• Title/Summary/Keyword: Separation time

Search Result 1,798, Processing Time 0.03 seconds

The Effect of pH and Temperature on Lysozyme Separation in Ion-exchange Chromatography (이온교환크로마토그래피에서 라이소자임 분리에 미치는 pH와 온도 영향)

  • Ko, Kwan-Young;Kim, In-Ho
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.98-105
    • /
    • 2014
  • Lysozyme amounts to 0.3% in egg white and functions as an agent of cell lysis and activator of tissue reconstruction. Ion exchange chromatography is the most useful method of separation among affinity chromatography, ion exchange chromatography, and ultra-filtration. The aim of present study is to find the optimum pH and temperature for the separation of lysozyme in egg white within cation exchange gel filled glass column. And we compared results of experiments with those of simulations. Phosphate buffer was used, and pH and temperature were varied as 5~7 and $25{\sim}40^{\circ}C$ respectively. RP-HPLC was the tool for the retention time identification and quantitative analysis of lysozyme. OriginPro 8 measured the peak area of lysozyme chromatogram and quantified the eluted lysozyme. Largest amount of lysozyme was separated under the conditions of pH 5 and T $25^{\circ}C$.

Rapid separation and identification of 31 major saponins in Shizhu ginseng by ultra-high performance liquid chromatography-electron spray ionization-MS/MS

  • Sun, Ting-Ting;Liang, Xin-Lei;Zhu, He-Yun;Peng, Xu-Ling;Guo, Xing-Jie;Zhao, Long-Shan
    • Journal of Ginseng Research
    • /
    • v.40 no.3
    • /
    • pp.220-228
    • /
    • 2016
  • Background: Among the various ginseng strains, Shizhu ginseng is endemic to China, mainly distributed in Kuandian Manchu Autonomous County (Liaoning Province, China); however, not much is known about the compounds (especially saponins) in Shizhu ginseng. Methods: A rapid, sensitive, and reliable ultra-high performance liquid chromatography coupled with MS/MS (UHPLC-MS/MS) method was developed to separate and identify saponins in Shizhu ginseng. Results: The separation was carried out on a Waters ACQUITY UPLC BEH $C_{18}$ column ($100mm{\times}2.1mm$, $1.7{\mu}m$) with acetonitrile and 0.1% formic acid aqueous solution as the mobile phase under a gradient elution at $40^{\circ}C$. The detection was performed on a Micromass Quattro Micro API mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 31 saponins were identified or tentatively characterized by comparing retention time and MS data with related literatures and reference substances. Conclusion: The developed UHPLC-MS/MS method was suitable for identifying and characterizing the chemical constituents in Shizhu ginseng, which provided a helpful chemical basis for further research on Shizhu ginseng.

New Technologies for Enhancing Particles Separation Efficiency in Coagulation and Filtration (입자분리효율을 높이기 위한 새로운 기술)

  • Kunio, Ebie;Jang, Il-Hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.254-269
    • /
    • 2004
  • Polysilicato-iron coagulant (PSI) is receiving attention in Japan as a substitute for aluminum-based coagulants. In the first part of this article, coagulation, sedimentation and filtration experiments were carried out using kaolin clay particles as the turbidizing material and four types of PSI with various molar ratios of polysilicic acid to ferric chloride (Si/Fe ratio). Results demonstrate that use of a PSI with a high Si/Fe ratio can cause a more dramatic decrease in treated water turbidity but a higher suction time ratio (STR) than when PACl is used. However, optimization by increasing the rapid agitation strength GR is found to greatly improve the STR. In addition, the series of filtration experiments verified that optimization of GR is greatly effective in controlling rapid increases in filter head loss, and also formation of a thin aging layer in the upper part of the filter bed by slow-start filtration is effective in improving filtered water turbidity over the entire filtration process. The second part of this article describes two innovative filtration techniques to increase the particle separation efficiency; (1) coagulant-coated filter medium by enhancing the electrical potential of the surface of the filter medium, and (2) coagulant dosing in influent by controlling the electrical potential of particles entering the filter layer. From the results of the various filtration experiments using a pilot plant, these two techniques were found to be very effective to reduce the effluent water turbidity from the start to the end of a filter run. Moreover, in the filtration experiments using these two methods simultaneously, higher removal efficiency of approximately 3-log (99.7%) was realized, resulting that the finished water turbidity was accordingly reduced to 0.004mg/L.

Treatment of Aquacultural Recirculating Water by Foam Separation - II. Characteristics of Solid Removal - (포말 분리법을 이용한 양어장 순환수 처리 - II. 고형물 제거특징 -)

  • SUH Kuen-Hack;LEE Min-Gyu;LEE Min-Soo;KIM Byong-Jin;KIM Eun-Jung;CHO Moon-Chul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.334-339
    • /
    • 1997
  • The feasibility of foam separation to remove solid produced from fish culture water was investigated. Performance characteristics of foam separator were highly dependent upon the operating parameters which were superficial air velocity, Hydraulic retention time (HRT), and foam height. About $50\%$ of the total protein contained in a sample of fish culture water could be removed by foam separator. The removal efficiencies of protein, T-N, TA, and solid components were increased with increasing superficial air velocity and HRT. The combined effects of these operational variables show that removal rates of TVS increase with increasing superficial air velocity and HRT, and decrease as foam height goes up. It could be confirmed that foam separator might offer good perspective for removal of harmful components such as TA and TVS in aquacultural recirculating water.

  • PDF

Resourcing of Methane in the Biogas Using Membrane Process (분리막을 이용한 바이오가스의 메탄 자원화)

  • Park, Young G.;Yang, Youngsun
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.406-414
    • /
    • 2014
  • Biogas is a gaseous mixture produced from microbial digestion of organic materials in the absence of oxygen. Raw biogas, depending upon organic materials, digestion time and process conditions, contains about 45-75% methane, 30-50% carbon dioxide, 0.3% of hydrogen sulfide gas and fraction of water vapor. To achieve the standard composition of the biogas the treatment techniques like absorption or membrane separation was performed for the resourcing of biogas. In this paper the experimental results of the methane purification in simulated biogas mixture consisted of methane, carbon dioxide and hydrogen sulfide were presented. The composite membrane is manufactured within polysulfone in order to increase the separation performances for the gaseous mixtures of $CO_2$ and $CH_4$ which are main components of the biogas. The effects of feed pressures and mixed gas on the separation of $CO_2-CH_4$ by membrane are investigated. Chelate chemical was utilized to treat the purification of methane from the $H_2S$ concentration of 0.3%.

An Analysis of the Changes in Community Pharmacy Operation after the Implementation of the Separation Policy of Drug Prescription and Dispensing (의약분업 이후 약국의 운영현황 분석)

  • Ryu, See-Won;Youn, Kyung-Il;Chung, Woo-Jin
    • Korea Journal of Hospital Management
    • /
    • v.7 no.4
    • /
    • pp.102-122
    • /
    • 2002
  • It has been 2 years since the implementation of the separation policy of drug prescription and dispensing. This study analyzes the changes in community pharmacy operation after the implementation of the policy. The main purposes of the analysis are to determine whether the changes in community pharmacy operation have occurred and to evaluate that the changes are consistent with the intention of the policy, if the changes actually have occurred. For the study a survey on 961 pharmacies chosen by stratified sampling method has been performed. Of the 961 sample pharmacies, 438 pharmacies were responded resulting 45.6% response rate. The sample pharmacies are classified by the location that the pharmacy are operating: the pharmacies around large size hospitals, the pharmacies around clinics or medium to small size hospitals and the pharmacies with no hospitals or clinics around. Based on the classification, the number of pharmacies, number of prescriptions processed, the personnel structure, the changes in facility, and other operational characteristics are compared. The results showed that the pharmacies were tended to concentrate around hospitals and clinic since the implementation of the policy. The number of pharmacists per pharmacy was increased, the size of pharmacy was increased and the facilities were improved to accomodate the requirements of the policy. The work hours a pharmacist spent on dispensing drug have increased almost twice, however, there was no corresponding increase in the time spent on patient education and medication history management, indicating a problem in the provision of quality pharmaceutical services. Based on the results, suggestions to minimize the negative effects of the policy are provided.

  • PDF

Detection of Escherichia coli O157:H7 Using Combined Procedure of Immunomagnetic Separation and Test Strip Liposome Immunoassay

  • Kim, Myung-Hee;Oh, Se-Jong;Durst, Richard-A.
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.4
    • /
    • pp.509-516
    • /
    • 2003
  • A model system for the immnunochemical detection of Escherichia coli O157:H7 using a combined immunomagnetic separation (IMS) and test-strip liposome immunoassay (LIA) procedure was developed. Immunomagnetic beads coated with anti-E. coli O157 IgG antibodies were used to separate the E. coli O157 (including the H7 serotype) from culture. Immunoliposomes, whose surface was conjugated to goat anti-E. coli O157:H7 IgG and which encapsulated the marker dye, sulforhodamine B, were used as a detection label. The test strip, onto which antibodies to goat IgG were immobilized, was the immunosensor capturing immunoliposomes that did not bind to E. coli O157:H7 on the immunomagnetic bead-E. coli O157:H7 complexes. In experiments, pure cell culture suspensions of $10^5 E.$ coli O157:H7 organisms per ml produced a measurable signal inhibition, whereas a weak yet detectable signal inhibition occurred with $10^3CFU/ml$. The inhibition signals increased, when the incubation time for IMS was extended to 90 min and higher IgG-tag density (0.4mol%) was used on the liposomes. With 0.2 and 0.4mol% IgG-tagged liposomes, the IMS-LIA procedure showed more improved signal inhibitions than those of a direct (no IMS) LIA. The combined assay, which measures the instantaneous signal from immunoliposomes, can be completed within 90 min, making it significantly faster than conventional plating methods and enzyme-linked immunosorbent assay (ELISA). Accordingly, it is quite feasible to use the combined immunoassay format of IMS and dye-loaded immunoliposomes for the detection of E. coli O157:H7.

Determination of trace actinide (Am, Pu, Th, U) using alpha spectrometry and neutron activation analysis (알파분광법과 중성자방사화분석법에 의한 극미량의 악티늄계원소 (Am, Pu, Th, U)분석연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Kim, Yongjai;Lee, Myong Ho
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2004
  • Determination of actinides in the environmental sample requires separation of each element. This procedure is tedious and time consuming. And also, the detection limits of some nuclides using alpha spectrometry are rather higher. To overcome the lower detection limit and complicated separation procedure, a simple analytical technique for the determination of actinide isotopes in the environmental samples was developed and applied to IAEA and NIST reference sediment samples. For the separation of actinides from matrix, anion exchange resin and TRU-spec extraction chromatography resin were used and chemical yields were obtained using natural uranium, thorium, $^{242}Pu$ and $^{243}Am$ tracers. For overcoming the higher detection limits of U and Th in alpha spectrometry, neutron activation analysis was applied. Using combined method, the detection limit was increased about 10 times. The activity values of each isotope were consistent with the reference values reported by IAEA and NIST.

Study on Pressurized Diesel Reforming System for Polymer Electrolyte Membrane Fuel Cell in Underwater Environment (수중 환경에서 고분자 전해질 연료전지(PEMFC) 공급용 수소 생산을 위한 가압 디젤 개질시스템에 관한 연구)

  • Lee, Kwangho;Han, Gwangwoo;Bae, Joongmyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.528-535
    • /
    • 2017
  • Fuel cells have been spotlighted in the world for being highly efficient and environmentally friendly. A hydrogen which is the fuel of fuel cell can be obtained from a number of sources. Hydrogen source for operating the polymer electrolyte membrane fuel cell(PEMFC) in the current underwater environment, such as a submarine and unmanned underwater vehicles are currently from the metal hydride cylinder. However, metal hydride has many limitations for using hydrogen carrier, such as large volume, long charging time, limited storage capacity. To solve these problems, we suggest diesel reformer for hydrogen supply source. Diesel fuel has many advantages, such as high hydrogen storage density, easy to transport and also well-infra structure. However, conventional diesel reforming system for PEMFC requires a large volume and complex CO removal system for lowering the CO level to less than 10 ppm. In addition, because the preferential oxidation(PROX) reaction is the strong exothermic reaction, cooling load is required. By changing this PROX reactor to hydrogen separation membrane, the problem from PROX reactor can be solved. This is because hydrogen separation membranes are small and permeable to pure hydrogen. In this study, we conducted the pressurized diesel reforming and water-gas shift reaction experiment for the hydrogen separation membrane application. Then, the hydrogen permeation experiments were performed using a Pd alloy membrane for the reformate gas.

Solvent Resistance and Gas Permeation Property of PEI-PDMS Hollow Fiber Composite Membrane for Separation and Recovery of VOCs (VOCs의 분리 및 회수를 위한 PEI-PDMS 중공사 복합막의 내용매성 및 기체 투과 특성)

  • Kim, Se-Jong;Lee, Chung-Seop;Koh, Hyung-Chul;Ha, Seong-Yong;Nam, Sang-Yong;Rhim, Ji-Won;Choi, Whee-Moon
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • To separate and recover of VOCs, supporting membranes using PEI were prepared by phase separation method and it was coated with PDMS to prepare PEI-PDMS hollow composite membrane. To investigate characteristic of prepared membrane, pure gas permeability was measured using oxygen and nitrogen, the stage cut and permeance property with feed concentration were evaluated using xylene, ethyl benzene, toluene and cyclohexane. Also, to check solvent resistance on VOCs, stress-strain property of membrane with immersion time in solvent were measured by DMA. The permeance value of $O_2$ and $N_2$ showed 63 GPU and 30 GPU respectively. Permeated VOCs concentration was decreased with increasing stage cut. But, conversely, recovery efficiency that was increased with increasing stage cut. As a result of DMA test, the stress and strain were 11.93 MPa and 13.52%, respectively.