• 제목/요약/키워드: Set-pressure

검색결과 1,346건 처리시간 0.024초

냉난방수배관시스템용 차압독립형 유량제어밸브의 유동특성 연구 (A Study of Flow Characteristics in Pressure Independent Control Valve for Hydronic System)

  • 민준기;원보영;정신규
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권3호
    • /
    • pp.9-15
    • /
    • 2017
  • In this study, set values of PICV(Pressure Independent Control Valve) were simulated according to the pressure distribution and velocity. The higher the set value and the open rate, as the lower the pressure in the neck. On the contrary, the lower the set value and open rate, as the higher the pressure in the neck. When the set value was small, the pressure was distributed sufficiently and confirmed that the pressure was generated by the VOF, confirming that it could generate a vapor pressure. When the set value 100 %, the lower corn open rate of the differential pressure was 46 % to 29 %, set value 100 % was 29 % to 19 %, and set value 6 % was 12 % to 6 % for the lower corn open rate percentile, it was limited to within 50 %. Thus, the results of this study on the correlation between open rate and differential pressure of the set value of the PICV will be beneficial to improve performance of flow control valves and contribute to their efficient operation used for a hydronic system.

TOPOLOGICAL PRESSURE OF CONTINUOUS FLOWS WITHOUT FIXED POINTS

  • LEE, KYUNG-BOK
    • 대한수학회논문집
    • /
    • 제20권2호
    • /
    • pp.365-379
    • /
    • 2005
  • The purpose of this paper is to correct erroneous proofs of theorems of He, Lu, Wang and Zheng [1] about the topological pressure of continuous flows without fixed points and to give proofs of some results which are stated in the literature without proofs and thereby to show that their theorems are still true.

교대부양 설정압력 변화가 인체조직의 동적인 관류특성에 미치는 영향 (The Effects of Alternating Set Pressure Changes on Dynamic Tissue Perfusion Characteristics)

  • 원병희;송창섭
    • 대한인간공학회지
    • /
    • 제29권6호
    • /
    • pp.875-887
    • /
    • 2010
  • The quantitative effectiveness of powered support surfaces such as APAM in preventing and treating pressure ulcers has not been sufficiently evaluated because of uncertainty of alternating pressure load input and lack of interpretation of dynamic perfusion characteristics of soft tissue. The aim was to verify the dynamic loading effects to sacral tissue perfusion characteristics from alternating set pressure changes. We developed integrated experiment system to supply alternating load to supinely positioned sacrum and concurrently measured $TcPO_2$, $TcPCO_2$ and air cell pressure. Ten aged subjects (5 female, 5 male) were tested with alternating set pressure 20, 30, 40, 50 and 60mmHg. From the dynamic perfusion response eight characteristic parameters were proposed such as average, minimum, maximum and perfusion range regarding to $TcPO_2$ and $TcPCO_2$. A one-way ANOVA was carried out to determine whether the manipulation of alternating set pressure had any effect on $TcPO_2$ and $TcPCO_2$. From the dynamic tissue perfusion response we found mean $TcPO_2$ decreased exponentially as alternating pressure load increased and perfusion range varied mainly because of minimum level change of $TcPO_2$. And perfusion range of $TcPCO_2$ affected by increase of maximum value of $TcPCO_2$. From the results we can get more strict insights about actual physiological dynamic tissue perfusion mechanism under alternating pressure load.

Effect of Difference in Warm-Up Intensity During 75%1RM Bench Press Exercise on Number of Repetitions, Total Work, and RPP

  • Jeong, Hwan Jong;Kim, Ki Hong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권3호
    • /
    • pp.130-136
    • /
    • 2021
  • The purpose of this study was to investigate the effect of the intensity of warm-up exercise on the physiological response and exercise performance during resistance exercise. For this purpose, 8 male college students with at least 1 year of experience in resistance movement were selected. The warm-up condition was set to NON condition (preparatory exercise not performed), 3 set condition, 6 set condition, and 9 set condition, and the intensity was different for each set. After warm-up, 75% 1RM of main exercise was performed, and blood pressure and heart rate were measured immediately after exercise to measure RPP. The number of repetitions and total work for each condition were measured as the number of repetitions and momentum during the main exercise. The measured data were analyzed by repeated measures two-way ANOVA. As a result, although there was no difference in Rate Pressure Product according to the warm-up conditions, the number of repetitions and total amount of exercise showed the highest in the 3-set condition. Therefore, it is thought that the number and intensity of warm-up exercises should be set appropriately during resistance exercise, and warm-up of 3 sets or more during resistance exercise is thought to decrease exercise performance.

Microfiltration Helical Module들에서 Hollow Fiber의 Diameter과 Curvature 및 Turn수의 변화에 따른 성능변화에 관한 연구 (The Effect of the Variation of Hollow Fiber Diameter and Curvature and Turn Number on Performance for Microfiltration Helical Modules)

  • 이광현
    • 멤브레인
    • /
    • 제7권2호
    • /
    • pp.84-94
    • /
    • 1997
  • Hollow fiber의 diameter와 curvature 및 turn수 등의 변화에 따른 첫번째 모듈 set와 두번째 모듈 set 사이의 성능비교가 이루어졌다. 모든 실험들은 같은 transmembrane pressure와 막면적당 에너지 소모하에서 수행되었다. 첫번째 모듈 set에 대해서 Dean vortices에 의한 농도분극과 막오염현상의 감소시키는 효과가 매우 작음을 알 수 있었다. 두번째 모듈 set에 대해서 115%의 투과 flux 향상값 (투과 flux 증분 ${\times}100$/선형 모듈의 투과 flux)을 보였다. 이로부터 두번째 모듈 set가 yeast suspension에 의한 농도분극과 막오염현상의 감소에 훨씬 효과적임을 알 수 있었다.

  • PDF

원자력 증기용 안전밸브의 개방성능 평가를 위한 해석적 연구 (An Analytical Study on Evaluation of Opening Performance of Steam Safety Valve for Nuclear Power Plant)

  • 손상호
    • 한국유체기계학회 논문집
    • /
    • 제17권1호
    • /
    • pp.5-11
    • /
    • 2014
  • The purpose of this paper is to investigate an analytical approach for opening performance evaluation of the nuclear pressure safety valve based on standard codes such as ASME or KEPIC. It is well-known that safety valve is considered as one of pressure relief valves for protecting a boiler or pressure vessel from exceeding the maximum allowable working pressure. When pressure in a container reaches its set pressure, the safety valve commences discharging the internal fluid by a sudden opening called as popping. Safety valve is usually evaluated by set pressure, full open, blow-down, leakage and flow capacity. The test procedure and technical requirement for performance evaluation is described in international code of ASME code such as BPVC. The opening characteristics of steam safety valve can be analyzed by computational fluid dynamics (CFD) and steam shaft dynamics. First, the flow analysis along opening process is simulated by running the CFD models of the ten types of opening steps from 0 to 100%. As a analysis result, the various CFD outputs of flow pattern, pressure, forces on the disc and mass flow at each simulation step is demonstrated. The lift force is calculated by using the forces applied on disc from static pressure and secondary flow. And, the effect of huddle chamber or control chamber is studied by dynamic analysis based on CFD simulation results such as lift force. As a result, dynamics analysis shows opening features according to the sizes of control chamber.

Die design system for deep drawing and ironing of high pressure gas cylinder

  • Yoon Ji-Hun;Choi Young;Park Yoon-So
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권4호
    • /
    • pp.31-36
    • /
    • 2005
  • This paper describes a research work on the die design for the deep drawing & ironing(D. D. I) of high pressure gas cylinder. D. D. I die set is large-sized die used in horizontal press, which is usually composed of a drawing, and an ironing die. Design method of D. D. I die set is very different from that of conventional cold forging die set. Outer diameter of the die set is fixed because of press specification and that of the insert should be as small as possible for saving material cost. In this study, D. D. I die set has been designed to consider those characteristics, and the feasibility of the designed die has been verified by FE-analysis. In addition, the automated system of die design has been developed in AutoCAD R14 by formulating the applied methods to the regular rules.

이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성 (Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers)

  • 서상룡;김항오;김영태;최영수;유수남
    • Journal of Biosystems Engineering
    • /
    • 제31권1호
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.

파워시프트 변속기 유압클러치시스템의 해석적 연구 (An Analytical Investigation of a Hydraulic Clutch System of Powershift Transmission)

  • 이재천
    • 유공압시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 2009
  • This study presents an analytical model of hydraulic clutch system of a power shift transmission to analyze pressure modulation characteristics. A typical hydraulic clutch system was modeled by using AMESim in which the parameters of major components were measured for simulation. Test apparatus was established using the components of power shift and power shuttle clutches with instrumental equipment. The results of simulation and experiment were so close that the proposed analytical model in this study was validated. However the cylinder model analogized clutch dynamics need to be improved in future study. The effects of parameters of orifice diameter, accumulator stroke and oil temperature on pressure modulation were analyzed respectively. The results of parameter sensitivity analysis show that modulation time and set pressure can be easily adjusted by changing parameter values. It is also found that the hydraulic clutch system used in this study is so susceptible to oil temperature that cooling equipment is necessary.

  • PDF

혈압측정시 가압 단계에서 목표압력 및 측정 종료압력 추정 (Estimation of Target and Completion Pressure during the Cuff Inflation Phase in Blood Pressure Measurement)

  • 오홍식;이종실;김영수;신동범;김인영;지영준
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권5호
    • /
    • pp.371-375
    • /
    • 2008
  • In blood pressure measurement, the oscillometric method detects and analyzes the pulse pressure oscillation while deflating the cuff around the arm. For its principle, one has to inflate cuff pressure above the subject's systolic pressure and deflate below the diastolic pressure. Most of the commercialized devices inflate until the fixed target pressure and deflate until the fixed completion pressure because there is no way to know the systolic and diastolic pressure before measurement. Too high target pressure makes stress to the subject and too low target pressure makes big error or long measurement time because of re-inflation. There are similar problems for inadequate completion pressure. In this study, we suggest new algorithm to set proper target and completion pressure for each subject by analyzing pressure waveform while inflating period. We compared our proposed method and auscultation method to see the errors of estimation. The differences between the two measurements were -4.02$\pm$4.80mmHg, -10.50$\pm$10.57mmHg and -0.78$\pm$5.l7mmHg for mean arterial pressure, systolic pressure and diastolic pressure respectively. Consequently, we could set the target pressure by 30 mmHg higher than our estimation and we could stop at 20mmHg lower than our estimated diastolic pressure. Using this method, we could reduce the measurement time.