• Title/Summary/Keyword: Setup Planning

Search Result 144, Processing Time 0.03 seconds

Special Purpose Company and Drama Production: A Case Study of KGCS (방송드라마 제작방식으로서 문화산업전문회사에 대한 연구: KGCS문화산업전문회사를 중심으로)

  • Yu, Konshik;Moon, Sanghyun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.172-180
    • /
    • 2014
  • The purpose of this study is to examine how the Munjeonsa(SPC) has influenced the way terrestrial broadcasting networks produce drama. The study has three research objectives. First, this study investigates why the networks use SPC for drama production. Second, the study examines the features in the process of the setup and operation of SPC. Third, the study identifies the impacts of SPC on networks' drama production. This study analyzes which was produced by KBS SPC. The results of this study are as follows. First, networks introduce SPC to procure an enormous production costs and to manage the production system transparently and efficiently. Second, the feature of networks' SPC(KGCS SPC) is that it has a unique dual structure with main and project SPC. Third, SPC influences drama production system in various ways; revitalization of external investment, accounting transparency, growing of network's planning dramas, securing intellectual properties and revenue diversification.

Analysis of Flood due to Storm Surge at Masan Bay (마산만에서 고조로 인한 침수원인 분석)

  • 황호동;이중우;권소현
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.217-224
    • /
    • 2004
  • Open-coast storm surge computations are of value in planning and constructing engineering works, especially in coastal regions. Prediction of typhoon surge elevations is based primarily on the use of a numerical model in this study, since it is difficult to study these events in real time or with use of physical models. A simple quasi-two dimensional numerical model for storm surge is considered. In order to understand the model's underlying assumptions, range of validity, and application, we discussed several aspects of typhoons and the physical factors governing storm generation processes. We also followed the basic governing equation, together with the assumption generally taken in their development, to see the principle characteristics of the model from a physical as well as a mathematical point of view. The equations consistent with the model described here are reduced forms of the basic equations and their effects on the resulting numerical scheme are discussed. Finally we applied the model discussed above to a storm surge problem at Masan Bay, the south coast of Korea Effects of astronomical tide, initial water level, and atmospheric pressure setup are considered. We then analyzed the flood at the coastal city and proposed a reasonable way of flood control.

  • PDF

Auto-segmentation of head and neck organs at risk in radiotherapy and its dependence on anatomic similarity

  • Ayyalusamy, Anantharaman;Vellaiyan, Subramani;Subramanian, Shanmuga;Ilamurugu, Arivarasan;Satpathy, Shyama;Nauman, Mohammed;Katta, Gowtham;Madineni, Aneesha
    • Radiation Oncology Journal
    • /
    • v.37 no.2
    • /
    • pp.134-142
    • /
    • 2019
  • Purpose: The aim is to study the dependence of deformable based auto-segmentation of head and neck organs-at-risks (OAR) on anatomy matching for a single atlas based system and generate an acceptable set of contours. Methods: A sample of ten patients in neutral neck position and three atlas sets consisting of ten patients each in different head and neck positions were utilized to generate three scenarios representing poor, average and perfect anatomy matching respectively and auto-segmentation was carried out for each scenario. Brainstem, larynx, mandible, cervical oesophagus, oral cavity, pharyngeal muscles, parotids, spinal cord, and trachea were the structures selected for the study. Automatic and oncologist reference contours were compared using the dice similarity index (DSI), Hausdroff distance and variation in the centre of mass (COM). Results: The mean DSI scores for brainstem was good irrespective of the anatomy matching scenarios. The scores for mandible, oral cavity, larynx, parotids, spinal cord, and trachea were unacceptable with poor matching but improved with enhanced bony matching whereas cervical oesophagus and pharyngeal muscles had less than acceptable scores for even perfect matching scenario. HD value and variation in COM decreased with better matching for all the structures. Conclusion: Improved anatomy matching resulted in better segmentation. At least a similar setup can help generate an acceptable set of automatic contours in systems employing single atlas method. Automatic contours from average matching scenario were acceptable for most structures. Importance should be given to head and neck position during atlas generation for a single atlas based system.

Investigation of Subsurface Deformations for the Shallow Tunnel In A Granular Mass Using Two-Dimensional Laboratory Model Test and Numerical Analysis (2차원 실내모형실험과 수치해석을 이용한 사질토 지반의 얕은 터널에 대한 지중변형에 대한 규명)

  • Lee, Yong-Joo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.219-228
    • /
    • 2006
  • In urban areas, tunnelling induced ground deformations, particularly ground settlements should be considered in order to minimize the damage of adjacent structures. Therefore, an appropriate monitoring system for the tunnel construction should be setup at the planning or design stage. A number of studies on ground settlements due to tunnelling in soft ground have been carried out so far. However, most studies have focused on clay soil rather than sand soil. In particular, a few studies on behaviour of subsurface deformations in granular material have been reported. In this study, two-dimensional laboratory model test with aluminium rods regarded as continuum granular material and close range photogrammetric technique, and numerical analysis were carried out in order to identify the behaviour of subsurface deformations due to shallow tunnelling. Direction and magnitude of displacement vectors from the model test was identical to the numerical analysis. In particular, the vector direction was appeared to be toward a point below the tunnel invert level. A narrow 'chimney or tulip like' pattern of vertical displacement was confirmed by both the model test and numerical analysis. This is consistent with the field data. In addition to the qualitative comparison, the quantitative comparison of subsurface settlements according to 2D volume loss showed good agreement between the model test and numerical analysis. Therefore, close range photogrammetric technique applied in the model test may be used to validate the result from the continuum numerical analysis.

  • PDF

Image-Guided Radiotherapy for Target Localization in Prostate Cancer with Implanted Markers

  • Suh, Ye-Lin;Park, Sung-Ho;Ahn, Seung-Do;Kim, Jong-Hoon;Lee, Sang-Wook;Shin, Seong-Soo;Choi, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.68-70
    • /
    • 2005
  • To precisely localize target in prostate cancer, image-guided radiotherapy was performed using the $ExacTrac^{\circledR}$ x-ray system (Brainlab, Germany) with implanted markers. For three prostate cancer patients, three gold markers were implanted into prostate. Orthogonal portal images were acquired every treatment and CT scans were repeated 3~5 times during the course of treatment. After correcting setup errors calculated by the system, the position of the implanted markers and the distance between them were detected in daily portal images and in CT images, and analyzed retrospectively. Deviation of the relative position of the implanted markers and the distance between them were less than 1 mm in lateral, longitudinal, and vertical direction for three patients, both in portal images and CT images. This study reveals that image-guided radiotherapy using the $ExacTrac^{\circledR}$ system is useful to verify positioning errors and localize prostate target with implanted markers, reducing the planning target volume (PTV) margin as well as irradiation to rectum and bladder.

  • PDF

A Heuristic for Service-Parts Lot-Sizing with Disassembly Option (분해옵션 포함 서비스부품 로트사이징 휴리스틱)

  • Jang, Jin-Myeong;Kim, Hwa-Joong;Son, Dong-Hoon;Lee, Dong-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.2
    • /
    • pp.24-35
    • /
    • 2021
  • Due to increasing awareness on the treatment of end-of-use/life products, disassembly has been a fast-growing research area of interest for many researchers over recent decades. This paper introduces a novel lot-sizing problem that has not been studied in the literature, which is the service-parts lot-sizing with disassembly option. The disassembly option implies that the demands of service parts can be fulfilled by newly manufactured parts, but also by disassembled parts. The disassembled parts are the ones recovered after the disassembly of end-of-use/life products. The objective of the considered problem is to maximize the total profit, i.e., the revenue of selling the service parts minus the total cost of the fixed setup, production, disassembly, inventory holding, and disposal over a planning horizon. This paper proves that the single-period version of the considered problem is NP-hard and suggests a heuristic by combining a simulated annealing algorithm and a linear-programming relaxation. Computational experiment results show that the heuristic generates near-optimal solutions within reasonable computation time, which implies that the heuristic is a viable optimization tool for the service parts inventory management. In addition, sensitivity analyses indicate that deciding an appropriate price of disassembled parts and an appropriate collection amount of EOLs are very important for sustainable service parts systems.

Effect of Planting Patterns on the Cultivation of Eggplant (Solanum melongena) and Marigold (Tagetes erecta) for the Activation of Eco-Friendly Rooftop Urban Agriculture (친환경 옥상 도시농업 활성화를 위한 배식모형에 따른 가지(Solanum melongena)와 메리골드(Tagetes erecta) 식재효과)

  • Jae-Hyun Park;Sang-Il Seo;Deuk-Kyun Oh;Yong-Han Yoon;Jin-Hee Ju
    • Journal of Environmental Science International
    • /
    • v.33 no.6
    • /
    • pp.417-425
    • /
    • 2024
  • This study investigated the effects of various planting models on the joint cultivation of eggplant (Solanum melongena) and marigold (Tagetes erecta)to enhance sustainable rooftop urban farming. Rooftop agriculture is increasingly valued to boost the food supply and benefit the environment. Integrating such practices into urban planning is viewed as a way to sustainably manage resources and improve the food-energy-water cycle in cities. The experiment was conducted on a rooftop in Chungju, South Korea from May to August. Four different planting setups were used: central eggplant with peripheral marigold (SET), eggplant with a protective net (SIC), central marigold with peripheral eggplant (TES), and control with only eggplant (CON S). These models tested the effects of companion planting versus monoculture using a lightweight soil mix ideal for rooftops made from cocopeat and perlite and enriched with organic fertilizer. Measurements focused on soil conditions and plant health and assessed soil temperature, moisture, conductivity, plant height, width, and leaf size. The results indicated that the SET modelyielded the best growth. This setup benefited from marigold pest control properties and its ability to improve soil conditions by enhancing moisture and nutrient levels and aiding eggplant growth. These findings underscore the potential of mixed planting on rooftops and suggest that such approaches can be effectively incorporated into urban agriculture to boost yield and environmental sustainability. This study supports the idea that diverse planting methods can significantly affect plant growth and promote urban greening and food security.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity (공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교)

  • Kim, Yon-Lae;Suh, Tae-Suk;Ko, Shin-Gwan;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study is compared that the dose distribution by experimentation and radiation therapy planning (RTP) when the air cavity region was treated high energy photon. The dose measurements were performed with a 6 MV photon beam of linear accelerator. The polystyrene and self made acyl phantom were similar to tissue density of the human body. A parallel plate chamber was connected to an electrometer. The measurement setup was SCD (Source Chamber Distance) 100 cm and the distance of surface from air cavity was 3 cm. Absorbed dose of interface were measured by area and height. The percent depth dose were measured presence and absence of air cavity, depth according to a ratio of field size and air cavity size. The dose distribution on planning was expressed to do the inhomogeneity correction. As the area of air cavity was increased, the absorbed dose were gradually reduced. It was slightly increased, when the height of air cavity was changed from 0 cm to 0.5 cm. After the point, dose was decreased. In case of presence of air cavity, dose after distal air cavity interface was more great than absence of air cavity. The rebuild up by field size and area of air cavity occurred for field size, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$ and $6{\times}6\;cm^2$, with fixed on area of air cavity, $5{\times}5\;cm^2$. But it didn't occur at $10{\times}10\;cm^2$ field size. On the contrary, the field size was fixed on $5{\times}5\;cm^2$, rebuild up occurred in area of air cavity, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$. but, it did not occur for air cavity, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$. All of the radiation therapy planning were not occurred rebuild up. It was required to pay attention to treat tumor in air cavity because the dose distribution of planning was different from the dose distribution of patient.