• Title/Summary/Keyword: Series Arc

Search Result 211, Processing Time 0.028 seconds

Magamtism and Metamorphism of the Proterozoic in the Northeastern Part of Korea: Tectonomagmatic Characteristics of the Imgye Hornblendites (한국(韓國) 북동부지역(北東部地域) 원생대(原生代)의 화성활동(火成活動)과 변성작용(變成作用) : 임계(臨溪) 각섬암(角閃岩)의 암석성인(岩石成因)과 조구조적(造構造的) 특징(特徵))

  • Chang, Ho-Wan;Lee, Dong-Hwa
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.499-505
    • /
    • 1993
  • The Imgye hornblendites occur as intrusive sills or dykes within the mylonite zone developed along the contact boundary between Precambrian Jungbongsan granite and Cambrian Jangsan quartzite or Myobong slate formations. The hornlendites belong to the subalkaline and tholeiitic series. In tectonomagmatic discrimination diagrams such as $TiO_2-K_2O-P_2O_5$, 2Nb-Zr/4-Y and $TiO_2-10MnO-10P_2O_5$, the hornblendites are classified into continental- and island-arc tholeiites. The hornblendites show fractionated REE patterns with $(La/Yb)_{CN}$ ranging from 3.73-4.56. In incompatible element abundance variations, the hornblendites show distinctive positive and negative anomalies for Rb and Nb, respectively, and unfractionated patterns of immobile incompatible elements such as Y and Yb. The REE patterns of the hornblendites are also similar to those of typical continental back-arc tholeiites and those of the Precambrian Okbang amphibolites in the Socheon-meon, Bonghwa-gun. Accoiding to geochemical characteristics above-mentioned, the hornblendites seem to have been formed from tholeiitic magmas of depleted upper mantle source, contaminated by crustal material en route to continental back-arc basin.

  • PDF

SPECKLE OBSERVATION OF VISUAL DOUBLE STARS AT BOSSCHA OBSERVATORY: SEPARATION AND MAGNITUDE DIFFERENCE LIMITS

  • HADIPUTRAWAN, I PUTU WIRA;PUTRA, MAHASENA;IRFAN, MOCHAMAD;YUSUF, MUHAMMAD
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.223-224
    • /
    • 2015
  • We present the results of visual double stars speckle observations from 2013 using a Zeiss Double Refractor 60 cm with visual focal length f = 1,078 cm, and CCD SBIG ST-402 MEA. A Bessel V filter with ${\lambda}=550nm$ was placed in front of the CCD camera to reduce the chromatic aberration of the objective lens. The objects selected for this observation were calibration candidates and program stars with separations ranging from 0.9-6 arc second, and were located in both the northern and southern hemispheres. Seeing at Bosscha Observatory is generally 1-2 arc second, imposing a limit on visual double star separation below which the system cannot be resolved by long exposure imaging (longer than ~50 ms). Speckle interferometry methods are used to resolve double stars with separations below the typical size of seeing effects. A series of images were captured in fast short-time exposures (~50 ms) using a CCD camera. The result of our experiment shows that our system can be used to measure separations of 0.9 arc second (for systems with small ${\Delta}m$) and ${\Delta}m{\approx}3.7$ (for wide systems).

Frequency Spectrum Analysis of Corona Discharge Source Measured by Ultrasound Detector (초음파 감지기로 측정한 코로나 방전 소스의 주파수 스펙트럼 분석)

  • Cho, Hyun-Seob
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.78-82
    • /
    • 2019
  • This paper addressed the spectrum of ultrasonic waves produced by arc and/or coronal discharge inside the switchboard. Portable ultrasound sensors are useful for detecting discharge phenomena, such as coronal means in electrical systems. However, a typical handheld ultrasound detector has a disadvantage of determining the type of problem by listening to the sound characteristics and predicting the results, as a result of the determination of whether a discharge is present. Therefore, a new method of analysis is required to distinguish ultrasonic characteristics. In this paper, we published an ultrasound analysis case study to visualize the sound of ultrasonic waves measured with ultrasonic sensors. From the results of the experiment, it was possible to detect coronal discharge and serial arc discharge without interference by the ultrasonic detection system.

Elastica Solution of Large Deformation of Fiber Cantilever with Crimped Shapes (크림프를 가진 섬유 캔틸레버의 대변형의 일래스티카 해)

  • 정재호;강태진
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.102-105
    • /
    • 2001
  • In this paper, the solution of two dimensional deflection of circular wavy elastica beam was obtained for one end clamped boundary and concentrated load condition. The beam was regarded as a linear elastic material. Wavy shape was described as a combination of half-circular arc smoothly connected each other with constant curvature of all the same magnitude and alternative sign. Also load direction was taken into account. As a result, the solution was expressed in terms of a series of integral equations. While we found the exact solutions and expressed them in terms of elliptic integrals, the recursive ignition formulae about the displacement and arc length at each segment of circular section were obtained. Algorithm of determining unknown parameters was established and the profile curve of deflected beam was shown compared with initial shape.

  • PDF

Elliptic Integral Solutions of Large Deflection of Reinforcing Fiber Elastica with Circular Wavy Pattern

  • Jung, Jae-Ho;Lee, Kyung-Woo;Kang, Tae-Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.163-169
    • /
    • 2001
  • The solution of two-dimensional deflection of circular wavy reinforcing fiber elastics was obtained for one end clamped boundary under concentrated load condition. The fiber was regarded as a linear elastic material. Wavy shape was described as a combination of half-circular arc smoothly connected each other with constant curvature of all the same magnitude and alternative sign. Also load direction was taken into account. As a result, the solution was expressed in terms of a series of elliptic integrals. These elliptic integrals had two different transformed parameters involved with load value and initial radius of curvature. While we found the exact solutions and expressed them in terms of elliptic integrals, the recursive ignition formulae about the displacement and arc length at each segment of circular section were obtained. Algorithm of determining unknown parameters was established and the profile curve of deflected beam was shown in comparison with initial shape.

  • PDF

A Rectifier for DC Arc Holdings Having High Power Factor and Efficiency (고역율, 고효율 직류아아크용접기용 정류기)

  • Cho, Kyu-Min;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.385-388
    • /
    • 1994
  • This paper presents a new configure rectifier which has improved input power factor and efficiency for DC arc weldings. Two rectifiers are series connected and they are single-phase full-wave phase controlled rectifiers that use a transformer with two center-tapped secondary. The input power factor can be improved by controlling the each phase of rectifiers sequentially, and then the efficiency can be also improved because the reactive component currents will be reduced. It is confirmed that the proposed rectifiers has about 80% of input power factor and efficiency with the experimental results which are carried out at the output ranges of 100A to 300A.

  • PDF

Series Arc Wave Analysis and Detection Algorithm (직렬아크 파형 분석 및 검출 알고리즘)

  • Kwon, Wan-Sung;Choi, Su-Kyung;Bang, Sun-Bae;Kim, Chong-Min;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.240-242
    • /
    • 2009
  • 현재 미국에서는 전기화재를 예방하기 위한 AFCI(Arc Fault Circuit Interrupter) 설치가 법으로 제정되어 보급되고 있으며 이에 대한 기준인 UL1699가 제정되어 있다. 본 논문에서는 UL1699의 규정에 기반한 직렬아크발생장치를 통하여 여러 가정용 부하에서 발생시킨 아크의 전류파형들을 주파수영역과 이산 웨이블렛을 이용하여 분석해보고 그에 따른 검출 알고리즘을 제안하고자 한다.

  • PDF

A Study on Automatic Seam Tracking System Using Electro-Magnetic Sensor for Sheet Metal Arc Welding of Butt Joints (박판 맞대기 용접에서 전자기식 센서를 이용한 용접선 자동 추적 시스템에 관한 연구)

  • 유병희;김재웅
    • Journal of Welding and Joining
    • /
    • v.15 no.1
    • /
    • pp.81-91
    • /
    • 1997
  • In this study, a magnetic sensor to make use of eddy current was developed to detect the weld seam of butt joint in the sheet metal arc welding. This system consist of the sensor device for detecting the weld line, the servo control device for driving the weld torch movement and the control unit. A signal processing was applied to smooth the output signal of the sensor. The weld joint was determined by using a 1st order differential method. To improve tracking accuracy of the system, moving average method which has an effect of proportional and weighted integral control was applied to a series of the weld joint positions obtained above. The weld line for tracking was generated by using data regeneration algorithm. Based on these results, each servo motor was controlled by pulse generator. From experimental results, it was revealed that this system has excellent detecting ability for weld line and seam tracking ability.

  • PDF

Analysis of Series Arc Fault Current Using Discrete Wavelet Transform (이산 웨이블렛 변환을 이용한 직렬 아크고장전류 분석)

  • Bang, Sun-Bae;Kim, Chong-Min;Park, Chong-Yeun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.318-321
    • /
    • 2009
  • 누전차단기 설치 상태에서도 전기화재가 지속적으로 발생함에 따라 전기화재의 원인이 되는 전기 아크에 대한 관심이 증가하고 있는 실정으로 본 논문에서는 UL1699의 아크 저해시험(inhibition tests)에서 제시하고 있는 직렬 아크코장시험(Arc generator test)을 실시하고, 아크고장전류 분석방법으로 최근에 많이 사용되고 있는 이산 웨이블렛 변환을 이용한 3가지 분석방법에 대하여 아크고장전류 검출 확률을 분석하였다. 분석결과, (1) 근사계수 분석에 의한 최대치 변화율 실효치 변화율 분석방법은 46%의 검출 확률을 얻을 수 있었고, (2) 상세계수 분석에 의한 최대치 변화율 실효치 변화율 분석방법은 62%, (3) 근사계수 분석에 의한 잡음량 변화율 shoulder 변화율 분석방법은 100% 검출 확률을 얻을 수 있었다.

  • PDF

Soil Failure Mode of a Buried Pipe Around in Soil Undergoing Lateral Movement (측방변형지반속 매설관 주변지반의 파괴모드)

  • Hong, Won-Pyo;Han, Jung-Geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.5
    • /
    • pp.11-21
    • /
    • 2002
  • A series of model tests is performed to evaluate the relationship between soil and a buried pipe in soil undergoing lateral movement. As the result of the model tests, a wedge zone and plastic flow zones could be observed in front of the pipe. And also an arc failure of cylindrical cavity could be observed at both upper and lower zones. Failure shapes in both cohesionless and cohesive soils are nearly same, which was investigated failure angle of $45^{\circ}+{\phi}/2$. In the cohesionless soil, the higher relative density produces the larger arc of cylindrical cavity. On the basis of failure mode observed from model tests, the lateral earth pressure acting on a buried pipe in soil undergoing lateral movement could be applying the cylindrical cavity extension mode. The deformation behavior of soils was typically appeared in three divisions, which are elastic zones, plastic zones and pressure behavior zones.