• 제목/요약/키워드: Server Room

검색결과 79건 처리시간 0.029초

Mobile Guidance System for Evacuation based on Wi-Fi System and Node Architecture

  • Raju, Timalsina;Kim, Woo Sung
    • Journal of Information Technology Applications and Management
    • /
    • 제26권5호
    • /
    • pp.41-56
    • /
    • 2019
  • Recently great loss of life and property is occurring because of fire, natural disaster, earth quake, tsunami and so on. People spend 80~90% of their time indoor environment like office, supermarket, campus. Therefore Indoor navigation and guidelines system became so essential for most of all. Incase of emergency we must be careful earlier, in such a cases 5G kind of new technology may also cannot work. So immediate action and quick routing notification for guidelines and protection is the most. Considering this issue We proposed indoor evacuating guidance system based on microcontroller Wi-Fi board for Indoor APP using mobile. Focusing various kind of technology like, ok google, voice search APP we purposed node architecture based system. When we listen fire alarm while living inside the room. Then to be safe we connect with server and start Arduino UNO+IoT ESP8266 Wi-Fi shield version1-IoT module to store data in MySQL DB server. We make application to escape out from the building up-to the three exits giving information from source point to destination. Our program can send information to the users emergency location and situations. For this when the user get sound or vibration in their mobile device it indicate fire out near by. At that time we update message from Arduino to DB server for the fixed current position inside the building which give routing signal for that fire out location by changing values from 0 to 1. We have user in point 10 where user is near by. Later we detect Wi-Fi signal form Nodemcu as room of each floor and try to connect with user. Main purpose of this paper is to save life of people in short time and find out the shortest path up to nearest exits in the time of emergencies and rescue them.

데이터센터의 합리적인 환경제어를 위한 장비 발열기준에 대한 연구 (A Study on a Heat-load of IT Equipments for the Thermal Environment Control in the Data Center)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.938-943
    • /
    • 2006
  • The primary purpose of a computer room of data center and associated infrastructure is to support the operation of critical IT equipment. Traditionally, most owners of large critical data centers have been more than willing to accept a reasonable amount of computer room worker discomfort if necessary to support critical IT systems. All electrical equipment produces heat, which must be removed to prevent the equipment temperature from rising to an unacceptable level. Most information technology equipment and other equipment found in a data center or network room is air-cooled. Sizing a cooling system requires an understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by the other heat sources typically encountered.

  • PDF

고에너지물리를 위한 협업환경 도구와 KISTI EVO 서버 (Collaborative Tools in High Energy Physics and EVO Server at KISTI)

  • 김현우;조기현
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.234-237
    • /
    • 2007
  • We report on our experience on utilization of collaborative tools for KISTI high energy physics group. Our main subject will be the new EVO (Enabling Virtual Organization) server that we hosted recently at KISTI. The EVO is a next generation collaborative tool from CalTech high energy physics group with several improvements from its predecessor VRVS (Virtual Room Videoconferencing System). EVO has the same baseline structure as in VRVS. The network of servers lies at the heart of EVO structure and one server called Panda communicates with local clients called Koala.

  • PDF

데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구 (A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center)

  • 장현재
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

데이터센터에 적용된 외기도입 냉방시스템에서 필터유형별 에너지 소비량 변화 (Energy Consumption Analysis based on Filter Differential Pressure when Adopting an Air-side Economizer System for a Data Center)

  • 박성현;서장후;정용호;장현재;황석호
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.371-376
    • /
    • 2013
  • Recently, many studies related to reducing the energy consumption in data centers have been conducted. These studies have mainly focused on the air intake and exhaust system of a computer room air handling unit (CRAH) in the server room, diffuser type, suppression and discharge of the heat generated from the server, and the air-side economizer system. In this study, the energy consumption of the conventional central chilled water cooling system is compared with the energy consumption of the air-side economizer system. We also examined how changes of differential pressure by each filter have influenced energy consumption, using the power usage effectiveness (PUE). Results show that the PUE was improved, and energy consumption decreased, by applying the air-side economizer system.

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

파티션 시스템 적용을 통한 기존 데이터센터 서버실의 냉방 에너지 절감 성능평가 (Evaluation of Cooling Energy Saving through Applying Aisle Partition System on a Data Center Server Room)

  • 박종수
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.726-733
    • /
    • 2016
  • 본 연구에서는 기존 데이터센터 서버실에서 공기분배시스템으로 파티션 시스템의 적용성을 평가하기 위해 기존 시스템 그리고 파티션의 설치 높이와 위치를 변수로 하는 파티션 시스템과 컨테인먼트 시스템에 대해 총 21가지 경우의 컴퓨터시뮬레이션을 실시하고 다음과 같은 결론을 얻었다. 공기온도 및 기류 분포 해석결과를 이용하여 평가해 본 공기분배시스템별 냉방 에너지 절감 성능은 컨테인먼트 시스템, 파티션 시스템, 기존 시스템 순서로 우수한 것을 확인할 수 있었다. 기존 시스템과 파티션 설치높이 0.1~0.7m까지의 파티션 시스템은 재순환 공기에 의해 냉복도에서 1.0~1.2m 높이를 기점으로 공기 온도가 급격히 상승하면서 중간 높이의 서버와 상부 서버의 인입구 온도차는 $11{\sim}15^{\circ}C$로 큰 차이를 보여, 재순환 공기가 상부 서버의 과열의 원인을 제공하는 것으로 나타났다. 파티션 시스템에서 냉복도 상부에 파티션을 설치할 경우에 파티션의 적정 높이는 서버 랙 상부에서 천장까지 높이의 90%(0.9m)이상, 열복도 상부에 파티션을 설치하는 경우는 파티션 높이가 80%(0.8m)이상은 되어야 재순환 공기를 충분히 차단하여 서버 인입구 공기온도가 RCI 권장온도 범위를 만족하는 냉방 에너지 절감효과를 볼 수 있는 것으로 나타났다.

웹 기반의 감시제어시스템을 위한 임베디드 시스템 기술 (A Embedded System Technology for Web based monitoring and control system)

  • 박종진;최규석
    • 한국인터넷방송통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.61-66
    • /
    • 2009
  • 본 논문은 웹 기반의 감시제어시스템을 위한 임베디드 시스템 기술의 구현 예를 제시하였다. 웹 기반의 감시제어시스템을 위해 임베디드 시스템인 타겟 보드와의 인터페이스를 개발하고 이를 특정 임베디드 시스템인 온실 모델에 적용하여 그 실용성을 확인하였다. 자바 클래스를 이용한 클라이언트/서버 소켓 프로그램을 구현하였고, 자바 애플릿 기반의 사용자 인터페이스(GUI)에 의한 웹 기반 온실 감시제어시스템을 구축하였다. 구축된 웹 기반 감시제어시스템은 TCP/IP 상에서 온실의 정보를 클라이언트 프로그램에 잘 전달하여 표시하며 웹 상에서 동작하는 자바 애플릿 클라이언트에서 보내는 제어 신호를 서버를 통해 온실 모델에 잘 전달하여 동작시키는 것을 볼 수 있었다.

  • PDF

Thin Film Deposition of Antimony Tellurides for Ge-Sb-Te Compounds

  • Han, Byeol;Kim, Yu-Jin;Park, Jae-Min;Mayangsari, Tirta R.;Lee, Won-Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.330.1-330.1
    • /
    • 2014
  • 개인용 노트북, 태블릿 PC, 핸드폰 기술 발전에 의해 언제 어디서나 데이터를 작성하고 기록하는 일들이 가능해졌다. 특히 cloud 시스템을 이용하여 데이터를 휴대기기에 직접 저장하지 않고 server에 기록하는 일들이 가능해짐에 따라 server 기기의 성능, server-room power 및 space 에 대한 관심이 증가하였다. Storage class memory (SCM) 이란 memory device와 storage device의 장점을 결합한 memory를 일컫는 기술로 현재 소형 디바이스 부분부터 점차 그 영역을 넓히고 있다. 그중 phase change material을 이용한 phase change memory (PCM) 기술이 가장 각광받고 있다. PCM의 경우 scaling됨에 의해 cell간의 열 간섭으로 인한 data 손실의 우려가 있어 cell의 면적을 최소화 하여 소자를 제작하여야 한다. 기존의 sputtering등의 PVD 방법으로는 한계가 있어 ALD 공정을 이용한 PCM에 대한 연구가 활발히 진행중이다. 특히 tellurium 원료기체로 silyl 화합물 [1]을 사용하여 주로 $Ge_2Sb_2Te_5$의 조성에 초점을 맞춰 진행되고 있으나, 세부 공정에 대한 기본적인 연구는 미비하다. 본 연구에서는 Ge-Sb-Te 3원계 박막을 형성하기 위한 Sb-Te 화합물의 증착 공정에 대한 연구를 수행하였다. 특히 원료기체로 Si이 없는 새로운 Te 원료기체를 이용하여 조성 조절을 하였고, 박막의 물성을 분석하였다. 또한 공정온도에 따른 박막의 물성 변화를 분석하였다.

  • PDF

STOCHASTIC ORDERS IN RETRIAL QUEUES AND THEIR APPLICATIONS

  • 신양우
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2000년도 추계학술발표회 논문집
    • /
    • pp.105-108
    • /
    • 2000
  • We consider a Markovian retrial queue with waiting space in which the service rates and retrial rates depend on the number of customers in the service facility and in the orbit, respectively. Each arriving customer from outside or orbit decide either to enter the facility or to join the orbit in Bernoulli manner whose entering probability depend on the number of customers in the service facility. In this paper, a stochastic order relation between two bivariate processes (C(t), N(t)) representing the number of customers C(t) in the service facility and N(t) one in the orbit is deduced in terms of corresponding parameters by constructing the equivalent processes on a common probability space. Some applications of the results to the stochastic bounds of the multi-server retrial model are presented.