• Title/Summary/Keyword: Separation of particles

Search Result 451, Processing Time 0.03 seconds

Study on the Air-Flow Separator of Light Particles Included in the Clod in the Production Process of Recycling Aggregates (순환골재 생산 공정상에서 공기유동을 이용한 토분에 포함된 이물질 제거장치에 관한 연구)

  • Suh, Yong-Kweon;Heo, Seong-Gyu;Park, Yong-Gi
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • In this paper, we present flow patterns around and performance of an air-flow separator by using the numerical analysis. With this separator, particles of different density are to be separated by using the drag force from the air flow. The low-density particles are designed to be separated by using inhalation through holes on a rotating drum. To obtain the flow informations needed for determining the proper design parameters, we have performed numerical simulations by using a commercial code, ANSYS CFX. Various parameter set was tested and it was found that depending on the design of drums there exist critical parameter set regarding the attachment of light particles on the drum, which is prerequisite for the separation of materials. We present here the possibility of using the present design in separation of particles mixed in the clod for use in recycling.

  • PDF

Theoretical and Experimental Studies on Optical Particle Separator (광 이동도에 대한 개념과 실험적 검증)

  • Kim, Sang-Bok;Jung, Eun-Jung;Sung, Hyung-Jin;Kim, Sang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2406-2409
    • /
    • 2008
  • The concept of optical mobility in the optical particle separation was derived. To verify the concept of the optical mobility, three particles were chosen to test the effects of optical mobility, namely, PSL, PMMA and silica particles. Three different experiments were performed. Firstly, retention distances of the different sized particles were measured and predicted. Secondly, retention distances of particles, having same size but different refractive indices, were measured and predicted. Finally, retention distances of the particles, which had the same optical mobility but very different sized and refractive indices, were measured and predicted.

  • PDF

Avantor® ACE® Wide Pore HPLC Columns for the Separation and Purification of Proteins in Biopharmaceuticals (바이오의약품의 단백질 분리 및 정제를 위한 Avantor® ACE® 와이드 포어 HPLC 컬럼 가이드)

  • Matt James;Mark Fever;Tony Edge
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.3.1-3.7
    • /
    • 2024
  • The article discusses the critical role of chromatography in the analysis and purification of proteins in biopharmaceuticals, emphasizing the importance of comprehensive characterization for ensuring their safety and efficacy. It highlights the use of Avantor® ACE® HPLC columns for the separation and purification of proteins, focusing on the analysis of intact proteins using reversed-phase liquid chromatography (RPLC) with fully porous particles. This article also details the application of different mobile phase additives, such as TFA and formic acid, and emphasizes the advantages of using type B ultra-pure silica-based columns for efficiency and peak shape in biomolecule analysis. Additionally, it addresses the challenges of analyzing intact proteins due to slow molecular diffusion and introduces the concept of solid-core (or superficially porous) particles, emphasizing their benefits over traditional porous particles for the analysis of therapeutic proteins. Furthermore, it discusses the development of Avantor® ACE® UltraCore BIO columns, specifically designed for the high-efficiency separation of large biomolecules, such as proteins, and demonstrates their effectiveness in achieving high-resolution separations, even for higher molecular weight proteins like monoclonal antibodies (mAbs). In addition, it underscores the complexity of analyzing and characterizing intact protein biopharmaceuticals, requiring a range of analytical techniques and the use of wide-pore stationary phases, operated at elevated temperatures and with relatively shallow gradients. It highlights the comprehensive range of options offered by Avantor® ACE® wide pore columns, including both fully porous and solid-core particles, bonded with a variety of complementary stationary phase chemistries to optimize selectivity during method development. The use of ultrapure and highly inert base silica is emphasized for enabling the use of lower concentrations of mobile phase modifiers without compromising analyte peak shape, particularly beneficial for LC-MS applications. Then the article concludes by emphasizing the significance of reversed-phase liquid chromatography and its compatibility with mass spectrometry as a valuable tool for the separation and analysis of intact proteins and their closely related variants in biopharmaceuticals.

  • PDF

Sediment Treatment by a Centrifugal Device (원심분리 장치를 이용한 퇴적물 처리)

  • Lee, Yong-Sik;Jo, Young-Min;Oh, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.4 s.96
    • /
    • pp.342-348
    • /
    • 2001
  • The present work is to introduce the preliminary experimental results for a primary hydrocyclones process in lake sediment thickening. A few cyclones based on the Rietema standard geometry were prepared. The test particles were sediments from a local lake and waste coal fly ash for a reference test. As a result of the chemical analysis, organic contaminants were abundantly found in smaller particles in overflow. Experimental results showed that the physical characteristics of particles, configuration of the cyclone and operating variables including feed solids concentration and volumetric flow rate could affect the separation efficiency. The limiting feeding velocity for the separation and enrichment of particles was 1.5 m/s, higher separation efficiency, in general, was obtained under the high velocity with the small cyclones.

  • PDF

The Electrode Shape for the Efficient Separation of Cell in Dielectrophoresis-Activated Cell Sorter (유전영동을 이용한 입자분리기의 효율적인 분리를 위한 전극 형태)

  • An, Jae-Min;Chae, Seung-Yeub;Park, Seok-Ho;Kim, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • This paper presents the optimal shape of microelectrode that generates dielectrophoretic(DEP) force to separate particles in homogeneous medium. The principle of the particles sorting is based on the use of the relative strengths of negative DEP (nDEP) and drag forces, as in a general DEP-activated cell sorter (DACS). To numerically calculate the DEP force and drag force, the simulation is implemented in MATLAB 7.0. The properties of particles, which are used in simulation, are similarly selected as those of cells to apply cell separation. The most optimized shape of electrode is selected by numerical simulation according to a variety of electrode shape such as rectangle, trapezoidal, and right-triangle. Through, in addition, parameter study, we found that applied frequency is more significant factor on the separation than various parameters, such as applied voltage and permittivity of medium, that decide on the strength of DEP force.

Separation of micro-plastics from sea water using electromagnetic archimedes force

  • N. Nomura;F. Mishima;S. Nishijima
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.18-21
    • /
    • 2023
  • Pollution of the environment by micro-plastics is now a worldwide problem. Plastics are difficult to decompose and put a great load on the marine environment. Especially a plastic with a size of 5 mm or less is defined as micro-plastic and are carried by ocean currents over long distances, causing global pollution. These are not easily decomposed in the natural environment. In this paper, we aimed to experimentally demonstrate that micro-plastics in seawater can be continuously separated by electromagnetic Archimedes force. Using polyethylene particles of 3 mm in diameter as the separation target, a flow channel was fabricated and separation conditions were investigated by particle trajectory calculations for separation experiments. Based on the calculation results, a solenoid-type superconducting magnet was used as a source of magnetic field to conduct separation experiments of micro-plastics in seawater. Although a high separation rate was assumed in the simulation results, the experimental results did not show any significant improvement in the separation rate due to the electromagnetic Archimedes force. It was found that the gas generated by the electrolytic reaction may have inhibited the migration of the particles.

Ground Organic Monolith Particles Having a Large Volume of Macropores as Chromatographic Separation Media

  • Lee, Jin Wook;Ali, Faiz;Kim, Yune Sung;Cheong, Won Jo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.7
    • /
    • pp.2033-2037
    • /
    • 2014
  • A reaction mixture was developed for formation of soft organic monolith that was easily smashed, rinsed, refluxed, filtered, and dried to give monolith particles having high pore volume of macropores. This phase was almost without mesopores. The reaction mixture was composed of methacrylic acid, ethylene glycol dimethacrylate, polyethylene glycol (porogen), and an initiator in a mixed solvent of toluene and isooctane. The selection of porogen and its amount was carefully carried out to obtain the optimized separation efficiency of the resultant phase. The median macropore size was 1.6 ${\mu}m$, and the total pore volume was 3.0-3.4 mL/g. The median particle size (volume based) was 15 ${\mu}m$, and the range of particle size distribution was very broad. Nevertheless the column (1 ${\times}$ 300 mm) packed with this phase showed good separation efficiency (N~10,000-16,000) comparable to that of a commercial column packed with 5 ${\mu}m$ C18 silica particles.

Magnetic Separation of FCC Equilibrium Catalyst by HGMS

  • Xiang, Fazhu;He, Pingbo;Chen, Jin
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.770-775
    • /
    • 2001
  • Effects of magnetic field and carrier gas velocity on the magnetic separation of FCC catalyst by a high gradient magnetic separator were studied. The activities of the equilibrium catalyst, the magnetic particles and the nonmagnetic particles were evaluated in a fixed bed microreactor The results showed that heavy metal contaminated catalyst can be selectively separated by means of high gradient magnetic separation at magnetic field 0.5T and carrier gas velocity 0.3m.s$^{-1}$ , and lightly metal contaminated catalyst retained high catalytic activity.

  • PDF

Trajectory Simulation of ASR Particles in Induction Electrostatic Separation (유도형 정전선별에서 ASR 입자의 궤적모사)

  • Kim, Beom-uk;Park, Chul-hyun
    • Resources Recycling
    • /
    • v.28 no.6
    • /
    • pp.96-105
    • /
    • 2019
  • Automobile shredder residue (ASR) is the final waste produced when end-of-life vehicles (ELVs) are shredded. ASR can be separated using mineral-processing operations such as comminution, air classification, magnetic separation, and/or electrostatic separation. In this work, trajectory analyses of conductors (copper) and non-conductors (glass) in the ASR have been carried out using induction electrostatic separator for predicting or improving the ASR-separation efficiency. From results of trajectory analysis for conductors, the trajectories of copper wire by observation versus simulation for coarse particles of 0.5 and 0.25 mm showed consistent congruity. The observed 0.06 mm fine-particles trajectory was deflected toward the (-) attractive electrode owing to the charge-density effects due to the particle characteristics and relative humidity. In the case of non-conductors, the actual trajectory of dielectric glass deflected toward the (-) electrode, showing characteristics similar to those of conductive particles. The analyses of stereoscopic microscope and SEM & EDS found heterologous materials (fine ferrous particles and conductive organics) on the glass surface. This demonstrates the glass decreasing separation efficiency for non-ferrous metals during electrostatic separation for the recycling of ASR. Future work will require a pretreatment process for eliminating impurities from the glass and advanced trajectory-simulation processes.

Vibration Analysis of Separation Screen for a Recycling of Construction Wastes (건설폐기물의 재활용을 위한 분리스크린의 진동해석)

  • Kim, K.K.;Kim, M.S.;Son, K.;Kim, K.H.;Moon, B.Y.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1057-1062
    • /
    • 2007
  • The purpose of this study is to find out design parameters of vibrating screen, such as particles motion, specific gravity, shape, and kinetic friction. In order to approach this problem, four materials of construction wastes, wood, styrofoam, concrete, and sand are used for dynamic modeling. To present friction between the particles material and tilt plates material, these particles model is applied in order to verify effectively. Generally, the vibrating screen is composed of three assemblies such as screen, wastes guide, supported of screen. This model regards vibrator as system of screen fixed tilt plates. The model is analyzed to present what kind of particles motion while the system is vibrating. and this vibration system has been implemented in a ADAMS dynamaic program. This modeling is consist of dynamic model separation state on particle size. This study make good technique to verify in theory.

  • PDF