• Title/Summary/Keyword: Setup variation

Search Result 104, Processing Time 0.026 seconds

Measurement of noise characteristics of an image sensor (화상센서의 잡음 특성 측정)

  • Lee, Tae-Kyoung;Hahn, Jae-Won
    • Transactions of the Society of Information Storage Systems
    • /
    • v.5 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • We setup the system to measure the noise characteristics of the 5M complementary metal-oxide semiconductor (CMOS) image sensor by generic measurement indicator of Standard mobile imaging architecture (SMIA) which is one of internal standard of mobile imaging architecture. To evaluate the effect of environment and setting parameters, such as temperature and integration time, we measure the variation of the dark signal, dynamic range and fixed pattern noise of image sensor. We also detect the number of defective pixels and cluster defects defined as adjacent single defect pixels at 5M CMOS image sensor. Then, we find the existence of some cluster defects in experiment, which are not expected in calculation.

  • PDF

Technology of Dimensional Control for Different Thickness Strip in Hot Strip Finishing Mills (열간 마무리압연에서 이종두께 강판의 치수제어기술)

  • Lee, Sang Ho;Park, Hong Bae;Park, Cheol Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.8
    • /
    • pp.735-741
    • /
    • 2015
  • In this paper, we suggest a dimensional controller to produce a different thickness strip without adding production facilities at the same steel. We describe the model for the non-linear thickness and speed setup, and drive a variation of the speed and thickness with Talyor expansion. The control algorithm is composed of 8 steps and the transient condition is added in order to maintain a mass flow between stands. A simulator is developed in order to verify the algorithm, and includes a non-linear rolling model, the tension model, AGC model, the disturbance model, and so on. From the simulation results by disturbances, we show that the thickness, tension and looper angle are converged to the set condition when we change the rolling conditions.

Performance evaluations of a link state update mechanism considering traffic variation (트래픽 변화를 고려한 링크 상태 업데이트 알고리즘의 성능 분석)

  • Choi Seung-hyuk;Jung Myoung Hee;Chung Min Young;Yang Mijeong;Kim Tae Il;Park Jaehyung
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2005.11a
    • /
    • pp.13-18
    • /
    • 2005
  • Routers determine routing path considering network topology and link state information for providing QoS (quality of service) guarantee. Therefore, it is important that routers know link state information to calculate routing path. However, if routers generate link state update messages inordinately, their router performance are reduced due to the process of link state update messages. On the other side, in case that link state information is not updated appropriately, route setup requests can be rejected even though there exist routes. In this paper, we propose an algorithm to improve router performance and evaluate the proposed algorithm performance compare with conventional algorithm by simulations.

  • PDF

An Experimental Study on the Energy Separation in a Low Pressure Vortex Tube for Engine (기관적용 저압용 vortex tube의 에너지 분리특성에 관한 실험적 연구)

  • 오동진;임석연;윤면근;류정인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.235-241
    • /
    • 2002
  • The process of energy separation in a low pressure vortex tube with air as a working medium is studied In detail. Experimental data of the temperature of the cold and hot air leaving the vortex tube are presented. The variation of the maximum wall temperature along the inner surface of the vortex tube and the temperature distribution in the vortex tube provides useful information about the location of the stagnation point of the flow field at the axis of the vortex tube. In this study Outer tube is used for the application of Diesel engine exhaust. The hot gas flow is fumed 180° and passes the outside of the vortex tube a second time heating it. From this geometric setup of a vortex tube the effects of energy separation and the prediction of the ignition of Diesel Soot is presented by experimental data.

A Parallel Operation of DC/DC Converter for suitable Photovoltaics System (태양광 발전에 적합한 DC/DC 컨버터의 병렬운전)

  • Kim Byeong-Woo;Park Sung-Jun;Moon Chae-Ju;Nam Hae-Kon;Kim Cheul-U;Kim Jong-Dal
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1498-1500
    • /
    • 2004
  • A novel technique for efficiently extracting maximum power from PV panels is proposed, consisting of a modified buck-boost converter, witch is controlled by a DSP. A variation of the proposed MPPT technique is directly use the modified buck-boost converter current reference as a control parameter. Also 4 parallel boost converters have division of load. A theoretical analysis of the proposed converter is performed and compared with experimental results obtained from a 1k[W] prototype solar panel under a controlled experimental setup.

  • PDF

Scanning confocal microscope of a surface following effect using a quad-detector (4분할 광검출기를 이용한 표면 추적 효과의 공초점 현미경)

  • 김수철;송장섭;권남익
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.1
    • /
    • pp.1-4
    • /
    • 1998
  • A compact scanning confocal microscope has been constructed using a quad-detector in a CD-player. The variation of error signal on depth which obtained by a quad-detector is used in the scanning confocal microscope. Bipolar error signals, which is sensitive near a focus, give a surface following effect whiout following the surface. In the case of small depth difference, the difference of materials through the reflection signal has been identified. The image which uses reflection signal only, has been obtained with the same setup. And, the results obtained in two different way were compared and analyzed.

  • PDF

Experimental study on the effects of stern bulb arrangement on the slamming load

  • Park, Jongyeol;Choi, Ju Hyuck;Lee, Hyun-ho;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.518-530
    • /
    • 2020
  • The present study concerns the stern slamming load of container carriers, with stern bulb arrangement variation. First, a series of wedge drop tests were conducted using simple wedge models with fixed deadrise angles, and tests with the cross-section models of practical container carrier sterns were followed. The deadrise angle of the simple wedge ranged from 0° to 10°. The pressure measurement results of the simple wedge drop tests were distributed between empirical formula and analytic solution, so the experimental setup was validated. In the cases of practical hull cross-sections, the water entry of the bulb prior to that of the transom resulted in characteristic water film generation and delayed pressure peak appearance. The trapped air between the bulbs damped the pressure in the twin skeg hull case, reducing the pressure peak and causing the pressure oscillation during water entry.

An Experimental Study on the Energy Separation in the Geometric Setup of a Low Pressure Vortex Tube (저압용 vertex tube의 기하학적형상에 따른 에너지 분리특성에 관한 실험적 연구)

  • 오동진;류정인
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.276-282
    • /
    • 2002
  • The process of energy separation in a low Pressure vortex tube with compressed air as a work-ing medium is studied in detail. Experimental data of the temperature of the cold and hot air leaving the vortex tube are presented. The variation of the maximum wall temperature along the inner surface of the vortex tube and the temperature distribution in a vortex tube provide useful information about the location of the stagnation point of the flow field at the axis of the vortex tube. Analysis of the results enabled to find the optimum length of the vortex tube, the optimum shape of the Throttle and the usefulness of the Sleeve. In this study Outer tube is used for the exhaust application. The hot gas flow is turned 180$^{\circ}$and passes the out-side of the vortex tube a second time heating it. From this geometric setup of a vortex tube He effects of energy separation and the prediction of the ignition of Diesel Soot is presented by experimental data.

Design and Analysis of Magneto-Rheological Damper Using Permanent Magnet (영구자석을 이용한 전단모드 MR 댐퍼 설계 및 해석)

  • Kim, Wan Ho;Suresh, Kaluvan;Park, Jhin Ha;Choi, Sang Min;Park, Chun-Yong;Kang, Je-Won;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.443-448
    • /
    • 2016
  • A novel Permanent Magnet based Magneto Rheological (PM-MR) damper is proposed in this paper. The principle of proposed MR damper is achieved by designing a linearly varying magnetization area with-respect to the movable permanent magnetic based piston setup. Nowadays, commercially available MR damper uses electromagnetic coils for generating the variable magnetic fields corresponding to the variable damping force. The amount of magnetic field produced by the electromagnetic coils are depends on the biasing current of voltage source. The key enabling concept of the proposed MR damper is to replace the electromagnetic coils and the voltage sources by utilizing the variable area based permanent magnetic piston setup. The proposed unique design structure of PM-MR damper has an increasing shear mode damping force with the piston movement in both jounce and rebound motion. In this research, analytical model of the proposed structure is derived and the structural design of proposed concept is verified using numerical CAD tool. As a result, the damping force is increase when piston movement in both jounce and rebound motion.

Evaluation of dose delivery accuracy due to variation in pitch and roll (세기변조방사선치료에서 Pitch와 Roll 변화에 따른 선량전달 정확성 평가)

  • Jeong, Chang Young;Bae, Sun Myung;Lee, Dong Hyung;Min, Soon Ki;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.239-245
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the pitch and roll rotational setup error with 6D robotic couch in Intensity Modulated Radiation Therapy (IMRT) for pelvic region in patients. Materials and Methods : Trilogy(Varian, USA) and 6D robotic couch(ProturaTM 1.4, CIVCO, USA) were used to measure and analyze the rotational setup error of 14 patients (157 setup cases) for pelvic region. The total 157 Images(CBCT 78, Radiography 79) were used to calculate the mean value and the incidence of pitch and roll rotational setup error with Microsoft Office Excel 2007. The measured data (3 mm, 3%) at the reference angle ($0^{\circ}$) without couch rotation of pitch and roll direction was compared to the others at different pitch and roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) to verify the accuracy of dose delivery by using 2D array ionization chamber (I'mRT Matrixx, IBA Dosimetry, Germany) and MultiCube Phantom(IBA Dosimetry, Germany). Result from the data, gamma index was evaluated. Results : The mean values of pitch and roll rotational setup error were $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$. The maximum values of them were $2.8^{\circ}$, $2.0^{\circ}$. All of the minimum values were zero. The mean values of gamma pass rate at four different pitch angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 97.75%, 96.65%, 94.38% and 90.91%. The mean values of gamma pass rate at four different roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 93.68%, 93.05%, 87.77% and 84.96%. when the same angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$) of pitch and roll were applied simultaneously, The mean values of each angle were 94.90%, 92.37% and 87.88%, respectively. Conclusion : As a result of this study, it was able to recognize that the accuracy of dose delivered is lowered gradually as pitch and roll increases. In order to increase the accuracy of delivered dose, therefore, it is recommended to perform IGRT or correct patient's position in the pitch and roll direction, to improve the quality of treatment.