• Title/Summary/Keyword: Separation of particles

Search Result 449, Processing Time 0.025 seconds

Reduction of Salt Concentration in Food Waste by Salt Reduction Process with a Rotary Reactor (로터리식 저염화 공정설비에 의한 음식물 쓰레기의 염분농도 저감)

  • Kim, Wi-sung;Seo, Young-Hwa
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.1
    • /
    • pp.61-70
    • /
    • 2005
  • In order to reduce salt(as NaCl) contents in food waste and to improve the quality of discharged wastewater produced during the recycling process of food waste for the purpose of compost and feed stuff, a salt reduction process by added water into food waste was developed. The pilot plant with a rotary type salt reduction equipment to manage continuously 0.5 ton food waste per hour was constructed and the efficiency was tested. The amount of added water was calculated by the water content and the efficiency of dewatering process of food waste. Approximately 0.8 liter water per a kilogram of food waste was injected into the reactor in which food waste was pouring simultaneously, then diluted/mixed in a rotary reactor. About 1.1 liter of leachate including added water was generated, but the leachate contained a very high content of organic particles, so most particles were recovered by two step solid-liquid separation process. The first step was a gravitational filtering process using screens with a pore diameter of 1mm, and the second separation process was centrifugal process. Organic quality of food waste which had been desalted was maintained by inputting the entirely recovered organic particles. The efficiency of salt reduction of food waste was estimated by measuring a chloride anion by titration and salinity by a probe. The results by the two different measuring methods were always over 50%, and the quality of final wastewater was improved up to $200mg/{\ell}$ as TS(total solid) by an additional settling process after the two step solid-liquid separation process.

  • PDF

TiO2 Removal using Electrocoagulation-electroflotation Two-step Process (전기응집-전기부상 2단계 공정을 이용한 TiO2 제거)

  • Dong-Seog Kim;Young-Seek Park
    • Journal of Environmental Science International
    • /
    • v.32 no.5
    • /
    • pp.385-394
    • /
    • 2023
  • There is a need for a method that can effectively remove wastewater containing small-sized particles such as TiO2. In this study, we attempted to remove TiO2 wastewater using electrocoagulation-electroflotation two-step separation. The TiO2 wastewater was effectively removed via batch electrocoagulation-electroflotation separation. However, in the batch process, the simultaneous operation of electrocoagulation and electoflotation was challenging due to the high residual turbidity. In the continuous operation, electrocoagulation and electoflotation reactors were kept separate. The turbidity removal in continuous operation was similar to that in the batch process, nevertheless, the residual Al concentration was high, leading to the conclusion that counterterm ensures against residual Al were necessary.

Enrichment of valuable elements from vanadium slag using superconducting HGMS technology

  • He, Sai;Yang, Chang-qiao;Li, Su-qin;Zhang, Chang-quan
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.17-21
    • /
    • 2017
  • Vanadium slags is a kind of vanadiferous solid waste from steelmaking process. It not only occupies land, pollutes environment, but also leads to waste of resources. Based on the difference of magnetic susceptibility of different particles caused by their chemical and physical properties from vanadium slag, a new technology, superconducting high gradient magnetic separation was investigated for separation and extraction of valuable substances from vanadium slag. The magnetic concentrate was obtained under optimal parameters, i.e., a particle size -200 mesh, a magnetic flux density of 0.8 T, a slurry concentration of 5 g/L, an amount of steel wools of 25 g and a slurry flow velocity of 2 L/min. The content of $Fe_2O_3$ in concentrate could be increased from 39.6% to 55.0% and $V_2O_5$ from 2.5% to 4.0%, respectively. The recovery rate is up to 42.9%, and the vanadium slag has been effectively reused.

Blind Audio Source Separation Based On High Exploration Particle Swarm Optimization

  • KHALFA, Ali;AMARDJIA, Nourredine;KENANE, Elhadi;CHIKOUCHE, Djamel;ATTIA, Abdelouahab
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2574-2587
    • /
    • 2019
  • Blind Source Separation (BSS) is a technique used to separate supposed independent sources of signals from a given set of observations. In this paper, the High Exploration Particle Swarm Optimization (HEPSO) algorithm, which is an enhancement of the Particle Swarm Optimization (PSO) algorithm, has been used to separate a set of source signals. Compared to PSO algorithm, HEPSO algorithm depends on two additional operators. The first operator is based on the multi-crossover mechanism of the genetic algorithm while the second one relies on the bee colony mechanism. Both operators have been employed to update the velocity and the position of the particles respectively. Thus, they are used to find the optimal separating matrix. The proposed method enhances the overall efficiency of the standard PSO in terms of good exploration and performance. Based on many tests realized on speech and music signals supplied by the BSS demo, experimental results confirm the robustness and the accuracy of the introduced BSS technique.

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

Micro Pre-concentration and Separation of Metal Ions Using Microchip Column Packed with Magnetic Particles Immobilized by Aminobenzyl Ethylenediaminetetraacetic Acid

  • Kim, Y.H.;Kim, G.Y.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.905-909
    • /
    • 2010
  • Magnetic beads (Dynabeads$^{(R)}$) embedded in ~1 micron size polystyrene beads bearing surface carboxylic acid groups were modified with aminobenzyl ethylenediaminetetraacetic acid (ABEDTA) to concentrate or separate metal ions using pH gradients on micro and nano scales. The immobilization of ABEDTA was achieved by amide formation. The presence of the metal chelating functional group in the fully deprotonated form was confirmed by FT-IR. The chelation efficiency of beads was tested by determining metal ions in supernatant using GFAAS when pH gradients from 3 to 7. Mixtures of Cu and Mg and of Cd and Mn (at 10 ng/mL of metal) were separated as the difference in formation constant with the functional group of ABEDTA. The separation was repeated twice with relative standard deviation of <18%. A polydimethylsiloxane (PDMS) microchip column packed with EDTA-coated magnetic beads was optimized to concentrate metal ion for practical applications by eluting a Cu solution of micro scale at pH 3.

Flow Characteristics of Fine Particles for Separated Device Shapes (분리장치의 형상에 따른 미립자 유동특성)

  • Hwang, Seon Kyeong;Lee, Seoung Soo;Jung, Hyo Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.544-551
    • /
    • 2013
  • Recently high speed mixer, which is mixing, grinding, dispersion for liquid-liquid material, has been widely used several industries such as food, cosmetics, pharmaceuticals, fine chemicals, electronic material. This high speed mixer has a core element part called particle separation device. Particle separation device, which makes mixed liquid and liquid material using shear forces from a rotor and a stator, is a decisive factor in the distributed parts. In this study, we examined the velocity distribution of the two models of particle separation device using computation fluid dynamics, so that we were able to see the difference of the velocity distribution according to the shape. Also, by experiment, we observed that the use of rotor-screen type is deemed more suitable in case of accurately considering the effect of improving of the dispersibility through the circulation of the future.

Development of a Simulation Model for Separation Analysis and Design of Star Screen in Construction Wastes Recycling (건설폐기물 선별 해석을 위한 치차형 스크린 해석모델 개발)

  • Kim, Kwang-Hoon;Park, Jung-Hong;Moon, Byung-Young;Park, Yong-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.213-218
    • /
    • 2010
  • In this study, a star screen model was constructed to predict the dynamic characteristics of interactive waste particles and to simulate separation capability of the particle using geared type screen(star screen). In order to approach this model, it is necessary to determine the design parameters of the screen such as driving torque, percentage of open space, and capability. Thus, a dynamic star screen model was developed with a total of 32 columns of geared assembly including screen part, wastes guide, and extra joints to rotate the screen using ADAMS. Each parameter was simulated to predict the screening capability for particle size, rotating speed, and particle condition. From the results, separation ability was predicted according to the affecting variables by using the dynamic star screen model.

DEVELOPMENT AND TESTING OF MEDIUM CAPACITY GRAIN FLOUR SEPARATOR

  • Kachru, Rajinder-P
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.966-978
    • /
    • 1993
  • A power operated 90.5 hp electric motor) grain flour separator was designed and developed for separation of grain (wheat, corn, chickpea and soybean) flour into various fractions based on the size of the particles of the product. The separator agitating mechanism, feed control, cylindrical separator unit and an eccentric mechanism. The machine was tested for wheat ( variety ; Sujata) flour separation into four fractions, viz ; semolina, Gr-I and II, flour (coarse) and white (fine) flour. Wheat samples (6.8% m.c., db) were first pearled by CIAE pearler for 15.8% bran removal . The pearled wheat grains were then milled for semolina by a burre mill. The product and machine characteristics were determined at different capacities varying from 24 kg/h to 143 kg/h. It was found that 76 kg/h capacity gave reasonably best results in terms of purity and recovery of semolina vis-a-vis the market product. The energy requirement of the machine at no-load was found to be 230 W and at load c nditions, it varied between 36.3-6.4 KJ per kg of fead seperation. The macine could be used by small flour millers small/medium size traders and retailers and other processors for making available various flour products of different particle size in the market for ready use of the consumers.

  • PDF

Detection of Fish Virus by Using Immunomagnetic Separation and Polymerase Chain Reaction (IMS-PCR)

  • KIM Soo Jin;OH Hae Keun;CHOI Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.6
    • /
    • pp.948-955
    • /
    • 1997
  • Immunomagnetic separation of virus coupled with .reverse transcription-polymerase chain reaction (IMS-PCR) was performed with infectious hematopoietic necrosis virus (IHNV). A DNA fragment of expected size was synthesized in the RT-PCR with total RNA extracted from IHNV inoculated CHSE-214. In a SDS-PAGE analysis, a protein band of over 70kDa was detected from non-infected cells and cells inoculated with IHNV and infectious pancreatic necrosis virus (IPNV). This protein was detected in the Western blot analysis probably because of non-specific reaction to monoclonal antibody against IHNV nucleocapsid protein. In the immunomagnetic separation, magnetic beads coated with monoclonal antibody against the IHNV nucleocapsid protein was incubated with supernatant from IHNV inoculated CHSE-214 cells. During this process, the non-specifically reacting protein could be removed by washing the magnetic bead with PBS in the presence of an external magnetic field, and viral proteins were detected from the remaining, cleaned magnetic beads. It was necessary to extract viral RNA from the captured virus particles before RT-PCR, and no DNA product was detected when the captured virus was only heated 5 min at $95^{\circ}C$. A PCR-product of expected size was synthesized from IMS-PCR with magnetic beads double coated either by goat anti-mouse IgG antibody -monoclonal antibody or streptavidin - biotin conjugated monoclonal antibody.

  • PDF