• Title/Summary/Keyword: Separation point

Search Result 613, Processing Time 0.035 seconds

Separation of Single Channel Mixture Using Time-domain Basis Functions

  • Jang, Gil-Jin;Oh, Yung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.4E
    • /
    • pp.146-155
    • /
    • 2002
  • We present a new technique for achieving source separation when given only a single charmel recording. The main idea is based on exploiting the inherent time structure of sound sources by learning a priori sets of time-domain basis functions that encode the sources in a statistically efficient manner. We derive a learning algorithm using a maximum likelihood approach given the observed single charmel data and sets of basis functions. For each time point we infer the source parameters and their contribution factors. This inference is possible due to the prior knowledge of the basis functions and the associated coefficient densities. A flexible model for density estimation allows accurate modeling of the observation, and our experimental results exhibit a high level of separation performance for simulated mixtures as well as real environment recordings employing mixtures of two different sources. We show separation results of two music signals as well as the separation of two voice signals.

Phase Separation and their Structures in $BaO-B_2O_3$ Glasses ($BaO-B_2O_3$계 유리의 상분리 현상과 유리의 구조)

  • 채수철;김철영
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.6
    • /
    • pp.25-32
    • /
    • 1986
  • Phase spearated glass is heterogeneous in microscopic point of view and the heterogeneities affect the structures of glasses. In the present work the phase separation of $BaO-B_2O_3$ glass system was investigated and the effect of $P_2O_5$ on the phase separation and crystallization was also studied in the above system. Experiments such as scanning electron microscopy X-ray diffraction and infrared spectroscopy were performed. Phase separation with $B_2O_3$ rich phase matrix and BaO rich phase droplet was observed for the glasses containing less than 6 mole% of BaO while the opposite morphology of phase separation was found for the glasses containing more than 7 mole% of BaO. Phase separation region was extended up to the glass with 22mole% of BaO when the amount of $P_2O_5$ was increased. The heat-treated glasses crystallized to BaO.$4B_2O_3$$P_2O_5$ hindered the glass from the crystalli-zation.

  • PDF

Separation of Single Channel Mixture Using Time-domain Basis Functions

  • 장길진;오영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.146-146
    • /
    • 2002
  • We present a new technique for achieving source separation when given only a single channel recording. The main idea is based on exploiting the inherent time structure of sound sources by learning a priori sets of time-domain basis functions that encode the sources in a statistically efficient manner. We derive a learning algorithm using a maximum likelihood approach given the observed single channel data and sets of basis functions. For each time point we infer the source parameters and their contribution factors. This inference is possible due to the prior knowledge of the basis functions and the associated coefficient densities. A flexible model for density estimation allows accurate modeling of the observation, and our experimental results exhibit a high level of separation performance for simulated mixtures as well as real environment recordings employing mixtures of two different sources. We show separation results of two music signals as well as the separation of two voice signals.

Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

A Study on Ground and Object Separation Techniques Utilizing 3D Point Cloud Data in Urban Air Mobility (UAM) Environments (UAM 환경에서의 3D Point Cloud Data 지면/객체 분리 기법 연구)

  • Bon-soo Koo;In-ho choi;Jae-rim Yu
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.481-487
    • /
    • 2023
  • Recently, interest in UAM (Urban Air Mobility) has surged as a critical solution to urban traffic congestion and air pollution issues. However, efficient UAM operation requires accurate 3D Point Cloud data processing, particularly in separating the ground and objects. This paper proposes and validates a method for effectively separating ground and objects in a UAM environment, taking into account its dynamic and complex characteristics. Our approach combines attitude information from MEMS sensors with ground plane estimation using RANSAC, allowing for ground/object separation that isless affected by GPS errors. Simulation results demonstrate that this method effectively operates in UAM settings, marking a significant step toward enhancing safety and efficiency in urban air mobility. Future research will focus on improving the accuracy of this algorithm, evaluating its performance in various UAM scenarios, and proceeding with actual drone tests.

The Condition Analysis about Job Satisfaction and Separation Propensity of Foodservice Industry Culinary Employee′s (외식산업 조리종사자의 직무만족과 이직성향에 대한 실태분석)

  • 이선호;김선희;김민수
    • Culinary science and hospitality research
    • /
    • v.9 no.4
    • /
    • pp.37-53
    • /
    • 2003
  • The purpose of this study was to find out efficient control plan for productivity increase. To analyze the data, the measure of question a paper was used to 5 a point measure, statistics disposition was used to SPSS, the analyze method was used to frequency analyze, trust degree analyze, difference analyze useful average value, person's correlation analyze, revolution analyze. The results of this study could be explained as follow: First, find out high change separation propensity. Secondly, was subjected important for atmosphere composition and was required strategy consideration for stable job recognition. Third, was operated affirmative to recognition about separation and was increased to job satisfaction according as a colleague relation and team work. Fourth, was increased to comparative separation propensity in case that high job satisfaction. Therefore it is required interesting labor item and treatment development about personal evaluation.

  • PDF

Competitive Phase Separation in a Crystallizable Polymer Solution

  • Lee, Hwan-Kwang
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.12-17
    • /
    • 1996
  • The structure formation by liquid-liquid(L-L) phase separation coupled with crystallization in isotactic polypropylene(i-PP). solutioos was investigated by a temperature jump experiment. A series of dialkyl phthalates with a different number of carbon atoms in the alkyl chain was used to control the interaction between polymer and solvent. Various thermal quench conditions were applied to the i-PP solutions to control systematically L-L phase separation and crystallization. A slow crystallizatina elongates the liquid droplets in the radial direction of a spherulite. A rapid crystallization under the deep quench locks-in the growth of L-L phase separation. These results indicate that the extent of L-L phase separation which exists below melting point can be successfully controlled through the proper selection of solvent and thermal conditions.

  • PDF

Application of Membranes for Organic Liquid or Vapor Separation and Design of Plasma-Graft Filling-Polymerized Membranes

  • Yamaguchi, Takeo;Nakao, Shin-ichi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.34-39
    • /
    • 1996
  • There is much recent interests in applying membrane separation technologies, especially for organic liquid and vapor separation or removing dissolved organics from water. Pervaporation separation can separate azeotropic mixtures and mixtures close to boiling point, and it has a potential for energy saving process instead of distillation. Removal of chlorinated oraganics from water is other measure application for pervaporation separation. Contaminated pollutant must be removed from water, and a pervaporation can effectively remove the pollutant. Air pollution by organic vapor recently became serious enviromncntal problem, and removing organic vapor from air is important application of the membrane technology.

  • PDF

Staging Flow Analysis with forward Ejector (전방 분출이 있는 단분리 유동해석)

  • Kwon K. B.;Yoon Y. H.;Hong S. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.145-150
    • /
    • 2004
  • In this study the numerical analysis on staging flow with forward ejector is conducted. The forward ejector plays a vital role in staging, which jets out from aftbody. This staging environment needs careful flow analysis for securing staging safety Present study investigates the steady inviscid staging flow phenomena with variation of separation distance. The performance index is forebody base pressure coefficients. The three dominant flow phenomena are observed according to separation distance which could be told as impinging stage, cavity vortex dominancy stage, and pure base flow characteristics stage. Impinging stage shows high thrust for forebody as one might think. However, important point is that cavity vortex dominancy stage can be more favorable for separation than impinging stage as one simply think in certain separation distance.

  • PDF

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.