• 제목/요약/키워드: Sewage Treatment Efficiency

검색결과 345건 처리시간 0.023초

일체형 입축 프로펠러수차 모형의 수력학적 성능특성 (Hydraulic Performance Characteristics of Vertical-Axis Propeller Turbine Model)

  • 박완순;이철형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.379-382
    • /
    • 2008
  • The propeller type hydro turbine model with vertical axis has been tested and analized. The blade angle of runner of turbine model were designed to be varied according to the condition of head and flowrate. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load such as sewage treatment plants and agricultural reservoirs.

  • PDF

Pilot 규모의 상향류식 충전탑 반응기를 이용한 생활오수의 유기물 및 질소, 인 처리에 관한 연구 (A Study on Removal of Organics, Nitrogen and Phoschorus of Domestic Wastewater in Pilot-Scale Upflow Packed Bed Column Reactor)

  • 선용호
    • KSBB Journal
    • /
    • 제22권4호
    • /
    • pp.191-196
    • /
    • 2007
  • 본 연구는 급속한 산업 발전으로 인해 일어난 많은 수질오염 문제 중 생활하수의 처리방법에 관심을 기울여 생물막 공법을 이용하였는데, 이는 소규모 오폐수 처리장치에서 운전과 유지가 간단하고 활성슬러지 공정보다 넓은 부지를 필요로 하지 않기 때문이다. 생물막 공법 중 생물여상법의 변법을 적용한 Pilot 규모의 상향류식 충전탑형 반응기로 내부의 담체로는 폐토기와 폐비닐을 넣어 혐기조와 호기조를 구성하였고, 생활 오수로는 식당 오수를 이용하여 Lab.-Scale 실험 후 Pilot-Scale로 Scale-up하여 100여일 간에 걸쳐 실험을 수행하였다. 실험은 연속 포기시 일정 HRT에서 유기물과 질소, 인 제거율을 살펴보았다. 실험결과 $BOD_5$와 SS의 평균 제거율은 각각 94.33%와 87.77%로 높은 제거율을 보였으나, $COD_{Cr}$은 81.46%로 목표 제거율 90% 이상에 미치지 못하였고, T-N과 T-P도 각각 71.92%와 21.10%로 예상보다 약간 낮았다. 특히 $COD_{Cr}$와 T-N의 제거율은 지난 Lab.-Scale 때보다 약 10% 정도의 감소를 하여 Pilot-scale에 내외적인 문제가 작용한 것으로 보였다.

하수처리구역내 단독정화조의 성능평가 및 최적 모형의 제안 (Evaluation of the Septic Tank Performance in the Sewage Treatment Area and Suggestion of an Optimum Model)

  • 임봉수;정금희;왕택걸
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.403-409
    • /
    • 2007
  • This study was carried out to recommend the systematic improving practice for the effective operation of septic tank, and the evaluation of its BOD and nutrient removal efficiency depending on process, the survey of characteristics of FRP material, and the suggestion of optimum septic tank model within sewage treatment area. The average BOD concentration and BOD removal efficiency of septic tank which was carried out the cleaning periodically in 63.9 mg/L and 77.8%, shows good quality better than the septic tank which was not carried out the cleaning regularly. Maximum load of tensile, flexural and compressive strength increased in proportion to its thickness, and the contents standard 25% of glass fiber required upgrade over than 30%. Configuration and performance for the optimum of the septic tank suggests that over $0.75m^3$ of the effective total volume, adding to over $0.25m^3$ a man for more than 5 men of the treated person, retention time should be within one day. Improving plans about facility and materials quality of the septic tank have an obligation that protective wall ought to install on the concrete bottom and side faces to prevent crumble or transform from loading of the ground or upper part of the structure on the tank setting. And it is eliminated the uneffective resisting pressure and it keeps off circulate imperfect products by strengthening of the test methods such as stretching strength, pressing strength, glass fiber contents and thickness.

침지형 막결합 연속회분식 반응기를 사용한 하수의 고도처리에서 담체의 효과 (Effect of Media in Advanced Treatment of Sewage Using Submerged Membrane-Coupled Sequencing Batch Reactor)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제26권6호
    • /
    • pp.470-479
    • /
    • 2016
  • 담체가 투여된 침지형 막결합 연속회분식 반응기(SMSBR)를 사용한 하수의 고도처리에서 담체가 여과성능과 제거효율에 미치는 영향을 조사하였다. 담체는 반응기 부피 기준으로 10% 투여하였고, 담체와 분말활성탄을 첨가하지 않은 반응기, 분말활성탄(10 g/L)만을 첨가한 반응기 및 담체와 분말활성탄을 모두 첨가한 반응기를 대조군으로 하였다. COD, T-N 및 T-P에 대한 제거효율은 담체 및 분말활성탄 첨가 유무에 따라 큰 차이가 없었다. 그러나 담체를 첨가하지 않은 경우 막간차압(TMP)은 급격히 증가하였으나, 담체를 첨가한 경우에 막간차압은 매우 서서히 증가하였다. 담체를 투여한 SMSBR를 사용하여 하수를 고도처리 할 때, 91일 이상의 운전기간 동안 막 세정 없이 운전이 가능하였다. 담체만을 투여한 경우, 운전 80일 경과 이후의 COD, T-N 및 T-P 평균 제거율은 각각 95.0, 69.3% 및 51.4%이었다.

폐수처리를 위한 미생물연료전지의 전기생산 특성 (Characteristics of Electricity Generation by Microbial Fuel Cell for Wastewater Treatment)

  • 김선일;이성욱;김경량;이재욱;노성희
    • 공업화학
    • /
    • 제20권2호
    • /
    • pp.213-217
    • /
    • 2009
  • 폐수처리와 동시에 전기를 생산할 수 있는 새로운 대체 에너지 기술로 주목받고 있는 미생물 연료전지(microbial fuel cell, MFC)는 혐기성 조건의 산화전극(anode)에서 미생물에 의한 촉매작용을 통해 유기물질을 분해하면서 화학에너지를 전기에너지로 전환시키는 장치이다. 본 연구에서는 MFC의 성능을 파악하기 위하여 도시하수를 사용하여 폐수처리 효율과 전기생산 특성을 평가하였다. 도시하수에 탄소원으로서 acetate를 주입하였을 때 COD 제거율은 75.7%에서 88.2%로 증가하였으며 전압은 0.22 V에서 0.4 V까지 급격하게 상승하였다. 다양한 외부저항 하에서 전기생산에 미치는 산화전극과 환원전극(cathode) 사이의 전극 거리에 대한 영향 및 산화전극의 표면적에 대한 영향을 조사하였다. 최고 전력밀도는 $610mW/m^2$이었으며, 전극간 거리가 가깝고 산화전극의 표면적이 작을수록 전기발생에 효과적임을 알 수 있었다.

Maximizing biogas production by pretreatment and by optimizing the mixture ratio of co-digestion with organic wastes

  • Lee, Beom;Park, Jun-Gyu;Shin, Won-Beom;Kim, Beom-Soo;Byun, Byoung-su;Jun, Hang-Bae
    • Environmental Engineering Research
    • /
    • 제24권4호
    • /
    • pp.662-669
    • /
    • 2019
  • Anaerobic digestion is a popular sewage sludge (Ss) treatment method as it provides significant pollution control and energy recovery. However, the low C/N ratio and poor biodegradability of Ss necessitate pretreatment methods that improve solubilization under anaerobic conditions in addition to anaerobic co-digestion with other substrates to improve the process efficiency. In this study, three pretreatment methods, namely microwave irradiation, ultrasonication, and heat treatment, were investigated, and the corresponding improvement in methane production was assessed. Additionally, the simplex centroid design method was utilized to determine the optimum mixture ratio of food waste (Fw), livestock manure (Lm), and Ss for maximum methane yield. Microwave irradiation at 700 W for 6 min yielded the highest biodegradability (62.0%), solubilization efficiency (59.7%), and methane production (329 mL/g VS). The optimum mixture ratio following pretreatment was 61.3% pretreated Ss, 28.6% Fw, and 10.1% Lm. The optimum mixture ratio without pretreatment was 33.6% un-pretreated Ss, 46.0% Fw, and 20.4% Lm. These results indicate that the choice of pretreatment method plays an important role in efficient anaerobic digestion and can be applied in operational plants to enhance methane production. Co-digestion of Ss with Fw and Lm was also beneficial.

반탄화목분 천연재료 혼합응집제의 안정성 및 슬러지 에너지화 가능성 평가에 관한 연구 (A Study on the Stability and Sludge Energy Efficiency Evaluation of Torrefied Wood Flour Natural Material Based Coagulant)

  • PARK, Hae Keum;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권3호
    • /
    • pp.271-282
    • /
    • 2020
  • 하수처리장은 도시를 구성하는 사회기반시설물로 2017년 하수도 통계 기준 국내 하수도 보급률은 94%에 달하고 있다. 국내 하수처리장에서 PAC(Poly Aluminum Chloride)의 사용량이 58%를 차지하고 있으나 PAC의 경우 품질기준상 불순물(중금속) 함량이 높음에도 불구하고, 기준 강화나 기술적 품질개선이 제대로 이루어지지 않아 응집제 과다 주입 시 2차 오염문제가 대두되고 있다. 또한, 약품사용량이 증가함에 따라 2017년 기준 연간 하수슬러지 발생량과 슬러지 재이용의 필요성 또한 증대되고 있다. 이에 본 연구에서는 반탄화목분 천연재료 혼합응집제를 이용한 수처리 시 혼합응집제 주입에 따른 중금속류에 대한 안정성을 평가하고, 하수슬러지의 침강성 및 하수슬러지 발열량 평가를 통해 슬러지 재이용의 가능성을 검증하고자 한다. 반탄화목분 천연재료 혼합응집제와 PAC(10%)의 중금속류(Cr, Fe, Zn, Cu, Cd, As, Pb, Ni) 분석 결과 Cr, Cd, Pb, Ni, Hg의 경우 검출되지 않았으며, Zn의 경우 반탄화목분 천연재료 혼합응집제에서 먹는물 수질기준에서 고시한 Zn의 농도가 3mg/L인 것에 비해 0.007 mg/L로 극소량만 검출되었다. Fe, Cu, As의 경우 PAC(10%)를 주입한 경우가 반탄화목분 천연재료 혼합응집제 보다 최대 2배 이상 검출되는 것으로 나타났다. 또한, 슬러지 침강성 분석 결과 반탄화목분 천연재료 혼합응집제가 기존 응집제인 PAC(10%)에 비해 최대 2배 빠르게 침강하는 것으로 반탄화목분 혼합응집제의 침강성이 PAC(10%)보다 우수한 것으로 나타났다. 반탄화목분 천연재료 혼합응집제를 주입하여 발생된 하수슬러지의 건조기준 저위발열량은 3,378 kcal/kg이며, PAC(10%) 응집제를 주입하여 발생된 하수슬러지의 건조기준 저위발열량은 3,171 kcal/kg으로 두 응집제 모두 화력발전소의 보조연료 구비조건을 만족하였으나, 본 연구에서 개발한 반탄화목분 천연재료 혼합응집제를 사용할 경우 기존의 응집제보다 200 kal/kg 정도 높은 슬러지 발열량을 확보할 수 있음을 확인하였다. 따라서, 반탄화목분 혼합응집제를 이용하여 수처리를 수행할 경우 기존의 응집제인 PAC(10%)보다 중금속류에 대해 안정적이며, 우수한 슬러지 침강성과 높은 발열량을 갖는 슬러지를 생성하여 환경적으로 안정적이며, 효율적인 활용이 가능할 것으로 판단된다.

단계유입과 내부순환을 이용한 저농도 하수의 질소처리효율 향상을 위한 연구 (A study on enhancement of nitrogen removal efficiency on low concentration influent sewage)

  • 추태호;김태기;옥치율
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.675-680
    • /
    • 2010
  • 본 연구에서는 저농도로 유입되어 정상적인 운영이 되지 않고, 질소제거가 어려운 소규모 하수처리시설의 문제점을 해결하기 위하여 5Stage로 구성된 하수고도처리 공정의 저농도 유입성상에서 최적의 단계유입비와 내부순환비를 결정하기 위해 Lab-Scale 모형실험장치를 제작하여 실험하였다. 저농도의 유입조건에서 효율적인 고도처리를 위해 내부순환과 단계유입이 공정성능에 미치는 영향을 평가한 결과는 다음과 같다. 첫째, 분석항목별 처리효율은 BOD 90.0%, COD 87.8%, T-N 71.0%, T-P 75.3%로 나타났으며, T-N은 단계유입에 따라 처리효율의 변동이 있는 것으로 나타났다. 둘째, 혐기조로 유입되는 단계유입비 70, 60, 50%에서는 각각 73, 80, 78%로 나타나 최적의 단계 유입비 범위로 판단되었다. 셋째, 질소제거를 위해 내부순환을 할 경우 내부순환을 하지않는 경우보다 질소 제거효율이 증가됨을 알 수 있었고, 내부순환비가 150%이상에서는 더 이상 처리효율에 영향을 미치지 못하는 것으로 나타났다. 이는 다량의 순환으로 인해 무산소조에 DO의 유입으로 인한 것으로 판단된다. 따라서 내부순환비는 50~150%가 적정한 것으로 판단되었다.

하수처리공정에서 이산화탄소를 이용한 스트러바이트 제어에 관한 연구 (A study of struvite control using CO2 in sewage treatment process)

  • 한금석;홍성호;최영준
    • 상하수도학회지
    • /
    • 제32권3호
    • /
    • pp.261-268
    • /
    • 2018
  • Sludge transporting pipes in wastewater treatment plant are easy to be clogged with struvite when the digested sludge and dehydrated filtrate are transported through the pipes, which lowers the efficiency of sludge treatment system in a WWTP. pH is one of the most important factors in struvite formation, and carbon dioxide separated from biogas can be used to control pH and struvite formation. By controlling pH, the amount of dehydrating agent can be reduced by about 10%, which saves the budget for facility maintenance. As $CO_2$ is reused and dehydrating chemicals are saved, the approach can contribute to global warming gas reduction.

동위원소를 이용한 하수 내 지하수 및 우수 함량 산출: 전주 덕진공원 유역 사례 (Calculation of Rainwater and Groundwater Fraction in Sewerage: A Case Study in Deokjin Park, Jeonju)

  • 최승현;김강주;문상호
    • 자원환경지질
    • /
    • 제49권5호
    • /
    • pp.361-370
    • /
    • 2016
  • 하수관거에 지하수가 침투하고 우수가 유입(I/I)되게 되면 하수의 양이 크게 늘어나 하수처리장의 부하가 가중되고, 하수의 처리효율도 크게 감소되기 때문에, 하수 중의 I/I를 알아내는 것은 매우 중요하다. 본 연구는 산소 및 수소 동위원소를 이용한 I/I 측정가능성 검토를 목적으로 수행되었으며, 이를 위하여 전주시 덕진공원 유역 내 관정 지하수 및 수로수, 상수도 등에 대하여 동위윈소적 조사를 수행하였다. 본 연구를 통하여 전주지역의 상수도는 전주에서 내륙으로 약 40 km 떨어진 고지대에 위치한 용담댐을 수원으로 하기 때문에 지역 강우와는 뚜렷이 다른 동위원소적 특성을 보이고, 시간에 따른 조성의 변화도 거의 없음을 알게 되었다. 하수는 기본적으로 상수도에서 발생하므로, 상수도와 지역강우를 양극단으로 하여 하수로 내 지역강우의 함량을 계산할 수 있다. 이러한 방법으로 덕진공원 유역 내하수로 1개 지점에서 지역강우의 함량을 계산한 결과, 강우가 시기에 따라 하수의 50%에서 90%를 차지하는 것으로 확인되었다. 이러한 계산결과는 오염농도가 높지 않은 하수의 수질을 통하여도 잘 뒷받침된다. 같은 방법으로 계산된 지하수내 상수도의 함량도 약 46%나 되었으며, 이는 상수도의 누수가 중요한 지하수원이 되고 있음을 지시하는 것이다. 이러한 동위원소 조성을 갖는 지하수는 하수로에 유입되어도 하수의 동위원소에는 크게 영향을 주지 않기 때문에 실제로 하수로에 유입되는 우수와 지하수의 량은 계산 결과보다 훨씬 클 것으로 예상된다.