• Title/Summary/Keyword: Sepatic Tank

Search Result 1, Processing Time 0.019 seconds

An Improved Treatment of Animal Wastewater

  • Oh, I.H.;Kim, B.S.;Lee, S.R.;W.J.Maeng
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1379-1394
    • /
    • 1993
  • The purpose of this study is to examine the purification efficiency of the septic tank method which has been applied by the most of Korean livestock farms, in terms of anaerobic and aerobic treatment. Except several days in summer, BOD of effluent shows 1,500 -3,000 ppm by anaerobic process. In most cases , it exceeds according to the seasons show an increase by decrease of temperature. The removal effect on T-N is hardly found. The suspended solids contents of effluent are reduced to the level of 50-90%. Although BOD contents of effluent are kept high in the beginning, the removal rate of BOD shows 80 percent in the latter half by the aerobic treatment . The removal efficiency of total nitrogen does not appear through the experimental period, but the contents of T-N are not increased in the aerobic process unlike in the anaerobic process. The total phosphorous contents in effluent keep a constant level of 14 mg/L in average. The removal rate of phosphorous shows 91 percent i the last stage.