• Title/Summary/Keyword: Set Screw

Search Result 74, Processing Time 0.026 seconds

Mandibular 4 incisors implant restoration (하악 4전치 상실 시 임플란트 수복)

  • Park, Jong hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.2
    • /
    • pp.56-63
    • /
    • 2022
  • The mandibular 4 anterior incisor restoration has small teeth and a small space, so the choice of abutment is always a concern. The mandibular 4 anterior incisor extraction is caused by periodontal disease, interdental embrasure greatly open is advantageous of oral hygiene management. Try to make it small diameter with custom abutment, it is limited to the space for the screw. Rather than setting the post site of one body implant to a horizontal cross-section, it is advantageous to set it to a longitudinal cross-section, for interdental embrasure formation. When using an internal bone level implant, rather than using a two-piece abutment, using a one-piece abutment can more effectively secure space for interdental embrasure.

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT (골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석)

  • Kim, Young-Il;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length (다양한 길이의 two-component 미니 임플란트의 응력분산에 대한 3차원적 유한요소분석)

  • Choi, Bohm;Lee, Dong-Ok;Mo, Sung-Seo;Kim, Seong-Hun;Park, Ki-Ho;Chung, Kyu-Rhim;Nelson, Gerald;Han, Seong-Ho
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.423-430
    • /
    • 2011
  • Objective: To evaluate the extent and aspect of stress to the cortical bone after application of a lateral force to a two-component orthodontic mini-implant (OMI, mini-implant) by using three-dimensional finite element analysis (FEA). Methods: The 3D-finite element models consisted of the maxilla, maxillary first molars, second premolars, and OMIs. The screw part of the OMI had a diameter of 1.8 mm and length of 8.5 mm and was placed between the roots of the upper second premolar and the first molar. The cortical bone thickness was set to 1 mm. The head part of the OMI was available in 3 sizes: 1 mm, 2 mm, and 3 mm. After a 2 N lateral force was applied to the center of the head part, the stress distribution and magnitude were analyzed using FEA. Results: When the head part of the OMI was friction fitted (tapped into place) into the inserted screw part, the stress was uniformly distributed over the surface where the head part was inserted. The extent of the minimum principal stress suggested that the length of the head part was proportionate with the amount of stress to the cortical bone; the stress varied between 10.84 and 15.33 MPa. Conclusions: These results suggest that the stress level at the cortical bone around the OMI does not have a detrimental influence on physiologic bone remodeling.

Quality Characteristics of Reconstituted Multi-Grain by Extrusion Process (압출성형기법에 의해 제조한 재성형 혼합곡의 품질특성)

  • Lee, Young-Tack;Seog, Ho-Moon;Kim, Sung-Soo;Kim, Kyung-Tack;Hong, Hee-Do
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.963-968
    • /
    • 1997
  • Cereals and legumes were ground, blended and extruded with a twin-screw extruder to form a reconstituted grain. The basic formula was as follows: brown rice 30%, barley 30%, wheat 20%, millet 5%, sorghum 5%, soybean 7%, and red bean 3%. Extrusion conditions were properly set for feed moisture content of $24{\sim}30%$, barrel temperature of $50{\sim}60^{\circ}C$, and screw speed at 250 rpm. The extruded grain was air-dried and evaluated for quality characteristics, compared with milled rice. Size and shape of the reconstituted grain were similar to short-grain milled rice. Stacking volume of the reconstituted grain was a little higher than that of milled rice, and its water absorption was more rapid. From the texture measurements, hardness of cooked reconstituted grain was slightly lower and adhesiveness was appeared to be higher.

  • PDF

Detailed Design for 25bar-class Biogas Compression Supplying System (25BAR급 바이오가스 고압 압축공급시스템 상세설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yun, Eun-Young;Lee, Jung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

Technology Trends and Patents Analysis of Auger bit for Deep Cement Mixing (DCM) Method (심층혼합처리 공법용 오거비트의 기술동향 및 특허분석)

  • Min, Kyongnam;Lee, Dongwon;Lee, Jaewon;Kim, Keeseok;Yu, Jihyung;Jung, Chanmuk;Hoang, Truong Xuan;Kwon, Yong Kyu
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.431-441
    • /
    • 2018
  • To set up the future research and development direction for Auger bit, this study analyzed publicized patent trends of Deep Cement Mixing method (DCM) in Korea, USA, Japan, and Europe. DCM method was firstly classified into wing shapes and the number of rods according to the technical scope, and secondly, classified into 8 types according to type of screw and rotation axial. A total of 2,815 patents were searched and 448 validated patents were selected through de-duplication and filtering. As a result of the analysis of the portfolio through the number of patents and growth stages, it was selected as the core technology that auger is deemed to have high growth potential and if there is a patent similar to core technology through a patent barrier analysis, the basic data is suggested to develop the design around and differentiated technologies.

Analysis of End-Plated Propellers by Panel Method (패널법에 의한 날개끝판부착 프로펠러의 해석)

  • C.S. Lee;I.S. Moon;Y.G. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.55-63
    • /
    • 1995
  • This paper describes the procedure to analyze the performance of the end-plated propeller(EPP) by a boundary integral method. The screw blade(SB) and end-plate(EP) are represented by a set of quadrilateral panels, where the source and normal dipole of uniform strength are distributed. The perturbation velocity potential, being the only unknown via the potential-based formulation, is determined by satisfying the flow tangency condition on the blade and the end-plate at the same time. The Kutta condition is satisfied through an iterative process by requiring the null pressure jump across the upper and lower sides of the trailing edges of both the SH and the EP. Sample calculations indicate that the EP increases the loading near the tip of the SB while spreading the trailing vortices along the trailing edge of the EP, thus avoiding the strong tip-vortex formation. Predicted performance of the EPP shows good correlations with the experimental results. The method is therefore considered applicable in designing and analyzing the EPP which may be an alternative for energy-saving propulsive devices.

  • PDF

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Optimization of extrusion cooking conditions for seasoning base production from sea mustard (Undaria pinnatifida)

  • Lee, Chaehyeon;Shin, Eui-Cheol;Ahn, Soo-Young;Kim, Seonghui;Kwak, Dongyun;Kwon, Sangoh;Choi, Yunjin;Choi, Gibeom;Jeong, Hyangyeon;Kim, Jin-Soo;Lee, Jung Suck;Cho, Suengmok
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.3
    • /
    • pp.175-186
    • /
    • 2022
  • Sea mustard (Undaria pinnatifida), an important edible seaweed belonging to the brown algal family of Alariaceae, contains copious physiologically active substances. It has long been popular in Korea as a food and is frequently consumed in the form of soup. It is also commercially available as a home meal replacement. In this study, we developed a seasoning key base with a high degree of sensory preference from sea mustard using the extrusion cooking process. Extrusion cooking conditions were optimized through response surface methodology. Barrel temperature (X1, 140℃-160℃) and screw speed (X2, 158-315 rpm) were set as independent variables, and overall preference was determined as the dependent variable (Y, points). An optimal condition was obtained at X1 = 148.5℃ and X2 = 315 rpm, and the dependent variable (Y, overall acceptance) was 7.95 points, similar to the experimental value of 7.81. Umami taste had a relationship with the overall acceptance of sea mustard seasoning. In the electronic nose and tongue, increased sourness and umami intensities were associated with the highest sensory score. The samples were separated well by each characteristic via principal component analysis. Collectively, our study provides imperative preliminary data for the development of various seasonings using sea mustard.

MITIGATION OF MAXILLARY ANTERIOR TEETH PROTRUSION WITH CEREBRAL PALSY USING REMOVABLE APPLIANCE : A CASE REPORT (뇌성마비환자에서 가철성장치를 이용한 상악 전치부 돌출 완화 : 증례보고)

  • Min, Boram;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.9 no.2
    • /
    • pp.122-126
    • /
    • 2013
  • Cerebral palsy is one of the primary handicapping conditions of childhood. The prevalence of malocclusions in patients with cerebral palsy is approximately twice than in general population. Even though these high rates of malocclusions, most clinicians may feel uncomfortable about treating such problems to reduce inclination of anterior teeth because to reduce of protrusion makes to decrease risk of trauma. This is the case report about mitigation of maxillary anterior teeth protrusion in patient with cerebral palsy. A 14 year old boy who had cerebral palsy visited our dental hospital. He had severe protrusive maxillary anterior teeth and narrow arch form. He was experienced at using Castillo morales appliance in early childhood. He had mild mental retardation and was able to learn simple skills. He and his parents had willing to improve his dental problems. A gentle impression taking on maxilla was done. Removable appliance was made including median screw and labial bow. We provide a period of adaption for 3 weeks. After of anterior teeth through activation of labial bow was done once a month by dentist. The treatment carried out for 10 months and we could observe reduced labial inclination of maxillary right central incisor and more wide arch form. Hawley type retainer was set at maxilla for retention. In conclusion, accompanying careful case selection and treatment, patient with cerebral palsy can be treated and should not be ignored their orthodontic needs.