treatment facilities. The results of ${\delta}^{15}N$ for June 2017 indicated that the source of nitrogen was sewage or livestock excreta at GP4 and SC4, and organic fertilizers at AY3 and SC3. ${\delta}^{15}N-NO_3$ results suggested that the source of nitrogen was related to organic sewage, livestock or manure at GP4, AY3 and SC4. Therefore, GP4 and SC4 were more influenced by effluent from sewage treatment facilities than by their tributaries, AY3 and SC3 were considered to be influenced more by their tributary than effluent from sewage treatment facilities. With the results of this study, the source of contamination (sewage treatment facility effluent) of river inflow downstream of Han River could be confirmed using water quality and stable isotope ratio.

Advanced Oxidation Processes of Secondary Effluent for Reuse (재사용을 위한 하수처리장 방류수의 고급산화처리)

  • 조일형;송경석;성기석;정문호;이홍근;조경덕
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.61-68
    • /
    • 2000
  • The use of photo-catalytic processes in pollution abatement and resource has a significant economic importance. Therefore, the applications of photochemical oxidation of secondary effluent driven by UV, TiO2, TiO2/UV, H2O2/UV and TiO2/H2O2/UV, have been investigated in order to treat the secondary effluent from municipal sewage. Various experimental parameters such as BOD, CODcr, Nurbidity, total P, and SPC were examined in each photo-catalytic reaction system. The results showed that the application of single oxidant such as UV, TiO2 only has a minor effect on parameters reduction (CODcr, BOD, etc) to treat the secondary effluent, whereas the combinations of oxidants increase the removal efficiency. The best removal efficiency in every parameters was achieved by the combination of TiO2, H2O2 and UV. It was also found that the optimum amount of TiO2 for the treatment was 1g/ι to achieve water reuse standard. From the results, the photocatalytic reaction system can be an alternative as a post-treatment to treat the secondary effluent from municipal sewage.

  • PDF

Removal of Organic Matter, Nitrogen and Phosphorus in an UASB Sewage Treatment Process with Recycle of Aerated Bio-Filter Effluent (UASB를 이용한 혐기성 하수처리공정에서 ABF 유출수 반송에 따른 유기물질과 질소 및 인 제거)

  • Tian, Dong-Jie;Byun, Byeong-Su;Lim, Hyun-Suk;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.381-387
    • /
    • 2013
  • Nitrogen and phosphorus removal was investigated in an UASB-ABF (Up-flow anaerobic sludge blanket - aerated bio-filter) anaerobic sewage treatment system. Successful removal of nitrogen and phosphorus with organic matters was possible in the UASB-ABF system from the results of 160 days operation with the influent raw domestic sewage. Removal efficiencies of organic matter (as TCOD) showed 64% in UASB without recycle of the ABF effluent, however, they increased to 92%, 95%, 96% with 120%, 180% and 240% recycle of the ABF effluent, respectively. Increasement of the organic matter removal was not prominent at recycle ratio above 180%. Apparent increase in TN removal occurred with recycle of the ABF effluent. TN removal efficiency was 18% without recycle, but it increased to 82% with 240% recycle of the ABF effluent. And stable nitrification above 95% was possible as a result of efficient removal of organic matter in the UASB with and without recycle of the effluent. Removal of both TP and $PO{_4}^{3-}$-P also increased remarkably with recycle of the effluent. Without recycle of the effluent, that is at strict anaerobic condition in UASB, TP was not removed, however, its removal efficiency increased to 51%, 63%, 71% at recycle ratios of 120%, 180%, 240%, respectively mainly at UASB.

Manufacturing and Characteristics of the Electrodeless UV Lamp for Disinfection of the Sewage Effluent (하수 방류수 살균소독을 위한 무전극 UV 램프의 제조 및 특성)

  • Shin, Dong Ho;Lee, Yong Taek
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.570-575
    • /
    • 2005
  • In this study, we have manufactured electrodeless ultraviolet lamp which has a long life and a high degree of efficiency than the existing electrode UV lamp used in sewage effluent sterilization disinfection. First, we investigated change of UV intensity and temperature of lamp by activation materials. The best results for the dose response experiments were 250 minutes stabilizing to UV intensity of $300{\mu}W/cm^2$ and surface temperature $200{\sim}250^{\circ}C$ in Hg/Ind's weight ratio 95/5. When electrodeless UV lamp emits light for prolonged hours, surface temperature of lamp increases. therefore, temperature change is studied using a duplex lamp for cooling in actual sewerage process. Also, manufactured electrodeless UV lamp showed sterilization efficiency of more than 99.9% as result that experiment manufactured electrodeless UV lamp by E-coli. for sterilization disinfection of sewage effluent.

Reuse of Treated Sewage Water from Absorbent Biofilter System as Agricultural Water Resources (농업수자원으로서의 흡수성 Biofilter 처리수 재이용)

  • 권순국;김현욱;권용웅;조영현;박상원;임경래
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.151-159
    • /
    • 2003
  • Absorbent Biofilter Systems (ABS), composed of an anaerobic septic tank, a pump chamber and an absorbent biofilter tank, have been found to economically provide rural on-site wastewater treatment. This study was conducted to assess the potential of ABS effluent as an alternative water resource for agricultural and environmental use, with respect to the removal of pathogenic microorganism and their fertilization effect. A pilot scale ABS was used to compare its removal efficiency of pathogens from effluent water. Overall, more than 95 percent of Salmonella and E. coli were removed. This result demonstrates that a significant reduction in the pathogenic microorganism of effluents can occur in ABS, which implies the feasibility for the use of ABS effluent in agriculture and environment, with the provision of a further simple disinfection step, in order to satisfy the WHO guidelines for the microbiological quality in agriculture. In addition, because of the abundant nutritional content of ABS effluent, the substitution effect of fertilizer (N, P and K) in paddy irrigation, i.e. 2/3 for nitrogen, l/3 for phosphorus and 1/5 for potassium would be expected. Based on the experimental data, the ABS effluent could be used as a new alternative water resource for paddy irrigation, as well as for environmental purposes, such as supplying water to ecological parks in rural villages.

The Characteristics with HRT Variation on InSub Pilot Plant for Advanced Sewage Treatment

  • Kang, Jin-Young;Huh, Mock
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • The InSub system(applied for a patent) was developed, as it combined the indirectly aerated submerged biofiltration(InSub) reactor and Anaerobic/ Anoxic reactor. This system which can eliminate organism and nutrient materials at the same time, which is safe and economical to be maintained and managed is more simple process than the complicated existing biological advanced sewage treatment system. The most suitable HRT of this study showed 9 hours. As looking into the effluent concentration and removal efficiency of each item at 9 hours of HRT, each effluent concentration for $SS,\;BOD5,\;COD_{Mn},\;and\;COD_{Cr}$ was 1.46 mg/L, 7,09 mg/L, 9.84 mg/L and 16.42 mg/L. And their removal efficiency was 96.98%. 90.59%, 77.18% and 83.92%, respectively. Each effluent concentration of T-N and T-P was 10.42 mg/L and 1.04 mg/L. Their removal efficiency was 73.38% and 61.62%, respectively. This pilot plant experiment(the state was without the internal recycling.) followed a variety of HRT. The results confirmed that it was to be advanced sewage treatment system with high efficiency when it combined with the internal recycling.

Implementation of the Calculation Method for 95% Upper Limit of Effluent Water Quality of Sewage Treatment Plant for Total Maximum Daily Loads : Percentile Ranking Method (수질오염총량관리를 위한 환경기초시설 배출수질의 통계적 평가방법 개선 : 선형보간법의 백분위수방법)

  • Park, Jae Hong;Kim, Dong Woo;Oh, Seung-Young;Rhew, Doug Hee;Jung, Dong Il
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.676-681
    • /
    • 2008
  • The evaluation of the effluent water quality of sewage treatment plant is one of the most important factor in calculating total maximum daily loads (TMDLs). Current method to calculate 95% upper limit of effluent water quality of sewage treatment plant assuming normal distribution of data needs to be implemented in case of non-normal distribution. We have investigated the applicability of percentile ranking method as a non-parametric statistical analysis in case of non-normal distribution of data.

Distribution of Organic Matter and Nitrogenous Oxygen Demand in Effluent of Sewage and Wastewater Treatment Plants (하·폐수처리시설 방류수내 유기물질 및 NOD 분포 특성)

  • Kim, Ho-Sub;Kim, Seok-Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.20-31
    • /
    • 2021
  • In this study, an analysis of the characteristics of organic matter and nitrogenous oxygen demand (NOD) of 17 sewage effluent and wastewater treatments was conducted. High CODMn and carbonaceous biological oxygen demand (CBOD) concentrations were observed in the livestock treatment plants (LTP), wastewater treatment plants(WTP), and night soil treatment plants (NTP), but the highest NOD concentration and contribution rates of NOD to BOD5 were found in sewage treatment plants (STP). There was no significant difference in the CBOD/CODMn ratio for each of the six pollution source groups, but the LTPs, WTPs, and NTPs all showed relatively high CODMn concentrations in their effluent samples, indicating that they are facilities which discharge large amounts of refractory organic matter. The seasonal change of NOD in all facilities' effluent was found to be larger than the seasonal change of CBOD, and data results also revealed an elevation of NOD and NH3-N concentration from December to February, when the water temperature was low. There was no significant difference in NH3-N concentration in relation to pollution source group (p=0.08, one-way ANOVA), but the STP, which had a high NOD contribution rate to BOD5 of 48%, showed a high correlation between BOD5 and NOD (r2=0.95, p<0.0001). These results suggest that the effect of NOD on BOD5 is an important factor to be considered when analyzing STP effluent.

Efficient Sewage Treatment with Less sludge Production by Used Briquets (연탄재를 이용한 슬러지 저감 하수처리 연구)

  • Jeong, Doo-Young;Jeong, Myung-Hee;Song, Dae-Yong;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • We have investigated the efficacy and efficiency of the used briquets for the sewage treatment in this study. The effluent of wastewater treated by Used Briquets Process (UBP) showed very low values of $BOD_5$, CODcr, and SS (1.1 mg/L, 9.5 mg/L, and 3.8mg/L, respectively), which corresponded to 99%, 92.7%, and 96.3% of removal efficiency to the raw wastewater. The number of total bacteria and E. coli in the effluent water treated by UBP was found to be 9 and 1.2 cfu/ml, respectively, showing the remarkable decrease in number, when compared to that of other sewage treatment plants. In the long period of experiment over 1 year, UBP has also shown the high removal efficiency with less sludge production, and low seasonal fluctuation of the values. This UBP is very environmentally-friendly process in the aspects of recycling used briquets and reducing the sludge production. We think that this process will be useful for both the small-scale sewage treatment and reuse of the effluent water.

  • PDF

Study on Microorganism Multiplication Behavior and Efficiency of Chlorine Disinfection in the Sewage Effluent from J Municipal Waste Water Treatment Plant (J 하수 처리장 방류수 중 세균의 성장 거동 및 염소 소독 효율 고찰)

  • Lee, Ungi;Lee, Yoonjin;Jeong, Kyuyean
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.122-128
    • /
    • 2008
  • We evaluated the relationship between the multiplication of heterotrophic microorganisms and physicochemical factors in the final discharged sewage water from J municipal waste water treatment plants. Dissolved organic carbon (DOC) was the most crucial factor influencing multiplication of heterotrophic plate counts (HPC) among the water quality variables selected. Degrading bacteria, such as proteolytic bacteria, lipholytic bacteria, starch degrading bacteria, cellulolytic bacteria, and pectinolytic bacteria, were monitored to understand the condition of nutrients in finished sewage effluent. The percentages of lipid and protein combined occupied 81% in finished sewage water. The multiplication of HPC showed the highest value in August. The formation of trihalomethane (THM) was low in the finished discharge water during chlorine disinfection, which was $71{\mu}/L$ (which was less than $100{\mu}/L$- the standard of drinking water quality) with 10 mg/L of chlorine during 15 min.