• 제목/요약/키워드: Series Connection Type

검색결과 108건 처리시간 0.024초

3차권선이 추가된 직렬연결형 초전도한류기의 전류제한 및 회복 특성 향상 (Improvement of Current Limiting and Recovery Characteristics in Series Connection Type SFCL with Added Third Winding)

  • 고석철;한태희;임성훈
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.62-68
    • /
    • 2014
  • The series connection type superconducting fault current limiter (SFCL) with added third winding, which was magnetically coupled in one iron core, was proposed. The proposed SFCL was expected to be more improved by just adding third winding into the conventional series connection type SFCL with two coils. To analyze the contribution of the third winding for the current limiting and the recovery characteristics of the SFCL, the short-circuit tests for the series connection type SFCL with the added third winding were performed together with the analysis on its electrical equivalent circuit. From the comparative analysis on the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising this SFCL, the improved current limiting and recovery characteristics of the series connection type SFCL using the third winding could be confirmed.

모의전력계통에 적용된 두 개의 자기결합 회로를 갖는 직렬연결형 초전도 전류제한기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of Series Connection-type SFCL with Two Magnetically Coupled Circuits Applied into a Simulated Power System)

  • 고석철;이신원
    • 한국전기전자재료학회논문지
    • /
    • 제26권1호
    • /
    • pp.68-72
    • /
    • 2013
  • The series connection-type superconducting fault current limiter (SFCL) with two magnetically coupled circuits was suggested and its effectiveness through the analysis on the current limiting and recovery characteristics was described. The fault current limiting characteristics of the proposed SFCL as well as the load voltage sag compensating characteristics according to the winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the series connection-type SFCL were carried out. The series connection-type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag compensating operations through the fast quench occurrence right after the fault appears and the fast recovery operation after the fault removes than that with the subtractive polarity winding.

Improvement of Current Limiting and Recovery Characteristics of Flux-Lock Type SFCL with Series Connection of Two Coils Using Its Third Coil

  • Ko, Seok-Cheol;Kim, Young-Pil;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.472-477
    • /
    • 2017
  • In this work, the current limiting and recovery characteristics of a flux-lock type superconducting fault current limiter (SFCL) with series connection of two coils were effectively improved by adding a third winding into the conventional flux-lock type SFCL with series connection of two coils. To confirm the contribution of the third winding to the current limiting and recovery characteristics of this type of the SFCL, short-circuit testing was carried out with consideration of the third winding, and the effect of the third winding on the current limiting and recovery characteristics was examined by comparative analysis of the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising the SFCL. Through the analysis of both the limiting impedance and the operational current as the main design parameter of the SFCL, the improved current limiting and recovery characteristics of the flux-lock type SFCL using the third winding could be verified.

감극 결선시 자속구속형 전류제한기의 퀜치 특성 (Quench Characteristics of Flux-lock Type SFCL in Subtractive Polarity Winding)

  • 황종선;한태희;최효상;박형민;조용선;남궁현;이나영;임성훈;정동철;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.251-252
    • /
    • 2006
  • As one of methods to increase the voltage rating of the flux-lock type SFCL, the fault current limiting characteristics of the flux-lock type SFCL with HTSC elements connected in series were analyzed. The initial fault current amplitudes in two SFCLs with the series connection of two HTSC elements and with single HTSC element were the same. In addition, the resistance amplitude of each HTSC element in SFCL with the series connection of two HTSC elements had the similar one in SFCL with single HTSC element. With increase of applying voltage, the unbalance of voltage between two HTSC elements in SFCL with the series connection of two HTSC elements disappeared.

  • PDF

직·병렬연결시 리액터를 이용한 초전도 소자의 퀜치 특성 (Quench Characteristics of Superconducting Elements using Reactors at Series and Parallel Connections)

  • 최효상;임성훈;조용선;남긍현;이나영;박형민
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.863-869
    • /
    • 2005
  • We investigated quench characteristics of superconducting elements connected in series and parallel each other. The serial and parallel connections of superconducting elements causes a difficulty in simultaneous quench due to slight difference between their critical current densities. In other to induce simultaneous quench, we fabricated four type circuits; serially connected circuit before parallel connection, the circuit connected in parallel before serial connection, serially connected circuit before parallel connection with reactors, the circuit connected in Parallel before serial connection with reactors. We confirmed that the simultaneous quenches occurred in serial and parallel connections of superconducting elements using reactors. In addition, the power burden of superconducting elements was smaller than those of serial and parallel connections of superconducting elements without reactors.

전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성 (Types of Misconceptions and their Consistencies of the Elementary School Teachers about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits)

  • 현동걸;신애경
    • 과학교육연구지
    • /
    • 제38권2호
    • /
    • pp.331-343
    • /
    • 2014
  • 전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성에 대하여 조사되었다. 초등교사들의 전지의 연결방법에 따른 전류의 특성에 대한 오개념은 3가지 유형으로 나타났다. 14명의 초등교사들을 대상으로 한 이 연구에서, 전지들의 직렬연결과 병렬연결시 전류의 특성을 연결하는 전지의 수에 초점을 맞추는 유형에는 2명의 초등교사가, 전지의 직렬연결에 대한 개념과 병렬연결에 대한 개념을 혼동하는 유형에는 8명의 초등교사가, 그리고 전지의 직렬연결과 병렬연결에 대한 개념을 저항의 직렬연결과 병렬연결에 대한 개념으로 혼동하는 유형에는 4명의 초등교사가 분포하였다. 초등교사들은 전지의 연결에 대한 학습개념이 적용되는 상황에서 뿐만 아니라 분화개념이 적용되어야 하는 상황에서도 그들의 오개념 유형을 일관성 있게 적용하고 있었다.

  • PDF

초전도 한류소자의 병렬연결에 따른 자속구속형 초전도 한류기의 특성 분석 (Characteristics of a Flux-Lock Type Superconducting Fault Current Limiter According to the Parallel Connection of the Superconducting Elements.)

  • 오금곤;정병익;최효상
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.198-201
    • /
    • 2008
  • We investigated the operating characteristics of the flux-lock type superconducting fault current limiter(SFCL) with the parallel connection between the primary and secondary windings which are connected with two superconducting units in series. The parallel connection for current level increase of the flux-lock type SFCL is necessary to apply the SFCL into the power system. The resistance generated in superconducting units was dependent upon the winding direction of the primary and the secondary coils, which can reduce the power burden. The resistance of the superconducting elements in the subtractive polarity winding is higher than that of the additive polarity winding. The fault current limiting effect of the subtractive polarity winding is better than that of the additive polarity winding. From this results, we confirmed that the power capacity of the flux-lock type SFCL could be increased by the parallel connection of the superconducting units.

자속구속형 초전도 사고전류 제한기의 직렬연결을 통한 동시 퀜치 특성 향상 (Improvement of Simultaneous Quench Characteristic of Flux-Lock Type Superconducting Fault Current Limiters Through Its Series Connection)

  • 임성훈
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.102-106
    • /
    • 2007
  • 본 논문에서는 자속구속형 초전도 사고전류제한기의 전압등급증대를 위한 방안으로 하나의 철심을 매개로 직렬로 연결된 자속구속형 초전도 사고전류제한기를 제안하고 이의 사고전류제한 특성을 분석하였다. 직렬 연결된 각각의 자속구속형 초전도 사고전류제한기의 구조는 두 개의 코일이 하나의 철심을 매개로 병렬로 연결되며 초전도 소자가 두 코일중 하나의 코일과 직렬로 연결된 구조를 가진다. 하나의 철심을 매개로 공유된 내부자속은 직렬연결된 각각의 자속구속형 초전도 사고전류제한기를 구성하는 초전도 소자들의 임계전류차이로 인한 불균일한 전력분담을 균일하게 유지시켜 주는 것을 실험을 통해 확인하였다.

3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석 (Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL)

  • 박형민;최효상;조용선;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.