• 제목/요약/키워드: Separation Potential

검색결과 496건 처리시간 0.029초

만성 흡인에 대한 후두기관 분리술의 유용성 (Laryngotracheal Separation for Chronic Intractable Aspiration)

  • 이강진;성명훈;박범정;성원진;노종렬;민양기;이철희;이재서;김광현
    • 대한기관식도과학회지
    • /
    • 제7권2호
    • /
    • pp.140-145
    • /
    • 2001
  • Background and Objectives: Intractable aspiration in patients with impaired protective function of the larynx often results in multiple episode of aspiration pneumonia, repeated hospitalizations and expensive nursing care. The purpose of this study was to review the authors’experience and Patient outcome with the laryngotracheal separation (LTS) procedure. Materials and Methods A retrospective review of 9 patients who underwent LTS between 1996 and 2001 was conducted. Ages ranged from 3 to 72 years. Results : Seven patients were expected to have morbid aspiration as a consequence of acquired neurologic injuries and two were congenital neurologic injuries. Two patients had a postoperative fistula, which was well controlled with local wound care and minor procedure. Following LTS, aspiration was effectively controlled in all patients and four were able to tolerate a regular diet. Conclusion : LTS is a low-risk, successful. definitive procedure which decreases the potential for aspiration, pulmonary complication, hospitalizations and increases quality of life, especially in patent with irreversible upper airway dysfunction and Poor speech potential.

  • PDF

Isolation of Listeria monocytogenes by Immunomagnetic Separation and Atomic Force Microscopy

  • Mercanolu, Birce;Aykut, S.;Ergun, M.Ali;Tan, Erdal
    • Journal of Microbiology
    • /
    • 제41권2호
    • /
    • pp.144-147
    • /
    • 2003
  • Listeria monocytogenes is a pathogen of major concern to the food industry and the potential cause of severe infections such as listeriosis. Early detection of this foodborne pathogen is important in order to eliminate its potential hazards. So, immunomagnetic separation (IMS) has been suggested as a means of reducing the total analysis time and for improving the sensitivity of detection. Atomic force microscopy (AFM) has been used for measuring the topographic properties of sample surfaces at nanometer scale. In this study, we used AFM to confirm both the sensitivity and the specificity of IMS. Regarding AFM analysis, the length and the width of the bacteria, which were in agreement with literature values, were found to be 2.993 $\mu\textrm{m}$ and 0.837 $\mu\textrm{m}$, respectively. As a result, AFM helped us both characterize and measure the bacterial and bead structures.

퍼텐셜 자료의 깊이 분리 (Separation-sounding Filter for Potential Data)

  • 박영수;임무택;임형래
    • 지구물리와물리탐사
    • /
    • 제15권2호
    • /
    • pp.51-56
    • /
    • 2012
  • 특정한 지질 구조에 의한 이상을 분리하는 문제, 특히 깊이가 다른 샘들에 의하여 중첩된 이상을 수직적으로 분리하는 문제는 중력과 자력탐사 자료 해석에서 매우 필수적이며 중요한 과정이라 할 수 있다. 측정된 퍼텐셜 자료를 단순하게 광역 효과와 남은 이상의 합으로 가정할 수도 있지만, 수직적으로 여러 층인 구조인 경우로 확장하여 특정한 층에 의한 효과를 분리해 내거나 분리된 이상을 깊이에 관하여 정량적으로 규정할 수 있으면, 이것은 깊이 분리라고 부를 수 있을 것이다. 깊이 분리 필터로서 로그 파워 빛띠 분석을 이용한 진동수 필터를 제안한다. 이것을 수치 모델링과 흥해 일대에서 얻은 실제 중력탐사 자료에 적용하였으며, 2 배 깊이만큼 위로 연속 필터와 비교, 검토해 보았다. 수치 모델링과 실제 중력 자료에 적용한 바에 의하면, 이 논문에서 제안한 깊이 분리 필터는 지구물리적인 의미가 있는 중력 불연속면까지의 중력 효과를 잘 벗겨냄으로써 불연속면의 중력 분포를 추정하여 지질 구조를 해석하는 데에 유용한 도구임을 보여주었다.

자력선별법에 의한 선탄의 탈황 (COAL DESULFURIZATION BY MAGNETIC SEPARATION METHODS)

  • 전호석;이재장
    • 산업기술연구
    • /
    • 제15권
    • /
    • pp.175-185
    • /
    • 1995
  • Under the new environmental regulations announced by the government, utilities will have to cut their sulfur dioxide emissions by 60% from 1991 levels by the year of 1999. Sulfur dioxide emissions can be reduced prior to combustion by physical, chemical or biological coal cleaning. The new technology of high gradient magnetic separation (HGMS) offers the potential of economic separatoins of a variety of fine, weakly magnetic minerals including inorganic sulfur and many ash-forming minerals from coals. In the present paper, magnetic separation tests have been conducted on Korean anthracite and high-sulfur Chinese coal to investigate the feasibility of these techniques for reducing sulfur content from coals. In wet magnetic separation, the studied operating parameters include particle size, pH, matrix types, feed solids content, feed rate, number of cleaning stages and etc. The results shows that for wet separation, 60~70% of total sulfur was removed from coals with over 80% combustible recovery, on the other hand, for dry separation, 47.6% of total sulfur was removed from coals with 75% recovery.

  • PDF

Molecularly engineered switchable photo-responsive membrane in gas separation for environmental protection

  • Rosli, Aishah;Low, Siew Chun
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.447-461
    • /
    • 2020
  • In recent years, stimuli-responsive materials have garnered interest due to their ability to change properties when exposed to external stimuli, making it useful for various applications including gas separation. Light is a very attractive trigger for responsive materials due to its speedy and non-invasive nature as well as the potential to reduce energy costs significantly. Even though light is deemed as an appealing stimulus for the development of stimuli-responsive materials, this avenue has yet to be extensively researched, as evidenced by the fewer works done on the photo-responsive membranes. Of these, there are even less research done on photo-responsive materials for the purpose of gas separation, thus, we have collected the examples that answer both these criteria in this review. This review covers the utilisation of photo-responsive materials specifically for gas separation purposes. Photo-chromic units, their integration into gas separation systems, mechanism and research that have been done on the topic so far are discussed.

송전철탑 부근의 대지전위 억제를 위한 이적거리 산정모델 연구 (A Study on Separation Distance Calculation Model for Limitation of Earth Potential Rise nearby Tower Footings)

  • 최종기;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.212-213
    • /
    • 2007
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system. In this paper, an analytical formula to calculate the requried sepeartion distance from the faulted tower has been derived.

  • PDF

공유 유기 골격체 기반 복합 분리막 : 고찰 (Covalent Organic Framework Based Composite Separation Membrane: A Review)

  • 심정환;라즈쿠마 파텔
    • 멤브레인
    • /
    • 제33권4호
    • /
    • pp.149-157
    • /
    • 2023
  • 공유 유기 프레임워크(COF)는 분자 분리, 염료 분리, 가스 분리, 여과 및 담수화를 포함한 다양한 응용 분야에서 가능성을 보여주었습니다. COF를 막에 통합하면 투과성, 선택성 및 안정성이 향상되어 분리 공정이 향상됩니다. 단일 벽 탄소 나노튜브(SWCNT)와 COF를 결합하면 염료 분리에 이상적인 높은 투과성과 안정성을 가진 나노 복합막을 생성합니다. COF를 폴리아미드(PA) 막에 통합하면 합성 계면 전략을 통해 투과성과 선택성이 향상됩니다. 혼합 매트릭스 막(MMM)의 3차원 COF 필러는 CO2/CH4 분리를 향상시켜 바이오가스 업그레이드에 적합합니다. COF와 금속 유기 프레임워크(MOF) 막을 결합한 모든 나노 다공성 복합재(ANC) 막은 투과성-선택성 트레이드오프를 극복하여 가스 투과성을 크게 향상시킵니다. 가상 COF (hypoCOF)를 사용한 계산 시뮬레이션은 CO2 분리 및 H2 정제와 관련하여 우수한 CO2 선택성과 작업 능력을 입증합니다. 박막 복합재(TFC) 및 폴리술폰아미드(PSA) 막에 통합된 COF는 유기 오염물, 염 오염물 및 중금속 이온에 대한 거부 성능을 향상시켜 분리 능력을 향상시킵니다. TpPa-SO3H/PAN 공유 유기 프레임워크 막(COFM)은 대전된 그룹을 활용하여 정전기적 반발을 통해 효율적인 담수화를 가능하게 함으로써 기존의 폴리아미드 막에 비해 우수한 담수화 성능을 보여 이온 및 분자 분리의 잠재력을 제시했습니다. 이러한 연구 결과는 투과성, 선택성 및 안정성을 향상시켜 향상된 분리 공정을 위한 막 기술에서 COF의 잠재력을 강조합니다. 이 검토에서는 분리 공정에 적용된 COF에 대해 논의합니다.

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

SEPARATION OF CsCl FROM LiCl-CsCl MOLTEN SALT BY COLD FINGER MELT CRYSTALLIZATION

  • Versey, Joshua R.;Phongikaroon, Supathorn;Simpson, Michael F.
    • Nuclear Engineering and Technology
    • /
    • 제46권3호
    • /
    • pp.395-406
    • /
    • 2014
  • This study provides a fundamental understanding of a cold finger melt crystallization technique by exploring the heat and mass transfer processes of cold finger separation. A series of experiments were performed using a simplified LiCl-CsCl system by varying initial CsCl concentrations (1, 3, 5, and 7.5 wt%), cold finger cooling rates (7.4, 9.8, 12.3, and 14.9 L/min), and separation times (5, 10, 15, and 30 min). Results showed a potential recycling rate of 0.36 g/min with a purity of 0.33 wt% CsCl in LiCl. A CsCl concentrated drip formation was found to decrease crystal purity especially for smaller crystal formations. Dimensionless heat and mass transfer correlations showed that separation production is primarily influenced by convective transfer controlled by cooling gas flow rate, where correlations are more accurate for slower cooling gas flow rates.

Application of Membranes for Organic Liquid or Vapor Separation and Design of Plasma-Graft Filling-Polymerized Membranes

  • Yamaguchi, Takeo;Nakao, Shin-ichi
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 추계 총회 및 학술발표회
    • /
    • pp.34-39
    • /
    • 1996
  • There is much recent interests in applying membrane separation technologies, especially for organic liquid and vapor separation or removing dissolved organics from water. Pervaporation separation can separate azeotropic mixtures and mixtures close to boiling point, and it has a potential for energy saving process instead of distillation. Removal of chlorinated oraganics from water is other measure application for pervaporation separation. Contaminated pollutant must be removed from water, and a pervaporation can effectively remove the pollutant. Air pollution by organic vapor recently became serious enviromncntal problem, and removing organic vapor from air is important application of the membrane technology.

  • PDF