• Title/Summary/Keyword: Separation technology

Search Result 3,005, Processing Time 0.028 seconds

Magnetic Force Control Technique for Recycling and Environmental Preservation

  • Nishijima, Shigheiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.1-4
    • /
    • 2012
  • The applicability of the two types of magnetic separation system, high gradient magnetic separation (HGMS) and Magneto Archimedes method were studied considering the magnetic susceptibility of targeted substances. It was noted that the combination of the two methods can control the almost all the substances, paramagnetic and diamagnetic in addition to ferromagnetic substances. The principle of the methods was given and the conceput of the magnet force control technology is discussed. The practical applications of the technique were introduced together with the new application of HGMS.

The synergistic solvent extraction effect of europium and yttrium using the hexanoic acid -crown ether system (Hexanoic acid - crown ether system을 이용한 europium과 yttrium의 용매추출효과의 향상)

  • Sim, Dea-Seon;Han, Hye-Rim;Kim, Se-Mi;Kim, Jeong-Hoon;Kim, Young-Wun;Jeong, Noh-Hee;Kang, Ho-Cheol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.31-39
    • /
    • 2015
  • The synergistic solvent extraction of rare earth elements such as europium and yttrium has been investigated by the extractant with crown ether as an additive. Macrocyclic ligand as host-guest compounds form more stable complexes with metal ions which have the similar size of the cavity of crown ether. In our previous study[14] founded that the extraction used fatty acid of the various alkyl chain length. Based on the results of the previous experiment, the synergistic separation effect of two metals investigated that the hexanoic acid had was the worst extraction effect which added a crown ether such as 18-crown-6 ether, 15-crown-5 ether, and 12-crown-4 ether. In this study, the concentrations of hexanoic acid have showed the separation effect, and then the concentrations and kind of crown ether are performed for synergistic extraction at the hexanoic acid concentration of the highest separation effect. As a results, the separation rate is the highest value of 1.72 at 0.05 M hexanoic acid, and 0.002M 15-crown-5 ether is the best value in other concentrations and kind of crown ether, it is about twice of using only hexanoic acid. Moreover, the extraction species of two metals has been founded $MLR_3{\cdot}3RH$ form when added the crown ether.

Gas Separation Study of PEBAX 3533 and PEG Blended Membranes (PEBAX 3533과 PEG의 혼합막에 대한 기체투과 연구)

  • Kim, Kwang Bae;Cho, Eun Hye;Cheong, Seong Ihl;Lee, Hyung Keun;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.144-150
    • /
    • 2013
  • In order to increase the permeabilities of $N_2$, $O_2$, $CH_4$, $CO_2$, $SO_2$, Poly (ether block amides) (PEBAX) 3533 and its blended membranes with Poly (ethylene glycol) (PEG) of molecular weight 400 were prepared. The contents of PEG400 were 20%, 40%, and 50% and this membranes were characterized in terms of permeability for $N_2$, $O_2$, $CH_4$, $CO_2$, $SO_2$ gases and also diffusivity and solubility as well by using the time-lag gas separation apparatus. As expected, the permeabilities incerased as the contents of PEG400 increased. For the ideal selectivity, there is no big difference in values of between PEBAX 3533 and PEBAX/PEG400 membranes. The increase of permeabilities is due to the increases of solubilities of gases in question and this will be explained in more detail.

A Study on Flow Rate Properties and Optimal Selection of Nitrogen Membrane Module of Hollow Fiber Type (중공사형 질소 분리막 모듈의 최적 선정과 유량특성에 관한 연구)

  • Kim, Jong-Do;Lee, Sangu-Su;Kim, Jeon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.915-922
    • /
    • 2008
  • The gas separation technology using membrane is widely used to refine various gases in many industry fields and recently is being applying in $CO_2$ recovery technology. In the gas and chemical tanker. nitrogen generators for inerting, purging and padding are on board and most of them have membrane modules of hollow fiber type with long life and vibration resisting properties. Because a membrane module is a key component accounting for 50% of total manufacturing cost of nitrogen generator, adequate selection for it is an important problem. In this paper, the flow performance coefficient based on dimension and specification data of membrane module was relatively selected to compare nitrogen generating capacity of module and various performance tests about the selected PARKER ST6010 membrane module were conducted. As a result, the useful coefficient and basic data in selecting a membrane module were achieved.

Analysis of Solid Oxide Fuel Cell/Oxy-fuel Combustion Power Generation System Using Oxygen Separation Technology (산소분리기술을 사용한 연료전지/순산소연소 발전시스템 해석)

  • Park, Sung-Ku;Kim, Tong-Seop;Sohn, Jeong-Lak;Lee, Young-Duk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.51-54
    • /
    • 2008
  • This study aims to devise and analyze a power generation system combining the solid oxide fuel cell and oxy-fuel combustion technology. The fuel cell operates at an elevated pressure, a constituting a SOFC/gas turbine hybrid system. Oxygen is extracted from the high pressure cathode exit gas using ion transport membrane technology and supplied to the oxy-fuel power system. The entire system generates much more power than the fuel cell only system due to increased fuel cell voltage and power addition from oxy-fuel system. More than one third of the power comes out of the oxy-fuel system. The system efficiency is also higher than that of the fuel cell only system. Recovering most of the generated carbon dioxide is major advantage of the system.

  • PDF

Performance Evaluation of Hinge Driving Separation Nut-type Holding and Releasing Mechanism Triggered by Nichrome Burn Wire

  • LEE, Myeong-Jae;LEE, Yong-Keun;OH, Hyun-Ung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.4
    • /
    • pp.602-613
    • /
    • 2015
  • As one of the mission payloads to be verified through the cube satellite mission of Cube Laboratory for Space Technology Experimental Project (STEP Cube Lab), we developed a hinge driving separation nut-type holding and releasing mechanism. The mechanism offers advantages, such as a large holding capacity and negligible induced shock, although its activation principle is based on a nylon cable cutting mechanism triggered by a nichrome burn wire generally used for cube satellite applications for the purpose of holding and releasing onboard appendages owing to its simplicity and low cost. The basic characteristics of the mechanism have been measured through a release function test, static load test under qualification temperature limits, and shock measurement test. In addition, the structural safety and operational functionality of the mechanism module under launch and on-orbit environments have been successfully demonstrated through a vibration test and thermal vacuum test.

Edge Router Selection and Traffic Engineering in LISP-Capable Networks

  • Li, Ke;Wang, Sheng;Wang, Xiong
    • Journal of Communications and Networks
    • /
    • v.13 no.6
    • /
    • pp.612-620
    • /
    • 2011
  • Recently, one of the problems with the Internet is the issue of scalability. To this end, locator/identifier separation protocol (LISP), which separates end-system identifiers and routing locators, has been proposed as a solution. In the LISP deployed network, the ingress and egress nodes of inter-AS traffic is determined by edge router selection (ERS) and endpoint identifier-routing locator mapping assignment (ERMA). In this paper, joint optimizations of ERS and ERMA for stub networks with and without predetermined link weights are studied and the mixed integer linear programming (MILP) formulations for the problems are given. To make the problem with optimizable link weights tractable, a revised local search algorithm is also proposed. Simulation results show that joint optimization of ERS and ERMA enables better network performance.

Selection of Key Radionuclides for P&T Based on Radiological Impact Assessment for the Deep Geological Disposal of Spent PWR/CANDU/DUPIC Fuels

  • Lee, Dong-Won;Chung, Chang-Hyun;Kim, Chang-Lak;Park, Joo-Wan
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.231-240
    • /
    • 2001
  • When it is assumed that PWR, CANDU and DUPIC spent fuels are disposed of in deep geological repository, consequent annual individual doses are calculated, and it is shown that doses meet the regulatory limit. From these results, the hazardous radionuclides applicable to partitioning and transmutation are selected. These selected radionuclides such as Tc-99, Ⅰ-129, Cs-135 and Np-237 are then reviewed in terms of partitioning and transmutation. Separation of I-129, Np-237 and Tc-99 from spent fuels is considered desirable, and transmutation of these radionuclides results in remarkable hazard reduction. However, it is concluded that separation and transmutation of Cs-135 may be ineffective although it is classified into a hazardous radionuclide.

  • PDF

Synthesis and Microphase Separation of Biodegradable Poly($\varepsilon$-caprolactone)-Poly(ethylene glycol)-Poly($\varepsilon$-caprolactone) Multiblock Copolymer Films

  • You, Jae-Ho;Choi, Sung-Wook;Kim, Jung-Hyun;Kwak, Young-Tae
    • Macromolecular Research
    • /
    • v.16 no.7
    • /
    • pp.609-613
    • /
    • 2008
  • Poly($\varepsilon$-caprolactone)-poly(ethylene glycol)-poly($\varepsilon$-caprolactone) (PCL-PEG-PCL) multiblock copolymers at various hydrophobic-hydrophilic ratios were successfully synthesized by the chain extension of triblock copolymers through isocyanate (hexamethylene diisocyanate). Biodegradable films were prepared from the resulting multiblock copolymers using the casting method. The mechanical properties of the films were improved by chain extension of the triblock copolymers, whereas the films prepared by the triblock copolymers were weak and brittle. Atomic force microscopy (AFM) of the multiblock copolymer film showed that the hydrophilic PEG had segregated on the film surface. This is consistent with the observed contact angle of the films.

MEMBRANE FORLING MECHANIMS IN MEMBRANE-COUPLES ANAEROBIC BIOREACTOR

  • Choo, Kwang-Ho;Lee, Chung-Hak
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.04a
    • /
    • pp.41-41
    • /
    • 1993
  • Recently, the advanced membrane separation technology has even been applied to the post treatment to biological process of wastewater treatment, since the efficiency of biological treatment significantly depends on maintaining a high biomass concentration in the bioreator. Particularly, anaerobic microbes in the biological system have slower growth rates than aerobic microbes and thus it takes a long hydaulic retention time(HRT) to prevent biomass washout in the completely mixed anaerobic digester. The anaerobic sludge also has poor settleability owing to its diffusible and somewhat filamentous nature. Moreover, the residual gasification and consequent sludge rise in the clarifier compartment become a considerable problem, which proves that complete separation of biological solids is difficult.

  • PDF