• Title/Summary/Keyword: Set Screw

Search Result 74, Processing Time 0.04 seconds

SKELETAL RELAPSE AFTER SAGITTAL SPLIT RAMUS OSTEOTOMY AND SCREW FIXATION (하악전돌증에서 하악지 시상분할골절단 및 Screw고정후 골성회귀에 관한 연구)

  • Lee, Chang-Kug;Kim, Myung-Rae;Choi, Jang-Woo;Yun, Jung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.563-569
    • /
    • 1996
  • Skeletal and dental changes were examined in 38 patients of mandibular prognathism who been treated by a bilateral sagittal split osteotomy(SSRO) and internal fixation using titanium mini-screws. All patients were followed up for over 8 months after the surgeries, and postoperative cephalometric measurements were compared at 2 months and at 8 months. Linear measurements of the "Pog-most posterior screws" and angular measurementsts of "SN-Pog'were compared to figure out the change of bony fragments. The significancy of data were tested by unpaired T-test. The results were as follows : 1. The fixation screws were changed in cephalometric position as little as $0.32{\pm}2.51mm$ in SSRO and $0.15{\pm}1.00mm$ in SSRO & Le Fort I Osteotomy.(P<0.05) 2. Mandibular set-back over 5mm resulted in less stability of the fixation screws and higher relapse tendency. 3. The internal fixation using two screws along the inferior border and one on the superior ridge is considered to be very resistant to postoperative relapse of the repositioned bony segments.

  • PDF

Numerical model for bolted T-stubs with two bolt rows

  • Daidie, Alain;Chakhari, Jamel;Zghal, Ali
    • Structural Engineering and Mechanics
    • /
    • v.26 no.3
    • /
    • pp.343-361
    • /
    • 2007
  • This article presents a numerical tool for dimensioning two-threaded fasteners connecting prismatic parts subjected to fatigue tension loads that are coplanar with the screw axis. A simplified numerical model is developed from unidirectional finite elements, modeling the connected parts and screws with bent elements and the elastic contact layer between the parts with springs. An algorithm updating the contact stiffness matrix, calculating forces and displacements at each node of the structure and thus normal stresses in the screws in both static and fatigue is further developed using C language. An experimental study is also conducted in parallel with the numerical approach to validate the developed model assumptions, the numerical model and the 3D finite element results. Since stiffness values for the compressive zones in the parts are analytically difficult to determine, a statistical software method is used, from which a tuning factor is derived for identifying these stiffness values. The method is also applied to set out the influence of each parameter on the fatigue behaviour of each screw. Finally, the developed model will be used to establish a new, sophisticated, fast and accurate tool for dimensioning bolted mechanical structures.

Cortical lag screw fixation for the management of mandibular injuries

  • Elsayed, Shadia Abdel-Hameed
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.393-402
    • /
    • 2020
  • Objectives: Here, we present cases of mandibular fracture that were managed with the cortical lag screw fixation technique (CLSFT) in order to critically evaluate technique indications and limitations of application at various fracture sites. Materials and Methods: This was a retrospective cohort study. The study sample was composed of patients suffering from mandibular fractures that were treated by the CLSFT. The outcome variables were fracture type, duration of surgery, number of screws, and pattern of application. Other study categories included patient demographics and causes of injury. Chi-square tests were used to assess descriptive and inferential statistical differences, and the P-value was set at 0.05. Results: Thirty-three patients were included in the study sample, with a mean age of 30.9±11.5 years and a male predominance of 81.8%. The technique was applied more frequently in the anterior mandibular region (51.5%) than in other sites. Double CLSFT screws were required at the symphysis and parasymphysis, while single screws were used for body and angle regions. No intraoperative and postoperative variables were significantly different except for surgical duration, which was significantly different between the sites studied (P=0.035). Conclusion: We found that CLSFT is a rapid, cost-effective technique for the fixation of mandibular fractures yielding good treatment results and very limited complications. However, this technique is sensitive and requires surgical expertise to be applied to mandibular fractures that have specialized characteristics.

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

The Tangential Projection Method for Checking Existence and Nonexistence of Radius Groove Penetration of Screw after Distal Radius Fracture Operation Used the T-type Plate (T형 금속판을 이용한 요골 원위부 골절 수술 후 나사못의 요골구 관통 유무를 확인하기 위한 접선방향 촬영법)

  • Seo, Sun-Youl;Hong, Ki-Jang;Han, Man-Seok;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.335-340
    • /
    • 2010
  • This paper is about a projection method to check existence of radius groove penetration of screw after distal radius fracture operation using the T-type plate. Angle of Radius groove was analyzed by fifty one CT images that contains patients' wrist and twenty cases of radius specimens. After making radius phantom by plaster, we set the screw so that it penetrated 2.4 mm depth of radius groove. Then, we projected the phantom by X-ray in change of the elevation and supination angle of distal radius by 5 degree interval on 0~30 degree. The average value of groove angle in the wrist CT images was 14.4 degree and the radius specimens was 16.3 degree. Screws penetrating radius groove of the phantom have different lengths according to elevation angle and supination angle. Consequently, in order to confirm existence and nonexistence of radius groove penetration of the screw in tangential projection after distal radius fracture operation using the T-type plate, we recommend 5 degree of elevation angle and 20 degree of supination angle.

Characteristics of the Dependent Variable due to Changes in the Conditions of the Independent Variable During the Producing of Collets Added with Rice and Dried Shrimp by Single Extruder (Single Extruder를 이용한 마른새우첨가 쌀 Collets 제조 시 독립변수의 조건변화에 따른 종속변수의 특성)

  • JE, Hae-Soo;YOON, Moon-Joo;LEE, Jae-Dong;KANG, Kyung-Hun;PARK, Si-Young;PARK, Jin-Hyo;KIM, Jeong-Gyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1352-1363
    • /
    • 2015
  • This study was carried out to investigate the characteristics of the dependent variables depending on the condition changes of independent variable of the operation and the material during the production of collets added with rice and dried shrimp by using single extruder to utilize as basic data for the manufacture of extrusion collets. A total of 7 independent variables were set up as a raw, 20, 40 and 60 mesh for the powder particle size of rice; 12, 14, 16 and 18% for the moisture content of rice; 2, 4, 6 and 8% for the addition amount of dried shrimp; 90, 95, 100 and $110^{\circ}C$ for the barrel temperature; 210, 280 and 340 rpm for the screw speed; 4, 6, 8 and 10 mm for the discharge port diameter; 30, 40, 50 and 60 kg/h for the input amount of the mixed material. The characteristics of the dependent variables including puffing ratio, moisture content, lightness, uniformity, productivity of collets was to be studied by changing the conditions of the independent variables. As a results of this study, 20 mesh of powder particle size of rice, 14% of moisture content of rice, 4% of addition amount of dried shrimp, $100^{\circ}C$ of barrel temperature, 280 rpm of screw speed, 6 mm of discharge port diameter and 50 kg/h of input amount of mixed material were found to be the most preferable over other independent variables for the production of extrusion collets. In conclusion, it is necessary to set the independent variable in order to produce the high quality collets added with the rice as the main raw material and dried shrimp as the sub-materials.

Development of Ridger and Vinyl Mulcher for Power Tiller (경운기 부착 휴립, 비닐 피복 동시작업기 개발)

  • 변정수;이은홍;강정용;류명현;홍순근
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.1
    • /
    • pp.57-62
    • /
    • 1993
  • Ridger and vinyl mulcher for 8-10 PS power tiller which were distributed at the rate of one out of 2.3 farm households in Korea, was developed to ease the labor shortage of tobacco production. Devices wheel shaft extension by 30cm at both sides improved the stability of straight drive and enabled to save required labor hours by 50% for ridging at sloping field. Screw type blades were attached on center drive rotavator shaft, gear set was deviled to reverse the rotavator, and it was good at need to adjust the width and height for ridge. As the results, required labor hours for ridging and vinyl mulching could be saved by 90% as compared to conventional manual method after cattle plowing, and by 50% as compared to conventional power tiller method.

  • PDF

A Sliding Mode Control for a Robot Manipulator with closed-chain Structure (폐체인 구조 로봇 머니퓰레이터의 슬라이딩모드 제어)

  • Choi Hyeung Sik;Baek Chagng Yul;Hwang I Chul;Kim Moo Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.98-108
    • /
    • 2005
  • Conventional robot manipulators actuated by motors with the speed reducer such as the harmonic drive have weakness in the load capacity, since the speed reducer does not have enough strength. To improve this, a new type of robot actuator based on the four-bar-link mechanism driven by the ball screw was constructed. Also, a new type of revolute robot manipulator composed of the developed actuators was developed. But, modelling errors occur due to the off-set from the nominal model since the exact modeling of the complex inertia variation of the four-bar-link actuator is very difficult. To control the proposed robot along the prescribed trajectory, a sliding mode control algorithm was applied with compensation function for the modeling errors. To show performance of the proposed controller, a computer simulation was performed, and its results was presented.

Effects of mushroom composition on the quality characteristics of extruded meat analog (버섯 첨가가 압출성형 대체육의 품질 특성에 미치는 영향)

  • Cho, Sun Young;Ryu, Gi-Hyung
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.4
    • /
    • pp.357-362
    • /
    • 2020
  • This study was conducted to investigate the effects of mushroom composition (0, 4, 8, and 12%) on the quality characteristics of an extruded meat analog. The meat analog blend was isolated soy protein, wheat gluten, and corn starch (50:40:10). The extrusion condition was set to 55% feed moisture, 170℃ barrel temperature, and 150 screw speed by high moisture extrusion using a twin-screw extruder equipped with a cooling die. The integrity index, hardness, cohesiveness, springiness, chewiness, and cutting strength of the meat analog increased with the increasing mushroom content, while its water holding capacity and nitrogen solubility index (NSI) decreased. The protein digestibility decreased with the increasing mushroom content, while the DPPH radical scavenging activity significantly increased. In conclusion, the incorporation of mushrooms into the investigated meat analog enhanced its texture and antioxidant level.