• Title/Summary/Keyword: Set value test

Search Result 608, Processing Time 0.029 seconds

Development of Radiation Free Soft X-Ray Ionizer with Ion Control (완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발)

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.

Comparing Survival Functions with Doubly Interval-Censored Data: An Application to Diabetes Surveyed by Korean Cancer Prevention Study (이중구간중도절단된 생존자료의 생존함수 비교를 위한 검정: 한국인 암 예방연구 중 당뇨병에의 응용)

  • Jee, Sun-Ha;Nam, Chung-Mo;Kim, Jin-Heum
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.595-606
    • /
    • 2009
  • Two tests were introduced for comparing several survival functions with doubly interval-censored data and illustrated with data surveyed by Korean Cancer Prevention Study (Jee et al., 2005). The test which extended Kim et al. (2006)'s test to the doubly interval-censored data has an advantage over Sun (2006)'s test in terms of saving computation time because the proposed test only depends on the size of risk set, and also the proposed test is applicable to continuous failure time data as well as discrete failure time data unlike Sun's test. Comparing male with female groups on the incubation time of diabetes was highly different and the survival of female group was longer than that of male one. Regardless of gender, the difference in survival functions of four age groups was highly significant with p-value of less than 0.001. This trend was more remarkable for female group than for male one. Simulation results showed that the significance level of both tests was well controlled and the proposed test was better than Sun's test in terms of power.

Sentiment Analysis of Product Reviews to Identify Deceptive Rating Information in Social Media: A SentiDeceptive Approach

  • Marwat, M. Irfan;Khan, Javed Ali;Alshehri, Dr. Mohammad Dahman;Ali, Muhammad Asghar;Hizbullah;Ali, Haider;Assam, Muhammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.3
    • /
    • pp.830-860
    • /
    • 2022
  • [Introduction] Nowadays, many companies are shifting their businesses online due to the growing trend among customers to buy and shop online, as people prefer online purchasing products. [Problem] Users share a vast amount of information about products, making it difficult and challenging for the end-users to make certain decisions. [Motivation] Therefore, we need a mechanism to automatically analyze end-user opinions, thoughts, or feelings in the social media platform about the products that might be useful for the customers to make or change their decisions about buying or purchasing specific products. [Proposed Solution] For this purpose, we proposed an automated SentiDecpective approach, which classifies end-user reviews into negative, positive, and neutral sentiments and identifies deceptive crowd-users rating information in the social media platform to help the user in decision-making. [Methodology] For this purpose, we first collected 11781 end-users comments from the Amazon store and Flipkart web application covering distant products, such as watches, mobile, shoes, clothes, and perfumes. Next, we develop a coding guideline used as a base for the comments annotation process. We then applied the content analysis approach and existing VADER library to annotate the end-user comments in the data set with the identified codes, which results in a labelled data set used as an input to the machine learning classifiers. Finally, we applied the sentiment analysis approach to identify the end-users opinions and overcome the deceptive rating information in the social media platforms by first preprocessing the input data to remove the irrelevant (stop words, special characters, etc.) data from the dataset, employing two standard resampling approaches to balance the data set, i-e, oversampling, and under-sampling, extract different features (TF-IDF and BOW) from the textual data in the data set and then train & test the machine learning algorithms by applying a standard cross-validation approach (KFold and Shuffle Split). [Results/Outcomes] Furthermore, to support our research study, we developed an automated tool that automatically analyzes each customer feedback and displays the collective sentiments of customers about a specific product with the help of a graph, which helps customers to make certain decisions. In a nutshell, our proposed sentiments approach produces good results when identifying the customer sentiments from the online user feedbacks, i-e, obtained an average 94.01% precision, 93.69% recall, and 93.81% F-measure value for classifying positive sentiments.

Evaluation of color matching ability according to the color temperature and the experience of practitioner (색 온도 및 술자의 숙련도에 따른 비색 능력 평가 원저)

  • Kim, Ji-Hyun;Kim, Sun-Jai;Lee, Keun-Woo;Shim, June-Sung;Yoon, Joonho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.299-304
    • /
    • 2012
  • Purpose: The aim of this study is to investigate the effect of different experience level and different light source on shade selection ability comparing prosthodontist group and dental student group under 4,000 K and 5,500 K light. Materials and methods: After color difference of Vitapan 3D-master shade guides was measured, 3 sets of 5 shade tabs were selected with similar value but have different chroma (set a, b, c). Also 3 sets of 5 shade tabs were selected with similar chroma but have different values (set d, e, f). Under 4,000 K and 5,500 K light sources, ten prosthodontists and ten dental students were allowed to match in one set of 5 tabs the same shade tab with the tab which was originally selected in the other set of 5 tabs. Color differences of original tab and matched tab were measured by spectrophotometer and the shade selection ability was evaluated with those data. Evaluation of color difference value was performed in regard to different light conditions and different level of experience, followed by t-test with 95% confidence interval. Results: Color difference values under 4,000 K and 5,500 K light source were $1.62{\pm}2.0$, and $1.33{\pm}1.7$ respectively. In addition, color difference values of prosthodontist group and dental student group were $1.34{\pm}1.7$, and $1.61{\pm}2.0$ respectively. Difference of shade selection ability was not found under either different light sources (P=.398), or different experience level (P=.221). Conclusion: Level of experience did not affect on the shade selection ability when prosthodontists and dental students matched the shades with the same shade tab under the same light source.

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

Estimation of Soft Ground Piezocone Factors at Gwangyang, Jeonnam (전남 광양지역 연약지반의 피에조콘계수 산정)

  • Oh, Dongchoon;Kim, Kibeom;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.2
    • /
    • pp.59-67
    • /
    • 2019
  • Using the results from laboratory soil test, field vane test and piezocone penetration test, the engineering characteristics of the soft ground at east side of Gwangyang Port, which is located at south coast of Jeollanam-do, were investigated and optimal piezocone penetration test depth was derived to calculate piezocone factor. In this paper, the results of 61 laboratory soil tests, 226 times of field vane tests and 26 piezocone penetration tests were used. The result of laboratory soil test suggested that some physical properties such as specific gravity, moisture content, liquid limit and plastic index and others are higher than other south coast regions, meanwhile uniaxial compression strength, undrained shear strength, defined as mechanical property, appeared to be relatively small, distributed widely. According to the plastic chart, the ground was classified as high compressibility clay and low compressibility clay, mostly represent to Type 3 clay by Robertson (1990)'s classification chart. Piezocone factor was calculated by empirical method, based on the undrained shear strength which was obtained by the field vane test. According to the analysis with 3 different depth range, to set the appropriate measured depth range of piezocone penetration for comparation, using average value of the range of 5 times the vane length showed the highest correlation.

Quality Characteristics of Madeleine Added with Mulberry Powder According to Drying Conditions (건조조건에 따른 오디분말을 첨가한 마들렌의 품질특성)

  • Lee, Min-Ae;Park, Mi-Lan;Byun, Gwang-In
    • Culinary science and hospitality research
    • /
    • v.19 no.4
    • /
    • pp.13-24
    • /
    • 2013
  • This research intends to examine the quality characteristics of madeleines after adding drying frozen mulberries by freeze drying and hot-air drying, making them powdered. The general ingredients and physiochemical characteristics of each specimen were measured, compared and analyzed. Madeleines were made based on the recipe set in practical examination of bakery technicians, in which each specimen is added with 0%(control), 1%, 3%, 5%, 7% of mulberry powder depending on the quantity of flour. And then, pH, chromaticity and texture were measured and consumer preferences were grasped by sensory testing. The test results are as follows. First of all, pH was low in the group added with hot-air drying mulberry powder. In chromaticity, brightness(L value) was reduced in comparison with the control group as the addition rates of freeze-drying mulberry powder and hot-air drying mulberry powder increased. Red chromaticity(a value) increased more when adding hot-air drying mulberry powder rather than freeze-drying mulberry powder. Yellow chromaticity(b value) was reduced as addition of mulberry powder increased. Hardness and elasticity of the group added with freeze-drying mulberry powder showed significant differences as addition of mulberry powder increased. Cohesiveness and gumminess was reduced as the addition increased. Hardness of madeleines added with hot-air drying mulberry powder showed significant differences by addition rates of mulberry powder. Elasticity increased by the quantity of mulberry addition. Cohesiveness was reduced as the addition was reduced. Gummines increased as the addition increased. As the result of sensory test on preference, the preferences of the group added with 5% of freeze-drying mulberry powder and the group added with 7% of hot-air drying mulberry powder were the highest.

  • PDF

A Study on the Long-Run Consumption Risk in Foreign Currency Risk Premia (장기소비 위험을 이용한 통화포트폴리오 수익률에 관한 연구)

  • Liu, Won-Suk;Son, Sam-Ho
    • Journal of Distribution Science
    • /
    • v.11 no.10
    • /
    • pp.55-62
    • /
    • 2013
  • Purpose - The purpose of this study is to suggest a risk factor that significantly explains foreign currency risk premia. In recent years, some studies have found that the performance of the simultaneous consumption risk model improves considerably when tested on foreign currency portfolios, which are constructed based on the international interest rates differentials. However, this paper focuses on the long-run consumption risk factor. In our empirical research, we found that the real excess returns of high interest rate currency portfolios depreciate on average, when the future American long-run consumption growth rate appears low. This makes the high interest rate currency portfolios have relatively high risk premia. Meanwhile, the real excess returns of low interest rate currency portfolios appreciate on average, under the same conditions, which results in relatively low risk premia for these portfolios. Therefore, this long-run consumption risk factor might explain why low interest rate currencies do not appreciate as much as the interest rate differential, and why high interest rate currencies do not depreciate as much as the interest rate differential. Research design, data, methodology - In our explanation, we provide new evidence on the success of long-run consumption risks in currency risk premia by focusing on the long-run consumption risks borne by American representative investors. To uncover the hidden link between exchange rates and long-run consumption growth, we set the eight currency portfolios as our basic assets, which have been built based on the foreign interest rates of eighty countries. As these eight currency portfolios are rebalanced every year, the first group always contains the lowest interest rate currencies, and the last group contains the highest interest rate currencies. Against these basic eight currency portfolios, we estimate the long-run consumption risk model. We use recursive utility framework and the stochastic discount factor that depends on the present value of expected future consumption growth rates. We find that our model is optimized in the two-year period of constructing the durable consumption expectation factor. Our main results surprisingly surpass the performance of the existing benchmark simultaneous consumption model in terms of R2, relatively risk aversion coefficient γ, and p-value of J-test. Results - The performance of our model is superior. R2, relatively risk aversion coefficient γ, and p-value of J-test of our long-run durable consumption model are 90%, 93%, and 65.5%, respectively, while those of EZ-DCAPM are 87%, 113%, and 62.8%, respectively. Thus, we can speculate that the risk premia in foreign currency markets have been determined by the long-run consumption risk. Conclusions - The aggregate long-run consumption growth risk explains a large part of the average change in the real excess returns of foreign currency portfolios. The real excess returns of high interest rate currency portfolios depreciate on average when American long-run consumption growth rate is low, and the real excess returns of low interest rate currency portfolios appreciate under the same conditions. Thus, the low interest rate currency portfolios allow investors to hedge against aggregate long-run consumption growth risk.

Improvement of Control Characteristics of Permanent Magnet Linear Synchronous Motor by Finite Element Analysis (유한요소 해석에 의한 영구자석형 선형 동기전동기의 제어특성 개선)

  • 정인성;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.318-324
    • /
    • 1999
  • In this paper. a control method based on finite element analysis is presented to improve the control characteristics of t the permanent magnet linear synchronous motor (PMLSM). In the control method. additional compensation current is a added to the conventional control current according to the position of mover. The characteristics of thrust ripple a according to the position of mover and the current are analyzed by using finite element method (FEM). And. the value of current to compensate the thrust ripple due to the cog밍ng force is calculated from the analysis results. The c characteristics according to control method are compared in case of speed control. and to conform the validity of the p presented method, a test set is built and experiments are performed.

  • PDF

3D QSAR Study of 2-Methoxyphenylpiperazinylakanamides as 5-Hydroxytryptamine (Serotonin) Receptor 7 Antagonists

  • Nagarajan, Santhosh Kumar;Madhavan, Thirumurthy
    • Journal of Integrative Natural Science
    • /
    • v.9 no.2
    • /
    • pp.128-135
    • /
    • 2016
  • 5-hydroxytryptamine (serotonin) receptor ($5-HT_7R$) 7 is one of G-Protein coupled receptors, which is activated by the neurotransmitter Serotonin. After activation by serotonin, $5-HT_7$ activates the production of the intracellular signaling molecule cyclic AMP. $5-HT_7$ receptor has been found to be involved in the pathophysiology of various disorders. It is reported that $5-HT_7$ receptor antagonists can be used as antidepressant agents. In this study, we report the important structural and chemical parameters for 2-methoxyphenylpiperazinylakanamides as $5-HT_7R$ inhibitors. A 3D QSAR study based on comparative molecular field analysis (CoMFA) was performed. The best predictions were obtained for the best CoMFA model with $q^2$ of 0.594 with 6 components, $r^2$ of 0.986, Fisher value as 60.607, and an estimated standard error of 0.043. The predictive ability of the test set was 0.602. Results obtained the CoMFA models suggest that the data are well fitted and have high predictive ability. The contour maps are generated and studied. The contour analyses may serve as tool in the future for designing of novel and more potent $5-HT_7R$ derivatives.