• 제목/요약/키워드: Series 60

검색결과 1,039건 처리시간 0.031초

Preparation and Characteristics of Partially Fluorinated-Sulfonated Poly(biphenylene-co-sulfone)ether Membranes for Polymer Electrolyte Membrane Fuel Cell (고분자전해질 연료전지용 부분 불소계 설폰화 Poly(biphenylene-co-sulfone)ether 막의 제조와 특성)

  • Park, Jae-Wan;Chang, Bong-Jun;Kim, Jeong-Hoon;Lee, Yong-Taek
    • Polymer(Korea)
    • /
    • 제34권2호
    • /
    • pp.137-143
    • /
    • 2010
  • A series of partially fluorinated, sulfonated poly(biphenylene-co-sulfone)ether containing perfluorocyclobutane(PFCB) groups were prepared for fuel cell applications through three synthetic steps: synthesis of trifluorovinylether-terminated monomers, thermal cycloaddition and post-sulfonation. Two kinds of trifluorovinylether-terminated monomers were synthesized and statistically copolymerized via thermal cycloaddition to obtain a series of polymers containing 20-60 mol% of biphenyl units(PBS-X). The post-sulfonation of PBS-X was carried out using chlorosulfonic acid(CSA) to obtain copolymers with various sulfonation levels(SPBS-X). All the synthesized compounds, monomers and polymers were characterized by $^1H$-NMR, $^{19}F$-NMR and FT-IR. It was confirmed that the ion exchange capacity(IEC), water uptake and ion conductivity of SPBS-X increased with the increment of sulfonated biphenyl units. Particularly, SPBS-60 showed higher ion conductivity compared to Nafion$^{(R)}$-115 at 25~80 $^{\circ}C$.

Evaluation of the Output Dose of a Linear Accelerator Photon Beams by Using the Ionization Chamber TM31010 Series through TG-51 Protocol to Postal Monitoring Output of RPC for 5 Years (TM31010 계열의 공동이온전리함과 TG-51을 이용한 선형가속기광자선의 5년간 출력선량 평가)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • 제22권2호
    • /
    • pp.92-98
    • /
    • 2011
  • This study is to keep the accuracy and stability of the output dose evaluations for linear accelerator photon beams by using the air ionization chambers (TM31010, 0.125 cc, PTW) through the Task Group 51 protocol. The absorbed dose to water calibration factor $N_{dw}{^{Co-60}}$ was delivered from the air kerma calibration factor $N_k$ which was provided from manufacture through SSDL calibration for determination of output factor. The ionization chamber of TM31010 series was reviewed the calibration factor and other parameters for reduce the uncertainty within ${\pm}2%$ discrepancy and we found the supplied $N_{dw}{^{Co-60}}$ which was derived from Nk has shown a -2.8% uncertainty compare to that of PSDL. The authors provided the program to perform the output dosimetry with TG-51 protocol as it is composed same screen of TG-51 worksheets. The evaluated dose by determination of output factor delivered to postal TLD block for comparison the output dose to that of MDACC (RPC) in postal monitoring program. The results have shown the $1.001{\pm}0.013$ for 6 MV and $0.997{\pm}0.012$ discrepancy for 15 MV X rays for 5 years followed. This study shows the evaluated outputs for linear accelerate photon beams are very close to that of international output monitor with small discrepancy of ${\pm}1.3%$ with high reliability and showing the gradually stability after 2010.

A Study on Sequential-Frequency Sonication for Improving Anaerobic Digestion (혐기성 소화 효율 향상을 위한 초음파 주파수의 순차적 적용에 대한 연구)

  • Whang, Gye-Dae;Park, Sung-Han
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제25권6호
    • /
    • pp.893-906
    • /
    • 2011
  • The effect of ultrasound pretreatment on sludge degragability was investigated at different condotions: ultrasonic frequency(28, 40, 50kHz), intensity(10, 25, 50W), sonication time(10, 20, 30, 60min). Total suspended solid(TSS) and soluble chemical oxygen demand(SCOD) concentration were measured for the evaluation of pretreatment efficiency. The pretreated sludge was used as the feedstock for anaerobic digestion process. Biogas production and volatile suspended solid(VSS) removal were determined for evaluating the process performance. 1. TSS concentration of the sludge decreased at a constant rate as sonication operation was applied. The degradation rate of TSS increased when ultrasound frequency was decreased from 50kHz to 28kHz and intensity was increased from 10W to 50W. Efficiency of TSS degradation per input energy increased as ultrasonic frequency and intensity were decreased. At the frequency of 28 and 40kHz, SCOD concentration rapidly increased during the initial 30min of sonication time, and then it gradually increased. At 50kHz, SCOD concentration constantly increased for 60min of the sonication time. The SCOD production rate increased with increasing intensity under all ultrasound frequencies. 2. The optimum condition of ultrasound treatment was 28kHz, 50W and 60min for maximizing the biogas production, methane fraction, VSS removal. The highest values in biogas production, methane fraction in biogas, VSS removal were 370ml, 70%, 2.45g, respectively. Methane production rate per input energy increased at ultrasonic frequency and intensity decreased. 3. When raw sludge was pretreated at the condition of ultrasonic frequency of 28 and 40kHz in series, sequential-frequency sonication, intensity of 50W and 60min, biogas production, methane fraction, VSS removal were about the same that of 28kHz single-frequency sonication. When sequential-frequency sonication of 28 and 50kHz was applied in series, biogas production, methane fraction, VSS removal were 356 ~ 423ml, 69 ~ 71%, 2.41 ~ 2.78g, respectively. The pretreatment efficiency of 28-50kHz sequential-frequency sonication which sonication time of 28kHz and 50kHz was 40min and 20min was higher than that of 28kHz single-frequency sonication.

A Study on the Clarance Level for the Metal Waste from the KRR-1 & 2 Decommissioning (연구로 1,2호기 해체 금속폐기물의 규제해제농도기준(안) 도출을 위한 연구)

  • 홍상범;이봉재;정운수
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.660-664
    • /
    • 2003
  • The exposure dose form recycling on a large amount of the steel scrap from the KRR-1&2 decommissioning activities was evaluated, and also the clearance level was derived. The maximum individual dose and collective dose were evaluated by modifying internal dose conversion factor which was based on the concept of effective dose in ICRP 60, applied to the RESRAD-RECYCLE ver 3.06 computing code, IAEA Safety Series III-P-1.1 and NUREG-1640 as the assessment tool. The result of assessment for individual dose and collective dose is 23.9 ${\mu}Sv$ per year and 0.11 man$\cdot$Sv per year respectively. The clearance levels were ultimately determined by extracting the most conservative value form the results of the generic assessment and specific assessment methodologies. The result of clearance level for radionuclides($Co^60$, $Cs^137$) is less than $1.67{\times}10^{-1}$ Bq/g to comply with the clearance criterion(maximum individual dose : 10 $\muSv$ per year, collective dose : 1 man$\cdot$Sv per year) provided for Korea Atomic Energy Act and relevant regulations.

  • PDF

A Study on Hull-Form Design for Ships Operated at Two Speeds (두 가지 속도에서 운항하는 선박의 형상설계에 관한 연구)

  • Kim, Tae Hoon;Choi, Hee Jong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제24권4호
    • /
    • pp.467-474
    • /
    • 2018
  • The purpose of this study is related to automatic hull-form design for ships operating at two speeds. Research was conducted using a series 60 ($C_B=0.6$) ship as a target, which has the most basic ship hull-form. Hull-form development was pursued from the viewpoint of improving resistance performance. In particular, automatic hull-form design for a ship was performed to improve wave resistance, which is closely related to hull-forms. For this purpose, we developed automatic hull-form design software for ships by combining an optimization technique, resistance prediction technique and hull-form modification technique, appling the software developed to a target ship. A sequential quadratic programming method was used for optimization, and a potential-based panel method was used to predict resistance performance. A Gaussian-type modification function was developed and applied to change the ship hull-form. The software developed was used to design a target ship operating at two different speeds, and the performance of the resulting optimized hull was compared with the results of the original hull. In order to verify the validity of the program developed, experimental results obtained in model tests were compared with calculated values by numerical analysis.

A Study of Cleaning Technology for Zirconium Scrap Recycling in the Nuclear Industry (원자력산업에서 지르코늄 스크랩 재활용을 위한 세정기술에 관한 연구)

  • Lee, Ji-Eun;Cho, Nam-Chan;An, Chang-Mo;Noh, Jae-Soo;Moon, Jong-Han
    • Clean Technology
    • /
    • 제19권3호
    • /
    • pp.264-271
    • /
    • 2013
  • In this study, we optimized the removal condition of contaminants attached on the scrap surface to recycle the scrap generated from the Zr alloy tube manufacturing process back to the nuclear grade. The main contaminant is remnant of watersoluble cooling lubricant that is used in the pilgering manufacture during the tube production, and it is assumed to be compressed and carbonized on the surface of tube. Zirlo alloy tube of ${\phi}9.50mm$, which has high occurrence frequency of scrap, was selected as the object to be cleaned, and cleaning abilities of reagents were evaluated by measuring the characteristics of contaminants remained and by analyzing the surface of the tube after cleaning process. For evaluation of each cleaning agent, we selected two types of sodium hydroxide series and three types of potassium hydroxide series. Furthermore, to confirm dependence on tempe-rature and ultrasonic intensities, cleaning at the room temperature, $40^{\circ}C$, and $60^{\circ}C$ was conducted, and results showed that higher the cleaning temperature and higher the ultrasonic intensity, better the cleaning effect. As a result of the bare-eye inspection, while the use of sodium hydroxide provided satisfactory condition on the tube surface, the use of potassium hydroxide series provided satisfactory condition on the tube surface only when the ultrasonic intensity was over 120 W. In the cleaning effect analysis using the gravimetric method, cleaning efficiency of sodium hydroxide series was as high as 97.6% ($60^{\circ}C$, 120 W), but since the tube surface condition was poor after the use of potassium hydroxide, the gravimetric method was not appropriate. In the analytical result of surface contaminants on the tube surface, C, O, Ca, and Zr were detected, and mainly C and O dominated the proportion of contaminants. It was also found that the degree of cleaning on the tube affected the componential ratio of C and O; if the degree of cleaning is high, or if cleaning is well-conducted, the proportion of C is decreased, and the proportion of O is increased. Based on these results, optimal cleaning for application in the industry can be expected by categorizing cleaning process into three steps of Alkali cleaning, Rinsing, and Drying and by adjusting cleaning parameters in each step.

Effect of Gravity Perturbation on the Axis Specification in the Egg of Xenopus laevis (중력 작용의 변경 효과가 무미양서류 Xenopus laevis 수정란의 축형성에 미치는 영향)

  • 정해문;한평림
    • The Korean Journal of Zoology
    • /
    • 제27권3호
    • /
    • pp.127-136
    • /
    • 1984
  • The specification of dorsal/ventral axis in the egg of Xenopus laevis was investigated as a series of oblique orientation to gravity by tilt and clinostat. The results are as follows. (1) If the eggs were oriented, in the early period after fertilization, to novel gravity by $15^\\circ, 30^\\circ, 45^\\circ$ and $60^\\circ$ tilt until gastrula stage, the site of involution was usually formed in the OpG side (the side opposing gravity). As the degree of tilt was raised from $15^\\circ to 60^\\circ$, the rate of relocation of the involution site was proportionally increased. (2) When UV-irradiated eggs were tilted period to first cleavage by $15^\\circ, 30^\\circ, 45^\\circ$ and $6\^\\circ$, the effect of UV syndrome was rescued, and the extent of rescue was propotional to the tilt degree. (3) The fertile eggs were loaded on the clinostats of several speeds. In the range of low speeds between $0.45 \\sim 9.0$ rph, the location of dorsal lip was dependent on the direction of rotation, and in $40 \\sim 360$ rph, lip was formed at a random position. In addition, some of the tadpoles experienced with clinostat showed the typical syndrome of "dorsal axis reduction". The above results were discussed regarding the mechanism of the establishment of dorsal/ventral palarity. palarity.

  • PDF

Stress response of olive flounder, Paralichthys olivaceus and Japanese croaker, Nibea japonica on changes of water temperature

  • Hur, Jun Wook
    • Fisheries and Aquatic Sciences
    • /
    • 제25권8호
    • /
    • pp.441-449
    • /
    • 2022
  • In this study, we investigate the physiological response of olive flounder, Paralichthys olivaceus and Japanese croaker, Nibea japonica, on a series of rising water temperatures (WT). At 1, 9, and 17 days, WT increased from 23℃ (control) to 26, 29 and 32℃ within 6 hours, respectively, and then maintained for 96 hours. At 5, 13, and 21 days, WT decreased from each WT to 23℃ within 6 hours and was maintained at 23℃ for 96 hours. Blood were collected at 0, 1, 5, 9, 13, 17, 21, and 60 days. In both species, hematocrit, red blood cell and hemoglobin of stressed groups were lower than non-stressed group at 13 days. The osmolality of stressed group was lower than non-stressed group at 21 and 60 days. In olive flounder, hemoglobin of stressed groups was lower than non-stressed group at 21 and 60 days, respectively, but osmolality of stressed group was higher than non-stressed group at 9 days. In Japanese croaker, hematocrit, red blood cell and hemoglobin of stressed groups were higher than non-stressed group at 21 and 60 days, respectively, and osmolality of stressed group was higher than that of non-stressed group at 1 day. At 1, 17, and 21 days, aspartate aminotransferase (AST) and alanine aminotransferase (ALT) of stressed group were higher than non-stressed group in olive flounder. In Japanese croaker, AST and ALT of stressed group was lower than non-stressed group at 17, 21, and 60 days. The cortisol of olive flounder increased with increasing WT, but those of Japanese croaker increased with decreasing WT. In both species, the glucose increased with increasing WT. After changing WT, lactic acid of olive flounder and Japanese croaker were not significantly different. The physiological response of olive flounder increased directly to the increase in WT, and Japanese croaker contrasted with olive flounder.

Evaluation of Fatigue Strength by Graphite in Ductile Cast Iron (구상흑연주철재의 흑연에 의한 피로강도의 평가)

  • 이경모;윤명진;이종형
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제20권1호
    • /
    • pp.214-221
    • /
    • 2003
  • In this study, based on the effect of the interaction of fracture mechanics by graphite and fatigue limit phenomena of the microscopic observation various matrix structure, spheroidal ratio, size of graphite and distribution etc. parameters containd with Ductile Cast Iron. Therefore, in this study, different ferrite-pearlite matrix structure and spheroidal ratio of graphite of 70%, 80% and 90%, GCD40, GCD45-1 and GCD45-2 series and three different ferrite-pearlite matrix structure, GCD 45-3, GCD 50, GCD 60 series, all of which contain more than 90% spheroidal ratio of graphite, were used to obtain the correlation between mean size of spheroidal graphite and fatigue strength. (1) 73% pearlite structure had the highest fatigue limitation while 36% pearlite structure had the lowest fatigue limitation among ferrite-pearlite matrix. the increase in spheroidal ratio with increasing fatigue limitation, 90% had the highest, 14.3% increasing more then 10%, distribution range of fatigue life was small in same stress level. (2) (equation omitted) of graphite can be used to predict fatigue limit of Ductile Cast Iron. The Statistical distribution of extreme values of (equation omitted) may be used as a guideline for the control of inclusion size in the steelmaking processes.

The Design and Electrical Characteristics of 50kW Energy Storage System Using Hybrid Supercapacitor (하이브리드 슈퍼커패시터를 이용한 50kW급 에너지 저장 장치 설계 및 전기적 특성)

  • Mang, Ju-Cheul;Cho, Moon-Taek;Yoon, Jung-Rag
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제67권7호
    • /
    • pp.854-859
    • /
    • 2018
  • This paper describes the characteristics of a hybrid supercapacitor module for power quality stabilization. Hybrid supercapacitor is an promising energy storage device that positioned between conventional EDLC and Li-ion battery. A cylindrical 7500F hybrid supercapacitor ($60{\times}138mm$) was assembled by using the $Li_4Ti_5O_{12}$ electrode as an anode and activated carbon as a cathode. Considering the ESR and efficiency has been designed to module with 41.6F 480V design results in 180 series combination. In order to determine the characteristics of the hybrid supercapacitor module for power system, hybrid supercapacitor cells were connected in series with active balancing circuit. As a result of measuring the 50kw UPS, it was discharged at the current of 104A~143A during the discharge in the voltage range of 350V~480V, and the compensation time at discharge was measured to be about 30s. These results can be used to stabilization of power quality by applying hybrid supercapacitor module.