Design of Data Center Environmental Monitoring System Based On Lower Hardware Cost

  • Nkenyereye, Lionel;Jang, Jongwook
    • Journal of Multimedia Information System
    • /
    • v.3 no.3
    • /
    • pp.63-68
    • /
    • 2016
  • Environmental downtime produces a significant cost to organizations and makes them unable to do business because what happens in the data center affects everyone. In addition, the amount of electrical energy consumed by data centers increases with the amount of computing power installed. Installation of physical Information Technology and facilities related to environmental concerns, such as monitoring temperature, humidity, power, flood, smoke, air flow, and room entry, is the most proactive way to reduce the unnecessary costs of expensive hardware replacement or unplanned downtime and decrease energy consumed by servers. In this paper, we present remote system for monitoring datacenter implementing using open-source hardware platforms; Arduino, Raspberry Pi, and the Gobetwino. The sensed data displayed through Arduino are transferred using Gobetwino to the nearest host server such as temperature, humidity and distance every time an object hitting another object or a person coming in entrance. The raspberry Pi records the sensed data at the remote location. The objective of collecting temperature and humidity data allows monitoring of the server's health and getting alerts if things start to go wrong. When the temperature hits $50^{\circ}C$, the supervisor at remote headquarters would get a SMS, and then they would take appropriate actions to reduce electrical costs and preserve functionality of servers in data centers.

User Identification and Entrance/Exit Detection System for Smart Home (지능형 홈을 위한 사용자 식별 및 출입 감지 시스템)

  • Lee, Seon-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.3
    • /
    • pp.248-253
    • /
    • 2008
  • This paper presents a sensing system for smart home which can detect an location transition events such as entrance/exit of a member and identify the user in a group at the same time. The proposed system is compose of two sub-systems; a wireless sensor network system and a database server system. The wireless sensing system is designed as a star network where each of sensing modules with ultrasonic sensors and a Bluetooth RF module connect to a central receiver called Bluetooth access point. We propose a method to discriminate a user by measuring the height of the user. The differences in the height of users is a key feature for discrimination. At the same time, the each sensing module can recognize whether the user goes into or out a room by using two ultrasonic sensors. The server subsystem is a sort of data logging system which read the detected event from the access point and then write it into a database system. The database system could provide the location transition information to wide range of context-aware applications for smart home easily and conveniently. We evaluate the developed method with experiments for three subjects in a family with the installation of the developed system into a real house.

A study on the moving picture transmission method between the accident sites and control center (사고현장과 사령실간 화상전송기술에 관한 연구)

  • 장석각;조봉관
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.484-489
    • /
    • 2002
  • Whenever the accidents occur in the railway areas, their prompt recovery is very important. The individual way has been used to resolve these accidents by direct visiting the site and reporting to others who cares for these cases. As a result, we are planning to operate the MTS (Moving picture Transmission System) for a timely information's transmission to the related peoples in the central control center by transforming the picture information on the accident-site to the digital information. The proposed system is not a transmission system using exclusive lines, but utilizing the existing railway computer network. We construct a network server device so that a dispatcher can easily connect with the server through the railway intranet. In some railway environments such as disturbed field situations and geographical condition(in tunnels and bridges, etc) building up the wired network is difficult. Solving this problem, we reviewed the wireless network. Finally we proposed the mixed wireless network that is able to cover the wired network. We then installed and tested the wired network and wireless network respectively in wayside of a railway field. Through the testing, we identified many detailed matters for some network construction approaches to the control room and many field device-connecting schemes. This research will contribute to minimize the number of staff dispatched to a disturbed field, decrease the accident recovery time and improve the quality of service to the passenger.

  • PDF

Indoor Logistics Location Tracking System with Fingerprint (핑거프린트를 적용한 실내 물류 위치추적 시스템)

  • Kim, Doan;Jeon, Sung woo;Jung, Junhee;Bae, Sangjung;Jung, Heokyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.594-596
    • /
    • 2019
  • In this paper, we propose an indoor logistic tracking system that identifies the location and inventory of the logistics in the room based on fingerprints. Through this, we constructed the actual infrastructure of the logistics center and designed and implemented the logistics management system. The proposed system collects the signal strength through the location terminal and generates the signal map to locate the goods. The location terminal is composed of a UHF RFID reader and a wireless LAN card, reads the peripheral RFID signal and the signal of the wireless AP, and transmits it to the web server. This allows the user to communicate with the server through the smartphone app and get information and location of nearby items.

  • PDF

원격감시시스템을 이용한 증류공정의 안전운전

  • 최춘일;이성근;변윤섭;안대명;황규석
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.335-338
    • /
    • 2003
  • 최근의 통계에 따르면 국내의 인터넷 인용율은 2000년도에 44.7%, 2001년도에 56.6%, 2002년도에는 55.2%로 아이슬랜드(60.8%), 스웨덴(57.3%)에 이어 세계에서 세번째로 높은 것으로 나타났다. 또한 인구 100명당 PC보급율 또한 미국(62.5대), 덴마크(57.68대)에 이어 한국(55.58대)이 세계3위를 기록해 명실상부한 정보화 선진국임이 입증되고 있다. 따라서 잘 발달된 infrastructure을 이용하는 기술개발은 초고속정보이용을 가능케하고 있다. 근래에 들어 인터넷을 기반으로 기본적인 활용인 문자, 음성 및 영상 전송 등의 데이터 전송뿐만 아니라, 근래에는 인터넷을 통한 remote control 및 monitoring system에 대한 연구가 활발히 진행되고 있다. 기존의 증류공정은 DCS(Dispersion Control System)로써 공정상태(온도, 압력, 유량, 레벨, 순도등)를 Control room까지 선로를 통하여 신호전달이 이루어지고 있다. 따라서, 제한된 지역에서만 I/O(Input/output)이 이루어지고 있다. 이로 인해 안전감시시스템의 효율성이 떨어지고 있는 게 사실이다. 본 연구에서는 PC기반의 프로그램을 바탕으로 인터넷을 이용한 remote control 및 monitoring system을 개발함으로써 close Network에서 Open Network으로 발전시켰다. 여기서 local plant의 안전시스템 알고리즘은 그대로 Server system에 도입하였으며 사용자의 실정에 맞게 손쉽게 설정을 할 수 있도록 확장성을 높였다. 이는 PC기반의 시스템을 구축함으로써 가능하게 된 것이다. 또한, 웹 상에서의 무차별적 접근으로부터 보호하기 위하여 감시 대상의 성질에 따라 프로그램상에서 차별적 접근형식을 택할 수 있으며, control room의 indicator들과 controller를 프로그램상에 그대로 이식시킴으로써 감시자에게 충분한 정보제공 및 원격제어가 가능하도록 하고있다.

  • PDF

Performance Evaluation of the QoS Guarantee Mechanisms for Medical Multimedia Network Using DiffServ (DiffServ를 이용한 의료용 멀티미디어 네트워크의 QoS 보장에 대한 성능평가)

  • 이상학
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.12
    • /
    • pp.1505-1516
    • /
    • 2001
  • The goal of Medical multimedia server is to develop computer hardware and software which would enable electronic access, storage, transmission, and display of patient data and images. Since the current network only provides so called "best-effort" services, it is impossible to satisfy QoS guarantee that is required for real time application services for emergency room, operating room etc. Accordingly, world-wide research is being made for a variety of services to provide QoS. he goal of DiffServ is to offer scalable differentiated service in Internet which are made possible by traffic classification and conditioning only performed at an edge(or a boundary) node. In case DiffServ was deployed in the Medical multimedia network, it is difficult to estimate how the QoS mechanism would affect totally the network performance. Therefore, we need to verify by simulation the design of algorithm which provide a variety of differentiated services. In QoS for Medical multimedia network, a simulator is designed and implemented using OPNET to investigate the performance of DiffServ QoS support mechanism. The developed DiffServ simulator may generate packets according to random, and bursty traffic models in order to incorporate diverse traffic conditions in the Medical multimedia network environment. Based on our simulation results, we confirmed that service differentiation is possible by using the EF(Expedited Forwarding) class in DiffServ networks.

  • PDF

A Study on the Malfunction Prevention for Transponder of Record Type Fire Alarm System (R형 자탐설비의 중계기 오동작 방지 대책에 대한 연구)

  • Yoo, Jae Ick;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.54-59
    • /
    • 2014
  • The record type receivers that are operated in large industrial sites have strength in preventing fire. However, because of its long circuit lines and multiple detectors, the receivers are vulnerable to lightning, noise, and breakdown of equipments, resulting in malfunction. In case of malfunctioning of detection circuits of main protection areas, such as electrical room and server room, potential release of gaseous extinguisher agents may lead to property and life damage. In this paper, we present the results on the characteristics of the transponder that initiates the solenoid valves, with respect to various electromagnetic and lightning inflow conditions. Based on the measured data, we analyzed the systematic problems of the transponder. In order to prevent receiver malfunctions, a sequential circuit was configured with two additional transponders and a timer. The circuit was tested with a simulator with preference and delay circuit algorithms.

Implementation of Adaptive Movement Control for Waiter Robot using Visual Information

  • Nakazawa, Minoru;Guo, Qinglian;Nagase, Hiroshi
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.808-811
    • /
    • 2009
  • Robovie-R2 [1], developed by ATR, is a 110cm high, 60kg weight, two wheel drive, human like robot. It has two arms with dynamic fingers. It also has a position sensitive detector sensor and two cameras as eyes on his head for recognizing his surrounding environment. Recent years, we have carried out a project to integrate new functions into Robovie-R2 so as to make it possible to be used in a dining room in healthcare center for helping serving meal for elderly. As a new function, we have developed software system for adaptive movement control of Robovie-R2 that is primary important since a robot that cannot autonomously control its movement would be a dangerous object to the people in dining room. We used the cameras on Robovie-R2's head to catch environment images, applied our original algorithm for recognizing obstacles such as furniture or people, so as to control Roboie-R2's movement. In this paper, we will focus our algorithm and its results.

  • PDF

Numerical Analysis of Thermal Environment Control in High-Density Data Center (고밀도 데이터센터의 열환경제어를 위한 수치해석)

  • Kwon, Oh-Kyung;Kim, Hyeon-Joong;Cha, Dong-An
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.821-828
    • /
    • 2012
  • Increasing heat generation in CPUs can hamper effective recirculation and by-pass because of the large temperature difference between the exhaust and the intake air through a server room. This increases the overall temperature inside a data center and decreases the efficiency of the data center's cooling system. The purpose of the data center's cooling system is to separate the intake and exhaust air by controlling the computer room air-conditioner(CRAC). In this study, ICEPAK is used to conduct a numerical analysis of a data center's cooling system. The temperature distribution and the entire room are analyzed for different volumetric flow rates. The optimized volumetric flow rate is found for each CPU power. The heat removal and temperature distribution for CPU powers of 100, 120, and 140 W are found to be the best for a volumetric flow rate of $0.15m^3/s$. The numerical analysis is verified through RTI indicators, and the results appear to be the most reliable when the RTI value is 81.

Network vision of disaster prevention management for seashore reclaimed u-City (해안매립 신도시의 재해 예방관리 네트워크 비젼)

  • Ahn, Sang-Ro
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.117-129
    • /
    • 2009
  • This paper studied the safety management network system of infrastructure which constructed smart sensors, closed-circuit television(CCTV) and monitoring system. This safety management of infrastructure applied to bridge, cut slop and tunnel, embankment etc. The system applied to technologies of standardization guidelines, data acquirement technologies, data analysis and judgment technologies, system integration setup technology, and IT technologies. It was constructed safety management network system of various infrastructure to improve efficient management and operation for many infrastructure. Integrated safety management network system of infrastructure consisted of the real-time structural health monitoring system of each infrastructure, integrated control center, measured data transmission using i of tet web-based, collecting data using sf ver, early alarm system which the dangerous event of infrastructure occurred. Integrated control center consisted of conference room, control room to manage and analysis the data, server room to present the measured data and to collect the raw data. Early alarm system proposed realization of warning and response within 5 minute or less through development of sensor-based progress report and propagation automation system using the media such as MMS, VMS, EMS, FMS, SMS and web services of report and propagation. Based on this, the most effective u-Infrastructure Safety Management System is expected to be stably established at a less cost, thus making people's life more comfortable. Information obtained from such systems could be useful for maintenance or structural safety evaluation of existing structures, rapid evaluation of conditions of damaged structures after an earthquake, estimation of residual life of structures, repair and retrofitting of structures, maintenance, management or rehabilitation of historical structures.

  • PDF