• Title/Summary/Keyword: Separation filter

Search Result 258, Processing Time 0.032 seconds

Hybrid Sensor-less Control of Permanent Magnet Synchronous Motor in Low-speed Region

  • Yamamoto, Yasuhiro;Funato, Hirohito;Ogasawara, Satoshi
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.301-308
    • /
    • 2008
  • This paper proposes a method of improving the stability in sensor-less control of permanent magnet synchronous motors. The control method for low-speed region is divided into two: One is a high frequency method, which involves a problem of reverse rotation once misdetection of the permanent magnet polarity should occur, and another one is a current drive method, which has a problem that phase and speed oscillations are caused by quick speed changes. Hence, authors propose adoption of the current drive method for the basic control system with added compensation of stabilization by means of the high frequency method. This combination secures stable control with no risk of reversal and less vibration. In addition, authors have also considered a frequency separation filter of a shorter delay time so that current control performance will not lower even when high frequencies are introduced. This filter has achieved simplified compensation using repetitive characteristic through the utilization of the periodicity of high frequency current. Simulation and experiment have been conducted to verify that the stable performance of this system is improved.

Determination of relevant Characteristics for Cartridge Filters

  • Ogawa, Takao
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.04a
    • /
    • pp.1-11
    • /
    • 1993
  • Cartridge filters are widely used in liquid-solid separation processes. To select a proper filter system for the requirements of a given application, a knowledge of filter efficiency and dirt capacity is required. The filter manufacturer needs to provide data which are based on test procedures simulating real parameters on a laboratory scale. There does not exist at present a standard for liquid filter testing (with the exception of the Multipass Test to ISO4752 for hydraulic filters). Users have to work with data based on different test procedures. This paper will discuss principles of filter testing, efficiency andd dirt capacity results as a function of test parameters, and data interpretion to provide a guideline for the end user.

  • PDF

Experimental Study on Synthetic Fiber Filled Channel for Treating Turbid Water at the Construction Sites and Protecting Drain System (합성섬유 충진 여과수로를 이용한 건설사업장의 흙탕물 처리 및 배수구 보호에 관한 실험적 연구)

  • Yuan, Qingke;Cheng, Jing;Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.537-545
    • /
    • 2016
  • In order to cope with the new and strict government regulations for turbid water discharge from construction sites, this study tested whether synthetic fiber filters can replace conventional best management practices. The filter efficiency was about 10 to 60% with a varying filter depth of 5 to 15cm, presuming extreme storm flow conditions to be in the range of 800 to 1500m/day of filtration rates. Fiber filter acts exactly like a granular filter, i.e. the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. Based on the operational data, we suggested the Log-Log design relationship, which can be used to determine the filter depth and area. Compared to the widely used gravel filter which treats the turbid water at the construction site, about 20% higher efficiency was obtained under similar operating conditions. Cleaning the filter through a simple hand-washing method at the time of break-through, achieved about 90% soil recovery.

A New Estimate for the Natural Rate of Unemployment based on Job Finding and Separation Rates (구직률과 이직률을 활용한 자연실업률의 추정)

  • Kwon, Kyu Baek;Kim, Hyung Seok;Lee, Yoonsoo
    • Journal of Labour Economics
    • /
    • v.38 no.2
    • /
    • pp.1-24
    • /
    • 2015
  • We estimate the natural rate of Unemployment in Korea, using job finding and separation rates. The estimation results suggest that both job finding and separation rates of Korea have increased after the 1997 Asian Financial Crisis. However, we don't find evidence of significant increase in the trend of the natural rate of unemployment. Overall our finding suggests that both job creation and destruction have increased.

  • PDF

Sludge Thickening Performance of the Filtration Bio-reactor Equipped with Shadow Mask Filter Module (Shadow mask 여과 모듈을 이용한 슬러지 농축 특성)

  • Jung, Yong-Jun;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.29-33
    • /
    • 2005
  • In order to recycle the waste material and to develop the thickening unit of waste activated sludge from wastewater treatment facilities, the filtration bio-reactor equipped with a shadow mask filter module was employed for this work from which the operating properties and parameters were drawn. The sludge thickening and filtration unit is made of cylindrical acryl tank(12cm i.d. ${\times}$ 58cm height: working volume of 6L), where the flat-sheet type of shadow mask filter module(pore size: 220~250um, opening area: 34.8~39.6%) was installed and the effluent was withdrawn from the effluent port at the lowest point of the reactor, and the filtration was performed only by the hydraulic pressure. For evaluating the operating performance of this reactor, some parameters such as the solid-liquid separation of different biomass concentrations, the water quality of filtrate, the aeration cleaning time and the cleaning effect were investigated. Depending on the MLSS concentrations, the different time to withdraw 3L of filtrate was required in which the longer filtration time was necessary for the higher MLSS concentrations caused by the thicker formation of cake layer: 40 minutes for 5,000 mg/L, 70 minutes for 10,000 mg/L and 100 minutes for 15,000 mg/L, where the concentrations of SS were 8.9, 6.7 and 6.5 mg/L, respectively. Under the same operating conditions (the intensity of aeration cleaning: 80 L/min, MLSS: 10,000 mg/L), the proper aeration cleaning time was revealed 30 seconds, and the stable formation of cake layer was in the range of 10 to 15 minutes. Therefore, the shadow mask considered as a waste material can be of use as a filter material for the sludge thickening system.

Robust Blind Source Separation to Noisy Environment For Speech Recognition in Car (차량용 음성인식을 위한 주변잡음에 강건한 브라인드 음원분리)

  • Kim, Hyun-Tae;Park, Jang-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.89-95
    • /
    • 2006
  • The performance of blind source separation(BSS) using independent component analysis (ICA) declines significantly in a reverberant environment. A post-processing method proposed in this paper was designed to remove the residual component precisely. The proposed method used modified NLMS(normalized least mean square) filter in frequency domain, to estimate cross-talk path that causes residual cross-talk components. Residual cross-talk components in one channel is correspond to direct components in another channel. Therefore, we can estimate cross-talk path using another channel input signals from adaptive filter. Step size is normalized by input signal power in conventional NLMS filter, but it is normalized by sum of input signal power and error signal power in modified NLMS filter. By using this method, we can prevent misadjustment of filter weights. The estimated residual cross-talk components are subtracted by non-stationary spectral subtraction. The computer simulation results using speech signals show that the proposed method improves the noise reduction ratio(NRR) by approximately 3dB on conventional FDICA.

  • PDF

Design and Analysis of Color Separation Grating by Using Fresnel Diffraction Theory

  • Chen, Chien-Hung;Lin, Hoang-Yan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1505-1509
    • /
    • 2006
  • We use the color separation grating (CSG) to split colored light into the sub-pixel of LCD to enhance the optical efficiency as compared with that of using color filter. Based on the Fresenl diffraction theory, the theoretical optical efficiency can reach 66-81%, ranging almost from 2 to 2.5 times of that using color filters.

  • PDF

A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot (슬러리 양돈분뇨의 최적 고액분리 방안 연구)

  • Park, Seung-Kyun;Choi, Jae-Gil;Chung, Yoon-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.60-70
    • /
    • 2000
  • The swine wastewater from slurry feedlot has been a social problem in Korea since the proper treatment is very difficult. Therefore, a practical study on the Solid-Liquid separation of swine wastewater from slurry feedlot was carried out as a pan of pretreatment for the successful biological treatment. The appropriate type of coagulant and optimum dosage were proposed for the most efficient Solid-Liquid separation and the best Solid-Liquid separation methods for different size of feedlot were determined through the tests with field-scaled Solid-Liquid separation equipment. The appropriate coagulant for the conditioning of dewatering property was E-851, which is a cationic polyelectrolyte made of polyacrylamide, and the optimum dosage was 0.24~0.6% of unit solids weight. Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, High-speed Screw Decanter, Low-speed Screw Decanter, and Dissolved Air Flotation Process had been investigated in this study. According to the results, the Screw Press was the best dewatering equipment for the small & medium size for feedlot and low-speed Screw Decanter was the best for the large size feedlot & public owned treatment facilities for the primary Solid-Liquid separation, and the most suitable secondary treatment process was DAF. On the other hand, reductions for the requirement of bulking agent and organic loading by Solid-Liquid separation process were 94.8% and 84.7%, respectively Therefore, the Solid-Liquid separation process must be required for the successful treatment of swine wastewater from slurry feedlot.

  • PDF

Triacetin이 탄소복합 필터의 연기성분 흡착능에 미치는 영향

  • 김정열;신창호;김종열
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.2
    • /
    • pp.205-209
    • /
    • 1998
  • This study was conducted to evaluate the effect of triacetin(TA) treatment during manufacturing carbon dual filter for the adsorption of cigarette smoke components by activated carbons. The measurements were carried out by separation of activated carbon from carbon dual filter, and the specific surface area analyzed. The specific surface area of activated carbon from the domestic cigarette filter and from the foreign cigarette filter by degassing at 9$0^{\circ}C$ was 163$\pm$32$m^2$/g, and 16.6$\pm$1.9$m^2$/g, respectively. Those values were very lower than that of degassing at 35$0^{\circ}C$ (Domestic brand: 952$\pm$30$m^2$/g, and Foreign brand: 847$\pm$73$m^2$/g). By comparing the adsorption capacity of acetone and benzene with and without triacetin treated activated carbon, there was a 20% reduction of adsorption capacity by 5% triacetin treatment. Also, from the cilia toxicity test with carbon dual filter treated 0 % TA and 8 % TA, the cilia survival time was 706$\pm$74sec. and 603$\pm$64sec. for 0% TA and 8% TA, respectively. The delivery rate of vapour phase of cigarette smoke, which consists of main components of cilia toxicity, was higher at 8% TA filter than 0 % TA filter. Our results indicate that the treated TA covered the micro-pore of activated carbon, and then reduced specific surface area, finally, decreased the adsorption of vapour phase from cigarette smoke.

  • PDF

Numerical Analysis of Flow Characteristics of the Filter for Separating Oil Mist from Blow-by Gas (블로바이 가스 내 오일입자들을 제거하기 위한 필터의 유동특성 수치해석)

  • Yun, Jeong-Eui;Chae, Kangseog;Kang, Hyukjin;Chung, Doyoung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.549-555
    • /
    • 2016
  • This research was performed to determine the oil separation characteristics of the specially designed oil filter installed in a PCV cylinder head passage. The oil filter was specially designed with fleece for separating oil mist from blow-by gas. The fleece, made of fiber fabric material, is placed in the oil filter case to absorb oil mist with a small pressure drop during blow-by gas through the filter. To do this, 3-D CFD analysis was simulated for the simplified PCV system with the oil filter using the commercial code, Ansys CFX. Results showed that the oil filter's efficiency with fleece sharply increased as oil droplet size increased.