• 제목/요약/키워드: Separation ratio

검색결과 1,111건 처리시간 0.029초

다분류 SVM을 이용한 DEA기반 벤처기업 효율성등급 예측모형 (The Prediction of DEA based Efficiency Rating for Venture Business Using Multi-class SVM)

  • 박지영;홍태호
    • Asia pacific journal of information systems
    • /
    • 제19권2호
    • /
    • pp.139-155
    • /
    • 2009
  • For the last few decades, many studies have tried to explore and unveil venture companies' success factors and unique features in order to identify the sources of such companies' competitive advantages over their rivals. Such venture companies have shown tendency to give high returns for investors generally making the best use of information technology. For this reason, many venture companies are keen on attracting avid investors' attention. Investors generally make their investment decisions by carefully examining the evaluation criteria of the alternatives. To them, credit rating information provided by international rating agencies, such as Standard and Poor's, Moody's and Fitch is crucial source as to such pivotal concerns as companies stability, growth, and risk status. But these types of information are generated only for the companies issuing corporate bonds, not venture companies. Therefore, this study proposes a method for evaluating venture businesses by presenting our recent empirical results using financial data of Korean venture companies listed on KOSDAQ in Korea exchange. In addition, this paper used multi-class SVM for the prediction of DEA-based efficiency rating for venture businesses, which was derived from our proposed method. Our approach sheds light on ways to locate efficient companies generating high level of profits. Above all, in determining effective ways to evaluate a venture firm's efficiency, it is important to understand the major contributing factors of such efficiency. Therefore, this paper is constructed on the basis of following two ideas to classify which companies are more efficient venture companies: i) making DEA based multi-class rating for sample companies and ii) developing multi-class SVM-based efficiency prediction model for classifying all companies. First, the Data Envelopment Analysis(DEA) is a non-parametric multiple input-output efficiency technique that measures the relative efficiency of decision making units(DMUs) using a linear programming based model. It is non-parametric because it requires no assumption on the shape or parameters of the underlying production function. DEA has been already widely applied for evaluating the relative efficiency of DMUs. Recently, a number of DEA based studies have evaluated the efficiency of various types of companies, such as internet companies and venture companies. It has been also applied to corporate credit ratings. In this study we utilized DEA for sorting venture companies by efficiency based ratings. The Support Vector Machine(SVM), on the other hand, is a popular technique for solving data classification problems. In this paper, we employed SVM to classify the efficiency ratings in IT venture companies according to the results of DEA. The SVM method was first developed by Vapnik (1995). As one of many machine learning techniques, SVM is based on a statistical theory. Thus far, the method has shown good performances especially in generalizing capacity in classification tasks, resulting in numerous applications in many areas of business, SVM is basically the algorithm that finds the maximum margin hyperplane, which is the maximum separation between classes. According to this method, support vectors are the closest to the maximum margin hyperplane. If it is impossible to classify, we can use the kernel function. In the case of nonlinear class boundaries, we can transform the inputs into a high-dimensional feature space, This is the original input space and is mapped into a high-dimensional dot-product space. Many studies applied SVM to the prediction of bankruptcy, the forecast a financial time series, and the problem of estimating credit rating, In this study we employed SVM for developing data mining-based efficiency prediction model. We used the Gaussian radial function as a kernel function of SVM. In multi-class SVM, we adopted one-against-one approach between binary classification method and two all-together methods, proposed by Weston and Watkins(1999) and Crammer and Singer(2000), respectively. In this research, we used corporate information of 154 companies listed on KOSDAQ market in Korea exchange. We obtained companies' financial information of 2005 from the KIS(Korea Information Service, Inc.). Using this data, we made multi-class rating with DEA efficiency and built multi-class prediction model based data mining. Among three manners of multi-classification, the hit ratio of the Weston and Watkins method is the best in the test data set. In multi classification problems as efficiency ratings of venture business, it is very useful for investors to know the class with errors, one class difference, when it is difficult to find out the accurate class in the actual market. So we presented accuracy results within 1-class errors, and the Weston and Watkins method showed 85.7% accuracy in our test samples. We conclude that the DEA based multi-class approach in venture business generates more information than the binary classification problem, notwithstanding its efficiency level. We believe this model can help investors in decision making as it provides a reliably tool to evaluate venture companies in the financial domain. For the future research, we perceive the need to enhance such areas as the variable selection process, the parameter selection of kernel function, the generalization, and the sample size of multi-class.

왕겨/모래/왕겨 회재의 유동 및 혼합 특성 연구 (Flow Behavior and Mixing Characteristics of Rice Husk/Silica Sand/Rice Husk Ash)

  • 김보화;서명원;국진우;최희망;라호원;윤상준;문태영;김용구;이재구;이영우
    • Korean Chemical Engineering Research
    • /
    • 제54권4호
    • /
    • pp.533-542
    • /
    • 2016
  • Lab-scale 기포유동층 반응기(D=0.1 m, H=1.5 m)에서 왕겨와 모래를 혼합하여 가스화를 통해 합성가스를 얻고 남은 왕겨 회재는 고부가가치 물질로 사용하기 위한 연구의 선행연구로서 왕겨/유동사/왕겨 회재(실리카)의 혼합 및 유동 특성을 규명하였다. 왕겨/유동사를 5:95, 10:90, 20:80, 30:70의 부피비로 유속 범위(0~0.63 m/s)조건으로 수행하였으며, 또한 왕겨 회재는 왕겨를 기준으로 부피비 6%로 결정하였다. 왕겨/유동사, 왕겨/유동사/왕겨 회재의 혼합실험을 통해 왕겨 부피비 0%, 5%, 10%에서는 최소유동화속도가 0.19~0.21m/s임을 확인하였고, 20%일때는 0.3m/s로 증가하였으며, 30%일때는 분리현상이 나타나 최소유동화속도가 측정 되지 않았다. 또한, 실험데이터에 따라 Brereton과 Grace의 mixing index를 이용하여 각 조건 별로 mixing index값을 도출한 결과 왕겨/유동사의 혼합은 0.8~1, 왕겨/유동사/왕겨 회재의 혼합은 0.88~1 사이임을 확인하였다. 이를 통하여 왕겨/유동사의 혼합과 왕겨/유동사/왕겨 회재 혼합의 최적 조업조건을 도출할 수 있었으며, 운전조건을 결정할 수 있었다.

간 이식편의 체적 예측을 위한 2점 이용 간 분리 (Liver Splitting Using 2 Points for Liver Graft Volumetry)

  • 서정주;박종원
    • 정보처리학회논문지B
    • /
    • 제19B권2호
    • /
    • pp.123-126
    • /
    • 2012
  • 본 논문은 생체간이식 전에 복부 MDCT(Multi-Detector Computed Tomography) 영상에서 간 이식편의 체적을 간단하고 정확하게 계산하기 위하여 좌간과 우간을 나누는 방법을 제안하였다. 본 알고리즘은 기증자와 수혜자의 안전을 보장하기 위하여 시스템과 의료진의 상호작업을 최소화 하여 의료진이 수술 전 이식편의 판단을 정확하게 처리할 수 있도록 하였다. 간이 추출된 영상에 좌간과 우간을 나눌 수 있는 2점(중간 정맥(MHV: Middle Hepatic Vein) 내부의 한 점과 좌우문맥(PV: Portal Vein) 분지부에서 한 점)을 선택한다. 선택된 중간정맥 내부의 점을 이용하여 중간정맥을 자동 인식한 후 중간정맥을 기준으로 절개선을 결정하여 문맥 분지부의 한 점을 연결하는 절개면을 형성한다. 좌간과 우간의 체적과 간 전체에 대한 좌우간의 비율을 계산한다. 계산된 체적의 정확성을 입증하기 위해 진단 방사선과 의사가 수동으로 처리하여 계산한 체적과 함께 수술 중 획득한 실측무게와 비교하였다. 실측무게와 수동으로 예측된 체적 사이의 오차에 대한 평균${\pm}$표준편차는 $162.38cm^3{\pm}124.39$이고, 실측무게와 2점을 이용하여 예측된 체적과의 오차에 대한 평균${\pm}$표준편차는 $107.69cm^3{\pm}97.24$이다. 실측무게와 수동으로 예측된 체적의 상관관계는 0.79이고, 실측무게와 2점을 이용하여 예측된 체적의 상관관계는 0.87이다. 그리고 2점을 선택한 후 좌우간을 분할하여 체적을 계산하는 시간을 측정하여 수술실에서 실시간으로 처리 가능한지의 여부를 확인하였다. 한 데이터세트($149.17pages{\pm}55.92$) 당 처리 시간의 평균${\pm}$표준편차는 $57.28sec{\pm}32.81$이다.

가공조건이 Pork Cutlet의 물리적 및 관능적 특성에 미치는 영향 (Effect of Processing Conditions on the Physical and Sensory Characteristics of Pork Cutlets)

  • 김일석;민중석;이상옥;장애라;김동훈;진상근;이무하
    • 한국축산식품학회지
    • /
    • 제24권4호
    • /
    • pp.319-325
    • /
    • 2004
  • 본 연구는 국내산 냉동 및 냉장 등심의 가공조건을 달리하여 Pork cutlet를 제조하고 물리적 및 관능적 품질 특성을 비교하여 국내에서 비선호 부위인 냉동 등심의 외식용으로서의 소비 확대를 꾀하고자 수행되었다. Pork cutlet원료용 돼지고기 등심은 냉장육(T1), 염지 및 마사징처리 냉장육(T2), 염지 및 마사징처리 냉동육(T3), 냉동육(T4), 마사징처리 냉동육(T5)으로 처리조건을 달리한 후 Pork cutlet를 제조하여 물리적 및 관능적 품질특성을 평가하였다. 보수력 측정 결과, 모든 처리구간에 유의적인 차이는 없었다. 냉장육인 경우에, 염지와 마사징 처 리(T2)가 무처리구(T2)에 비해 다소 높게 나타났다. 처리구간 T4가 가장 낮은 보수력을 나타내었다. 육색 측정 결과 냉장육의 경우 처리구간 L$^{*}$ 값, a$^{*}$ 값 및 b$^{*}$ 값 모두 유의적인 차이가 없었다. 냉동육인 경우 L$^{*}$ 값은 T3 및 T5 처리구가 T4 처리구보다 높았고, b$^{*}$ 값은 T5 처리구가 유의적으로 높게 나타났으나(p<0.001), a$^{*}$ 값은 모든 처리구간에서 유의적인 차이가 없었다. 냉동육을 염지와 맛사징한 등심을 이용하여 제조한 T3 처리구의 Pork cutlet이 가장 낮은 전단력을 보여 상대적으로 가장 연도가 우수하였고(p<0.001), 무처리된 냉동육을 이용한 T4 처리구의 Pork cutlet이 가장 높게 나타났다. 밀가루 반죽과 고기 표면과 분리율은 T4처리구에서 유의적으로 높게 나타났다(p<0.001). 식별강도는 T1 : T3조합에서 가장 높게 나타났고, 척도묘사분석의 결과 전체적인 기호도는 유의적으로 가장 낮게 평가된 T4 처리구를 제외한 전 처리구간에서의 유의적인 차이가 없었다. 이상의 결과에서 냉동육만으로 pork cutlet를 제조하면 냉장육으로 제조한 pork cutlet와 물리적 및 관능적 특성에서 큰 차이를 보이므로 냉동육을 염지하거나 맛사징 처리하여 pork cutlet를 제조하면 냉동 돈육 등심의 소비 촉진에 기여할 수 있다고 판단되었다.

미국(美國) 내셔널브랜드 C사(社)의 마케팅전략(戰略)을 통한 브랜드리뉴얼 성공사례(成功事例) 연구(硏究) (A Study on the Successful Case of Brand Renewal through American National Brand 'C' Company's Marketing Strategy)

  • 고희숙
    • 패션비즈니스
    • /
    • 제6권1호
    • /
    • pp.137-154
    • /
    • 2002
  • It's not easy to renew old brand of over 50 years history to the tastes of new consumer of our time. Most of national brands that has a history of some 20 years in Korea have strove for continuation and growth of brand to no avails, which can be taken as a good example of current situation. For instance, C company, one of the National brand of US which has a history of 51 years, has made its position secure as a fashion group and based itself on a sound foundation by establishing new marketing strategy and completing successful brand renewal in the process of strategic M&A with Italian company. Those successful marketing strategies are as follows. 1) they regarded both market and consumer oriented marketing activity as company's highest priority strategy and put great emphasis upon concentration on target market and reestablishment of brand image of business casual wear. 2) Setting up and operating planning team composed of merchandizer alone in Milano, they set the direction of plan on the basis of concentrated research on potential item in market according to thorough market research done by buying office in Korea, branch office in Hong Kong and buyer in US prior to blueprint planning for season. 3) Great emphasis was placed on business which focused on intensive presentation of basic key item for apparel career women who are main consumer group in the midium-low prices market in US and on supplementation of size and color. they named this line 'collectibles' and helped their customer develop their own clothes plan without worrying about the change of color and fabric by supporting same fabric and color throughout the year and enabled them to add variation easily by supplementing new trend item. 4) Company set black as a main color that lots of apparel career women find easy to care and to express their own image and presented them with pebble which belongs to navy and beige and added fashion color such as wine and brown etc as season goes by. They constructed basic line in order for their customers to coordinate purchased item with new one or to add them to present collection, and to achieve efficient sale by setting up strategy which allows this cross coordination and changing pattern occasionally. 5) Though basic jacket for 99$, short slim skirt for 49$ are products within midium-low prices range, in the material planning stage aiming at production of item that has both resonable function appealing to consumer and is fashionable, synthetic material had to be used as a main source due to price competitiveness. Despite this situation, considering comfortable sense of fit and refined drape of silhouette that has no sign of cheap material, whole collectible line was divided into two items, which contributed to reduction of cost. In case of material that is composed of triacetate and polyester in 70 to 30 ratio, was used up to 4 million yard, which allowed drastic curtailment of cost accompanied by concentration. In case of 'collectibles' line, using Korean material mainly, C company chose to have their product sewed in Southeast Asian countries where transportation is well developed and both productivity and quality verified by operating global production system which aiming at cutdown of cost through outsourcing production from the country where labor cost is low and getting finished product. Polarization between present consumers telling us that consumers with the mind of middle classes in the past no longer exists between consumers who seek after only fine article of highest quality and wise consumers who are sensible enough to judge bubble on correlation between price and quality. To cope with this change in new consumer mind, apparel makes changing their policy so as to produce item that has reasonable quality and falls within affordable price range anywhere in the world. and they're striving to get out of difficult situation by operating global marketing strategy which stresses separation of planning, production and sale and sensibility of fashion shared worldwide. The marketing strategy of C company can be exemplified as a successful one.

PDMS-SiO2·B2O3 복합막에 의한 수소-질소 기체 분리 (Separation of Hydrogen-Nitrogen Gases by PDMS-SiO2·B2O3 Composite Membranes)

  • 이석호;강태범
    • 멤브레인
    • /
    • 제25권2호
    • /
    • pp.115-122
    • /
    • 2015
  • 졸겔법에 의해서 trimethylborate (TMB)/tetraethylorthosilicate (TEOS) 몰비 0.01, 온도 $800^{\circ}C$에서 $SiO_2{\cdot}B_2O_3$가 제조되었다. 그리고 제조된 $SiO_2{\cdot}B_2O_3$와 PDMS[poly(dimethylsiloxane)]로부터 PDMS-$SiO_2{\cdot}B_2O_3$ 복합막을 제조하고 막의 물리화학적 특성을 TG-DTA, FT-IR, BET, X-ray, SEM에 의해 조사하고 그리고 $H_2$$N_2$의 투과도와 선택도를 조사하였다. TG-DTA, BET, X-ray, FT-IR 측정에 의하면 $SiO_2{\cdot}B_2O_3$는 무정형의 다공성 $SiO_2{\cdot}B_2O_3$였으며, 기공의 평균직경은 $37.7821{\AA}$, 표면적은 $247.6868m^2/g$이었다. TGA 측정에 의하면 PDMS 내에 $SiO_2{\cdot}B_2O_3$가 첨가되었을 때 PDMS-$SiO_2{\cdot}B_2O_3$ 복합막의 열적 안정성은 향상되었다. SEM 관찰에 의하면 $SiO_2{\cdot}B_2O_3$는 약 $1{\mu}m$ 크기로 PDMS 내에 덩어리 상태로 뭉쳐서 분산되어 있었다. 기체투과실험에 의하면 PDMS 내에 $SiO_2{\cdot}B_2O_3$ 함량이 증가하면 $H_2$$N_2$의 투과도는 증가하였고, 질소보다 Lenard Jones 분자지름이 작은 $H_2$의 투과도는 $N_2$의 투과도보다 컸으며, 선택도($H_2/N_2$)는 감소하였다.

이온교환된 Faujasite 제올라이트를 이용한 제올라이트 주형 탄소체 합성 시 이온 교환 금속과 탄소 전구체가 메탄 흡착 거동에 미치는 영향 (Effects of the Type of Exchanged Ions and Carbon Precursors on Methane Adsorption Behavior in Zeolite Templated Carbons Synthesized Using Various Ion-Exchanged Faujasite Zeolites)

  • 김기준;조철희;조동우
    • 청정기술
    • /
    • 제30권2호
    • /
    • pp.123-133
    • /
    • 2024
  • 대기 중에 존재하는 저농도 CH4을 제거를 위한 흡착제 개발을 위해서 Zeolite Template Carbon (ZTC)을 합성하였다. 탄소 전구체가 ZTC 합성에 미치는 영향을 알아보기 위해서, CH4와 C2H2를 탄소 전구체로 사용하여 ZTC를 합성하였으며, 또한 이온 교환에 사용된 금속의 영향을 알아보기 위해서 CaCl2와 LiCl을 사용하여 이온교환한 Y Zeolite을 Template로 사용하여 ZTC를 합성하였다. 탄소 전구체 간의 비교에서는 C2H2가 CH4 보다 더 높은 탄소 수율을 보였으며, 또한 미세기공이 발달한 ZTC를 합성하였다. 이는 C2H2의 분자 동역학적 크기(Kinetic Diameter) (3.3 Å)가 CH4의 분자 동역학적 크기(Kinetic Diameter) (3.8 Å)보다 더 작기 때문에, 제올라이트 템플릿의 미세 기공 내부의 깊숙한 곳에서부터 탄소 침착을 가능하였기 때문인 것으로 판단된다. 이온 교환에 사용된 금속 전구체 간의 비교에서는 CaCl2 기반의 ZTC가 LiCl을 기반의 ZTC보다 미세 기공이 발달한 것을 확인하였는데, 이온 교환된 Ca가 탄소 전구체에 의한 Pore Blocking을 억제해서 기공 내부로 탄소 전구체가 들어 갈 수 있게 한 덕분으로 판단된다. 합성된 ZTC를 이용하여, 298 K에서의 N2와 CH4의 흡착 등온선을 측정하였는데, 전체적으로 CH4의 흡착량이 N2보다는 높다는 것을 확인하였다. 또한 CaY 기반으로 C2H2를 이용하여 합성한 ZTC 샘플이 N2와 CH4 흡착량이 가장 높았지만, 흡착 공정 설계의 중요한 인자인 CH4와 N2의 흡착 비율 기준으론 CH4으로 합성한 샘플이 가장 높게 나왔다. 이는 N2 흡착과 관련 깊은 초미세기공이 덜 발달하여, N2의 흡착량을 줄임으로서 오히려 CH4/N2 분리도를 높게 해 주었기 때문으로 판단된다.

CNN을 적용한 한국어 상품평 감성분석: 형태소 임베딩을 중심으로 (Sentiment Analysis of Korean Reviews Using CNN: Focusing on Morpheme Embedding)

  • 박현정;송민채;신경식
    • 지능정보연구
    • /
    • 제24권2호
    • /
    • pp.59-83
    • /
    • 2018
  • 고객과 대중의 니즈를 파악하기 위한 감성분석의 중요성이 커지면서 최근 영어 텍스트를 대상으로 다양한 딥러닝 모델들이 소개되고 있다. 본 연구는 영어와 한국어의 언어적인 차이에 주목하여 딥러닝 모델을 한국어 상품평 텍스트의 감성분석에 적용할 때 부딪히게 되는 기본적인 이슈들에 대하여 실증적으로 살펴본다. 즉, 딥러닝 모델의 입력으로 사용되는 단어 벡터(word vector)를 형태소 수준에서 도출하고, 여러 형태소 벡터(morpheme vector) 도출 대안에 따라 감성분석의 정확도가 어떻게 달라지는지를 비정태적(non-static) CNN(Convolutional Neural Network) 모델을 사용하여 검증한다. 형태소 벡터 도출 대안은 CBOW(Continuous Bag-Of-Words)를 기본적으로 적용하고, 입력 데이터의 종류, 문장 분리와 맞춤법 및 띄어쓰기 교정, 품사 선택, 품사 태그 부착, 고려 형태소의 최소 빈도수 등과 같은 기준에 따라 달라진다. 형태소 벡터 도출 시, 문법 준수도가 낮더라도 감성분석 대상과 같은 도메인의 텍스트를 사용하고, 문장 분리 외에 맞춤법 및 띄어쓰기 전처리를 하며, 분석불능 범주를 포함한 모든 품사를 고려할 때 감성분석의 분류 정확도가 향상되는 결과를 얻었다. 동음이의어 비율이 높은 한국어 특성 때문에 고려한 품사 태그 부착 방안과 포함할 형태소에 대한 최소 빈도수 기준은 뚜렷한 영향이 없는 것으로 나타났다.

SANET-CC : 해상 네트워크를 위한 구역 IP 할당 프로토콜 (SANET-CC : Zone IP Allocation Protocol for Offshore Networks)

  • 배경율;조문기
    • 지능정보연구
    • /
    • 제26권4호
    • /
    • pp.87-109
    • /
    • 2020
  • 현재 육상에서는 유무선 통신의 발전으로 다양한 IT 서비스를 제공받고 있다. 이러한 변화는 육상을 넘어서서 해상에서 항해 중인 선박에서도 다양한 IT 서비스가 제공되어야 하며 육상에서 이용하는 것과 마찬가지로 양방향 디지털 데이터 전송, Web, App 등과 같은 다양한 IT 서비스들의 제공에 대한 요구가 증가될 것으로 예상하고 있다. 하지만 이러한 초고속 정보통신망은 AP(Access Point)와 기지국과 같은 고정된 기반 구조를 바탕으로 네트워크를 구성하는 지상에서는 쉽게 사용할 수 있는 반면 해상에서는 고정된 기반 구조를 이용하여 네트워크를 구성할 수 없다. 그래서 전송 거리가 긴 라디오 통신망 기반의 음성 위주의 통신 서비스를 사용하고 있다. 이러한 라디오 통신망은 낮은 전송 속도로 인해 매우 기본적인 정보만을 제공할 수 있었으며, 효율적인 서비스 제공에 어려움이 있다. 이를 해결하기 위해서 디지털 데이터 상호교환을 위한 추가적인 주파수가 할당되었으며 이 주파수를 사용하여 활용할 수 있는 선박 애드 혹 네트워크인 SANET(ship ad-hoc network)이 제안되었다. SANET은 높은 설치비용과 사용료의 위성 통신을 대신하여 해상에서 IP 기반으로 선박에 다양한 IT 서비스를 제공할 수 있도록 개발되었다. SANET에서는 육상 기지국과 선박의 연결성이 중요하다. 이러한 연결성을 갖기 위해서는 선박은 자신의 IP 주소를 할당 받아 네트워크의 구성원이 되어야 한다. 본 논문에서는 선박 스스로 자신의 IP 주소를 할당 받을 수 있는 SANET-CC(Ship Ad-hoc Network-Cell Connection) 프로토콜을 제안한다. SANET-CC는 중복되지 않는 다수의 IP 주소들을 육상기지국에서 선박들에 이어지는 트리 형태로 네트워크 전반에 전파한다. 선박은 IP 주소를 할당할 수 있는 육상 기지국 또는 나누어진 구역의 M-Ship(Mother Ship)들과 간단한 요청(Request) 및 응답(Response) 메시지 교환을 통해 자신의 IP 주소를 할당한다. 따라서 SANET-CC는 IP 충돌 방지(Duplicate Address Detection) 과정과 선박의 이동에 의해 발생하는 네트워크의 분리나 통합에 따른 처리 과정을 완전히 배제할 수 있다. 본 논문에서는 SANET-CC의 SANET 적용가능성을 검증하기 위해서 다양한 조건의 시뮬레이션을 수행하였으며 기존 연구와 비교 분석을 진행하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF