• 제목/요약/키워드: Setup errors

검색결과 126건 처리시간 0.041초

Analysis on Setup Variation According to Megavoltage Computed Tomography System

  • Kim, Sun-Yung;Kim, Hwa-Sun;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.425-430
    • /
    • 2016
  • The aim of this study was to measure the setup variation for X (lateral), Y (longitude), and Z (vertical) by taking magnetic megavoltage computed tomography (MVCT) before treating the brain, oropharynx, lung, and prostate patients on helical tomotherapy. In this study, 30 patients were chosen for each of the treatment areas, and their skin was labeled with a mark on a treatment planning reference point when taking CT. We preceded MVCT prior to tomotherapy and then conducted an auto registration based on the bony landmarks; image registration was used for automatically matching the patient's setup. Lastly, we confirmed and evaluated the translation coordinates of the images for 30 patients. The following shows the comparison result of the setup errors of each part: X (lateral) showed the highest setup errors with $3.44{\pm}2.05$ from Lung; Y (longitude) showed the highest setup errors showing $3.40{\pm}2.87mm$ from Prostate; and Z (vertical) showed the highest setup errors showing $6.62{\pm}4.38mm$ from Lung. This result verifies that the setup error can be prevented by taking MVCT before the treatment, and Planning Target Volume (PTV) margins can be reduced by referring to the resulting value of each treatment part. Ultimately, the dosage of the normal organs can be decreased as well as any side effects.

토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가 (Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System)

  • 정재홍;조광환;이정우;김민주;임광채;문성권;김용호;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제22권2호
    • /
    • pp.72-78
    • /
    • 2011
  • 본 연구의 목적은 토모테라피(Hi-ArtII, TomoTherapy, USA) 치료 시 Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany)에서 진공압박(Vacuum compression)에 따라 환자 위치잡이오차(Patient's setup-errors)를 평가하고자 하였다. Bodyfix system와 진공압박을 적용한 토모테라피를 이용하여 치료를 시행한 흉복부 환자 21명을 선정하였으며, 모든 환자는 치료 전 촬영된 총 477개의 메가볼테이지 전산화단층촬영(Mega-voltage computed tomography, MVCT)영상을 얻었다. 이를 통하여 확인된 좌우방향(Medial-Lateral direction, ML), 앞뒤방향(Anterior-Posterior direction, AP), 상하방향(Superior-Inferior direction, SI)과 SI중심축 회전각(Rotational angle of SI axis direction, Roll)에 대한 오차를 기록하고, 분석하였다. 세 방향 및 Roll에 대한 상관관계와 진공압박 정도가 다르게 적용된 다섯 그룹에 대하여 setup-errors를 분석하기 위해 각각 Pearson's product-moment coefficient와 One-way ANOVA를 이용하여 통계적으로 분석하였다(p<0.05). 분석결과 Systematic errors의 평균은 AP에서 6.00 mm, 표준편차는 SI에서 5.95 mm로 큰 오차를 보였다. Random errors의 평균은 SI방향에서 4.72 mm로 큰 오차가 발생하였다. 관계분석에서는 상관계수가 ML-Roll과 AP-Vector는 0.485, 0.244이고, SI-Vector에서 관계가 제일 높았다(0.637). 또한, 진공압박 정도가 다르게 적용된 다섯 그룹(Pressure range: 30~70 mbar) 사이의 setup errors를 분석한 결과 ML, SI방향과 Roll에서 모두 p=0.00 (p<0.05)로써 유의한 차이를 보였으며, SI방향에서 진공압박에 따른 오차 평균은 40 mbar과 70 mbar그룹에서 4.78 mm, -0.74 mm였다. 본 연구에서는 진공압박과 setup-errors의 평가를 통계적으로 분석하였으며, 압박 정도에 따라 SI방향에서 setup-errors의 차이를 확인하였다. 최종적으로 setup-errors와 내부장기의 움직임을 고려하자면 Bodyfix system을 이용한 진공압박을 적용시 최소 50 mbar 이상을 사용해야 할 것이다. 본 연구결과를 토대로 진공압박의 정확성과 내부장기 및 종양의 움직임을 정량적으로 분석할 필요가 있다고 판단된다.

V-그루브 미세가공에서의 공구 및 공작물 셋업 해석 (Analysis of Tool and Workpiece Setup in v-Groove Micromachining)

  • 조정우;양민양
    • 대한기계학회논문집A
    • /
    • 제30권8호
    • /
    • pp.957-964
    • /
    • 2006
  • As the requirement of LCD products which are large screen and have high brightness increases, the role of light guide panel (LGP) of which micro-features diffuse the light uniformly on surface is getting important. In general, there are many errors in machining like machine tool errors process error, setup error and etc. The amount of setup error in general machining is not so big in comparison with the others, so it is mostly neglected. But, especially in v-groove micromachining, setup error has a significant effect on micro-features. Low quality product and high cost are resulted from setup error. In v-groove micromachining, to confirm the effect of setup error, it is identified and then setup error synthesis model is derived from analysis of tool and workpiece setup. In addition, to predict the micro-features affected by setup error and enhance the production efficiency, the setup condition satisfying the tolerance of micro-features is geometrically analyzed and presented.

QUANTITATIVE DATA TO SHOW EFFECTS OF GEOMETRIC ERRORS AND DOSE GRADIENTS ON DOSE DIFFERENCE FOR IMRT DOSE QUALITY ASSURANCE MEASUREMENTS

  • Park, So-Yeon;Park, Jong-Min;Ye, Sung-Joon
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.183-189
    • /
    • 2011
  • To quantitatively evaluate how setup errors in conjunction with dose gradients contribute to the error in IMRT dose quality assurance (DQA) measurements. The control group consisted of 5 DQA plans of which all individual field dose differences were less than ${\pm}5%$. On the contrary, the examination group was composed of 16 DQA plans where any individual field dose difference was larger than ${\pm}10%$ even though their total dose differences were less than ${\pm}5%$. The difference in 3D dose gradients between the two groups was estimated in a cube of $6{\times}6{\times}6\;mm^3$ centered at the verification point. Under the assumption that setup errors existed during the DQA measurements of the examination group, a three dimensional offset point inside the cube was sought out, where the individual field dose difference was minimized. The average dose gradients of the control group along the x, y, and z axes were 0.21, 0.20, and 0.15 $cGy{\cdot}mm^{-1}$, respectively, while those of the examination group were 0.64, 0.48, and 0.28 $cGy{\cdot}mm^{-1}$, respectively. All 16 plans of the examination group had their own 3D offset points in the cube. The individual field dose differences recalculated at the offset points were mostly diminished and thus the average values of total and individual field dose differences were reduced from 3.1% to 2.2% and 15.4% to 2.2%, respectively. The offset distribution turned out to be random in the 3D coordinate. This study provided the quantitative data that support the large individual field dose difference mainly stems from possible geometric errors (e.g., random setup errors) under the influence of steep dose gradients of IMRT field.

아마추어골퍼들의 스윙 오류에 관한 연구 (A Study of Golf Swing Errors of Amateur Golfer)

  • 임정;전철우;정재욱
    • 한국운동역학회지
    • /
    • 제16권2호
    • /
    • pp.165-174
    • /
    • 2006
  • The purpose of this study was to review the relevant literature about coaching and thereupon, survey the coaching methods used for golfer lesson to reinterpret them and thereby, describe in view of kinetics the swing errors committed frequently by amateur golfers and suggest more scientific golfer coaching methods. For this purpose, kinetic elements were divided into precision and power ones and therewith, the variables affecting such elements were identified. On the other hand, swings were divided into address, take-back, back-swing, back-swing top, down-swing, impact and follow-through to determine 20 variables for each form and thereby, define their errors to determine the relations between their frequency and errors. For this study, a total of 60 amateur golfer were sampled, and their swing forms were photographed with two high-speed digital cameras, and the resultant images were analyzed to determine the errors of each form kinetically, which would be analyzed again with the program V1-5000. The results of this study can be summarized as follows; The kinetic elements could be identified as precision, power and precise power. Thus, setup and trajectory were classified into precision elements, while differences of inter-joint angles, cocking and delayed hitting. Lastly, timing and axial movement were classified into precise power elements. Three errors were identified in association with setup. The errors related with trajectory elements accounted for most (7) of the 20 errors. Three errors were determined for inter-joint angle differences, and one error was associated with cocking and delayed hitting. Lastly, one error was classified into timing error, while five errors were associated with axial movement. Finally, as a result of arranging the errors into a cross table, it was found that the errors were associated with each other between take-back and back-swing, take-back and follow-through, back-swing and back-swing top, and between back-swing and down-swing. Namely, an error would lead to other error repeatedly. So, it is more effective to identify all the errors for every form and correct them comprehensively rather than single out the errors and correct them one by one.

호흡 동조 췌장 암 용적 세기조절 회전 치료 시 Inter-fraction Intra-fraction 분석 (Analysis of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in Pancreas Ca)

  • 조영필;서동린;홍택균;강태영;백금문;홍동기;윤인하;김진산
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.247-256
    • /
    • 2014
  • 목 적 : 췌장 환자 방사선 치료 중 기점(Fiducial) 대상 내부 및 외부 종양 움직임의 오차를 정량화 하고자 한다. 또한 cone beam computed tomography (CBCT) 를 기반으로 호흡 시 췌장의 움직임 분석하고자 한다. 대상 및 방법 : 용적 세기변조 회전조사 (V-MAT)를 적용, 정위적 방사선 치료를 국소 진행성 췌장암 환자 11명을 대상으로 하였다. CBCT 및 직교 투시이미지를 적용하여 기점(Fiducial Marker)의 Inter, intra-fraction 움직임 변화를 치료 전, 치료 진행 시 분석하였다. 결 과 : 치료 후 프로토콜을 오프라인 교정 프로토콜을 사용하여, CBCT 와 직교투시 간의 평균 오차(범위)는 0.0(-1.7~4.0), 0.3(-0.5~3.0) and 0.0(-4.1~6.6)mm 측방 (LR), 세로 (AP) 및 종 방향 (SI) 이였다. 무작위 Inter-fraction Setup 오차 결과는 -0.1, -2.3 and -1.1 mm: 95% Fiducial포함 마진은 각 9.9, 7.8, 12.5mm로 수식되었다. 결 론 : 위 분석으로 뼈 일치 정렬 후 잔류 불확실성이 있으며, SI 방향에 큰 임의의 움직임은 적합한 여백이 필요하다. 주변 내부 장기를 보호, 내부 장기 문제점을 최소화, 호흡편차를 고려, 치료 시 정기적으로 측정하여야 한다.

골프스윙오류의 운동역학적 분류 (Kinetic Classification of Golf Swing Error)

  • 전철우;황인승;임정
    • 한국운동역학회지
    • /
    • 제16권4호
    • /
    • pp.95-103
    • /
    • 2006
  • The purpose of this study was to review the relevant literature about coaching and thereupon, survey the coaching methods used for golf lesson to reinterpret them and thereby, describe in view of kinetics the swing errors committed frequently by amateur golfers and suggest more scientific golf coaching methods. For this purpose, kinetic elements were divided into accuracy and power ones and therewith, the variables affecting such elements were identified. For this study, a total of 60 amateur golfer were sampled, and their swing forms were photographed with two high-speed digital cameras, and the resultant images were analyzed to determine the errors of each form kinetically, which would be analyzed again with the program V1-5000. The kinetic elements could be identified as accuracy, power and accuracy & power. Thus, setup and trajectory were classified into accuracy elements, while differences of inter-joint angles, cocking and delayed hitting. Lastly, timing and axial movement were classified into accuracy & power elements. Three errors were identified in association with setup. The errors related with trajectory elements accounted for most (6) of the 20 errors. Three errors were determined for inter-joint angle differences, and one error was associated with cocking and delayed hitting. Lastly, one error was classified into timing error, while five errors were associated with axial movement. Finally, as a result of arranging the errors into a cross table, it was found that the errors were associated with each other between take-back and back-swing, take-back and follow-through, back-swing and back-swing top, and between back-swing and down-swing. Namely, an error would lead to other error repeatedly. So, it is more effective to identify all the errors for every form and correct them comprehensively rather than single out the errors and correct them one by one.

원격방사선치료 기록부의 QA 에서 물리적 측면의 고찰 (A Cosideration on Physical Aspects in Teleradiotherapy Chart QA)

  • 강위생;허순녕
    • 한국의학물리학회지:의학물리
    • /
    • 제10권2호
    • /
    • pp.95-101
    • /
    • 1999
  • 원격방사선치료 기록부의 QA 과정에서 관찰된 환자에 대한 부정확한 자료나 방사선치료 기록부에 기록이나 이기의 오류로 인한 선량이나 선량분포의 오류의 종류와 빈도를 분석하는 것이다. 서울대학교병원 치료방사선과에서는 수치 오류을 시정하기 위해 의학물리학자가 치료개시전과 일주일에 일회 이상 방사선치료 기록부의 병록지와 배치도면, MU 계산용지나 치료계획 요약지, 일일 치료기록지를 점검하고 있다. 관찰된 오류를 다음과 같이 분류하였다. 1) 환자신원 확인, 2) 물리적인 요소를 포함하지 않지만 병록지의 누락이나 미기재, 3) 배치도면의 누락이나 setup 에 필요한 자료의 누락과 착오, 4) MU와 점선량 계산용지에서는 MU의 오류의 중요 원인별로 구분 및 점선량의 오류, 5) 치료계획 요약지의 분실여부와 환자자료의 오류, 6) 일일 치료기록지에서는 치료사실의 기재누락, 치료일정 착오, 처방선량 착오, setup 착오, MU 착오, 누적선량착오, 7) 선량이나 선량분포의 부정확성을 초래한 오류와 그런 가능성은 있지만 실제 실현되지 않은 오류, 단순히 기록상의 오류 , 8) 서명의 누락에 대해 검사하였으며, 결과는 환자의 수 대신 오류 건수별로 분석하였다. 1996년 6월 17일부터 1999년 7 월 31 일까지 방사선치료 기록부의 QA 에서 환자신원의 불일치는 한건도 없었으며 ,399명의 환자에 대해 431건의 오류가 관찰되었다. 물리적인 오류는 405건, 병록지의 누락 또는 미기재가 9 건, 서명누락이 17건이었다. 배치도면이 없는 경우 23 건 (5.7%), 자료의 누락 21건 (5.2%), 자료의 오기 73건(18.0%) 이었으며, MU의 계산용지가 없거나 계산 없이 치료가 시행된 경우는 13건 (3.2%), MU 계산의 착오 68 건 (16.3%), 점선량의 계산착오 8 건(2.0%), 방사선치료계획 결과 용지의 분실이 1건 (0.2%), 환자자료의 입력 오류가 11건(2.7%), 치료기록의 누락이나 치료의 누락이 8건(2.0%), 치료일정의 오류 13건 (3.2%), MU 계산이나 치료계획의 처방선량과 일일 치료기록지 처방선량의 불일치 20건(4.9%), 치료 setup 의 착오 33건(8.1%), MU의 설정 착오 52건(12.8%), 누적선량 착오 61건(15.1%) 이었다. 선량이나 선량분포의 부정확성을 초래한 오류는 239건(59.0%) 이었으며, 그런 가능성은 있지만 실제 실현되지 않은 오류 142건(35.1%), 단순히 기록상 오류는 24건 (5.9%) 이었다. 관찰된 수치 오류는 다양한 분야에 걸쳐 있었다. 나타난 대부분의 오류는 선량이나 선량분포의 오류에 직접 기여하거나 기여할 우려가 있기 때문에 방사선치료 기록부에서 물리적인 면의 QA를 철저하게 할 필요가 있다.

  • PDF

성문암 세기변조방사선치료에서 두 가지 열가소성 마스크에 대한 환자위치잡이 오차 평가 (Comparison of Setup Deviations for Two Thermoplastic Immobilization Masks in Glottis Cancer)

  • 정재홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.63-70
    • /
    • 2017
  • 본 연구는 세기변조방사선 치료기술을 이용한 성문암 환자에게 사용되는 두 가지 상이한 열가소성 고정기구 마스크로 인한 환자위치잡이 오차를 비교 평가하고 자 하였다. 치료가 종료된 총 16명의 성문암 환자를 두 그룹으로 나누었고(기존마스크 vs. 변형마스크), 평균, 3D오차, 시스템과 랜덤오차를 구하여 환자위치잡이 오차를 비교하였다. 또한, 치료계획종양체적(PTV)에 대한 여백(margin)을 분석하였다. 3D오차에 대하여 기존 그룹은 $5.2{\pm}1.3mm$고, 변형그룹은 $5.9{\pm}0.7mm$로써, 변형마스크가 변형보다 13.6% 높았다. 시스템오차는 기존그룹(변형그룹)에서 좌표 x, y, z방향은 각각 1.7 mm (1.1 mm), 1.0 mm (1.8 mm), 1.5 mm (2.0 mm)였고, 회전각(roll angle)은 $0.8^{\circ}$ ($0.8^{\circ}$)였다. 랜덤오차는 변형그룹이 기존그룹에 비하여 좌표 x, y, z방향으로 10.9%, 1.7%, 23.1%로 낮았으나, 회전각은 12.4% 높았다. PTV여백에서 변형그룹은 좌표 x방향에 대하여 기존그룹에 비하여 31.8% 낮았으나, 반대로 좌표 y와 z방향에서는 기존그룹보다 각각 52.6%와 21.6%로 높았다. 성문암 세기변조방사선치료에서 변형된 마스크 사용은 고정기구의 변형으로 인한 환자위치잡이 오차는 수치적으로는 영향을 줄 수 있지만, 다양한 관점에서 고정기구 마스크에 대한 연구가 임상적인 측면에서 연구가 필요할 것으로 사료된다.

On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구 (Analyses of the Setup Errors using on Board Imager (OBI))

  • 김종덕;이행오;유재만;지동화;송주영
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.1-5
    • /
    • 2007
  • 목적: 방사선치료 시 OBI (on board imager) 시스템으로 환자 셋업 오차(set-up error)를 확인, 보정한 결과를 분석하여, 셋업 오차(set-up error)의 경향 및 원인을 살펴보고, 기존 필름과 EPID (electronic portal imaging device)를 사용한 방법에 비해 OBI의 정확성과 유용성에 대하여 알아보고자 한다. 대상 및 방법: 2006년 3월부터 2006년 5월까지 본원에 내원한 3차원 치료계획 환자 130명을 대상으로 주 1회 이상 OBI를 이용하여 치료전 셋업 영상의 분석을 시행하였다. 직각으로 획득한 2개의 영상을 모의 치료실에서 획득한 기준영상(reference image)과 합성(Fusion) 후 분석을 하였다. 분석 후 Vertical, Lateral, Longitudinal 방향으로 변위(Shift)거리를 측정하여 오차를 분석했다. 또한, 주요 부위별, 방향별로 구분하여 셋업 오차(set-up error) 요인들을 비교, 평가하였다. 결과: OBI를 적용하여 분석한 환자 41.5%에서 변위가 없이 Setup이 정확하였고, 52.3%에서 $1{\sim}5mm$정도의 오차가 존재하였다. 5 mm오차 이상인 환자도 6.1%가 확인되었다. 5 mm이상의 오차를 보인 환자들은 치료실내에서 확인한 결과 환자의 움직임이나 모의치료 자세와의 차이에서 오는 결과임을 알 수 있었다. 또한, 3 mm이상의 오차 경향이 3번 이상 지속될 경우에는 모의 치료실로 이동하여 보정후 치료를 시행하였다. 결론: 치료 전 2인의 근무자가 셋업을 정확히 하고 3면의 레이저와 조사야를 확인하였지만, 직각의 KV 영상으로 분석한 결과 셋업 오차가 발생할 수 있음을 확인하였다. 기존의 EPID에 의한 MV 영상은 낮은 영상의 특성과 환자의 피폭선량 증가라는 단점이 존재하지만, 본 연구에서 분석한 OBI는 모의 치료와 같은 높은 화질의 영상으로 셋업 오차의 정확한 계산과 객관적인 셋업 보정이 가능하여 영상유도 방사선치료의 정확도와 유용성을 입증할 수 있었다.

  • PDF