• 제목/요약/키워드: Series-parallel compensation

검색결과 36건 처리시간 0.026초

직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구 (A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter)

  • 오재훈;고수현;한윤석;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

Investigation of a SP/S Resonant Compensation Network Based IPT System with Optimized Circular Pads for Electric Vehicles

  • Ma, Chenglian;Ge, Shukun;Guo, Ying;Sun, Li;Liu, Chuang
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2359-2367
    • /
    • 2016
  • Inductive power transfer (IPT) systems have become increasingly popular in recharging electric vehicle (EV) batteries. This paper presents an investigation of a series parallel/series (SP/S) resonant compensation network based IPT system for EVs with further optimized circular pads (CPs). After the further optimization, the magnetic coupling coefficient and power transfer capacity of the CPs are significantly improved. In this system, based on a series compensation network on the secondary side, the constant output voltage, utilizing a simple yet effective control method (fixed-frequency control), is realized for the receiving terminal at a settled relative position under different load conditions. In addition, with a SP compensation network on the primary side, zero voltage switching (ZVS) of the inverter is universally achieved. Simulations and experiments have been implemented to validate the favorable applicability of the modified optimization of CPs and the proposed SP/S IPT system.

직병렬보상방법에 의한 초고압장거리송전선로의 보상효과분석 (The Effect Analysis of Series and Shunt Compensation Schemes for EHV Long Transmission Lines)

  • 정재길;강영묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.224-227
    • /
    • 1997
  • This study discuss two subjects : maximization of transmission capability and regulation of voltages along line within the permissible bounds. Series and parallel line compensation methods have been applied for those purposes using capacitors and reactors. In this paper, the effect of series and shunt line compensation for symmetrical line is analyzed. The results obtained in this paper can be applied 765kV class EHV transmission system.

  • PDF

전류 고조파와 불평형 전원 전압을 보상하는 직렬형 능동전력 필터와 병렬형 수동전력필터 병용시스템의 새로운 제어법 (A Novel Control Method of Combined System consists of Series Active Power Filter and Parallel Passive Power Filter to Compensate Current Harmonics and Unbalanced Source Voltages)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.615-623
    • /
    • 2001
  • In this paper, we study a series active power filter to compensate current harmonics and unbalanced source voltages. Conventional control methods for compensating unbalanced source voltages use source voltages to calculate compensation voltages, and in addition use load voltages to regulate load voltages. But the proposed control method uses load voltage to compensate unbalanced source voltages and regulate load voltages. And we propose a control method to reduce current harmonics which can calculate compensation voltages directly from source currents and load voltages. By well-matched operation of two control methods, the series active power filter can compensate current harmonics, unbalanced source voltages, and regulate load voltages. We compose a combined system of the series active power filter and parallel passive filters to confirm a validity of proposed control methods. The results from experiments are presented to demonstrate effectiveness of the proposed method.

  • PDF

순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation)

  • 한석우;최규하
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.544-551
    • /
    • 2000
  • In this paper, 3-phase hybrid series active power filter for compensate current harmonics, voltage drop and unbalanced voltage in the network presented. The proposed system is implemented with a space vector modulation voltage source inverter and a high pass filter connected in parallel to the power system. Here the load is six-pulses thyristor rectifier. The phase angle detected in order to generation reference voltage at load terminal is synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The proposed system has an function harmonic isolation between source and load, voltage regulation, and unbalance compensation. Therefore, what the power system is improved quality, the source current is maintained as a nearly sinusoidal waveform and the load voltage is regulated with a rated voltage regardless of the source variation condition. To verify the validity of the proposed compensating system, the computer simulation and experiment are carried out.

  • PDF

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

태양광 PV 어레이에서 병렬 부정합을 저감시키는 모듈 부정합 보상기법 (Method for PV Module Mismatch Compensation to Reduce Parallel Mismatch in Solar PV Array)

  • 박기엽;안희욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.170-171
    • /
    • 2010
  • The power loss due to PV module mismatch in PV array system is analyzed and a mismatch compensation method is proposed. A dc-dc converter is used to compensate for series mismatch caused by a low current module in a string. The converter is controlled to maximize the array power output. The proposed compensation method was verified by PSpice simulation.

  • PDF

실용적인 직병렬 구조의 무정전전원장치 (Practical Series-Parallel Compensated Uninterruptible Power Supply)

  • 전성즙;최규형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권6호
    • /
    • pp.322-329
    • /
    • 1999
  • In this paper a practical series-parallel compensated UPS is suggested, which has high input power factor and sinusoidal output voltage regulation capability. Compared to conventional cascaded UPS, the size can be reduced significantly with high quality input and output waveforms. The front converter and the main inverter can be considered decoupled, hence the front converter and the main inverter can be designed independent of each other. In this paper, analysis and experimental results for an l KVA prototype are presented.

  • PDF

무효전력 보상 용량 증대 및 DC 링크 전압 저감을 위한 SVC 결합형 UPQC (SVC coupled UPQC for reactive power compensation capacity increase and DC link voltage reduction)

  • 표수한;박장현;오정식;박태식
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.99-106
    • /
    • 2019
  • 본 논문에서는 UPQC 시스템과 SVC를 결합한 새로운 형태의 보상장치를 제안하고자 한다. 기존의 UPQC는 직렬형 인버터, 병렬형 인버터, DC 링크로 구성되어 있어있으며 우수한 전력품질 보상 성능을 보이지만 높은 인버터 정격을 요구한다. 제안된 방식은 직렬형 인버터, 병렬형 인버터와 DC 링크 그리고 병렬형 인버터의 출력단에 결합된 SVC로 구성되어 있으며, 기존 UPQC에 비해 넓은 무효전력 보상 범위와 낮은 DC 링크 전압의 장점을 가지고 있다. 또한, SVC가 결합된 새로운 UPQC의 구성은 Matlab 시뮬레이션을 통해 성능을 검증하였다.

비선형부하의 고조파전류 저감을 위한 직렬 및 병렬 동조필터에 관한 연구 (A Study on the Series and Parallel Resonant Filters for Harmonic Currents Reduction of Nonlinear Loads)

  • 김경철;강윤모;백승현;김종욱
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.113-118
    • /
    • 2003
  • 비선형 부하는 고조파 발생원으로 고조파 전압원과 고조파 전류원의 두종류로 분류된다. 직렬동조필터는 개인용 컴퓨터 부하와 같이 직류 캐패시터가 있는 비선형 부하로 고조파 전압원에 매우 효과적으로 고조파를 저감시킨다. 병렬동조필터는 교류 구동장치와 같이 직류 리액터가 있는 비선형 부하로 고조파 전류원에 적합하다. 본 논문에서는 직렬 및 병렬 동조 필터의 고조파 저감 특성과 비교를 검토하고 실험하였다. 국제 고조파 관리 기준인 IEC 1000-3-2 으로 직렬 및 병렬 동조필터의 고조파 저감 효과를 평가하고자 한다.