• Title/Summary/Keyword: Separation Point

Search Result 619, Processing Time 0.03 seconds

A CFD study on the Supersonic Flow through a Dual Bell Nozzle

  • Gopalapillai, Rajesh;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.324-330
    • /
    • 2012
  • Dual bell nozzle is one of the most promising choices among the altitude adaptation nozzles. This facilitates having a forced, steady and symmetrical separation at lower altitudes and a controlled flow separation at the wall inflection point which prevents the generation of dangerous side loads. In order to ensure the attached flow in the second bell, a clear understanding of the flow transition is required. Hence the motivation of our study is to arrive at an optimum profile for the second bell, which allows a sudden and controlled transition. In this work, we designed the first bell using the conventional MoC and the second bell using an inverse MoC, imposing a pressure gradient constraint. A CFD analysis is also carried out. It is found that the separation point is near the inflection point within one fourth of the extension length or it is near the exit.

  • PDF

Effects of the Free-Stream Turbulence and Surface Trip Wire on the Flow past a Sphere (자유류 난류와 표면 트립 와이어가 구 주위 유동에 미치는 영향)

  • Son, Kwang-Min;Choi, Jin;Jeon, Woo-Pyung;Choi, Hae-Cheon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.187-190
    • /
    • 2006
  • In the present study, effects of tree-stream turbulence and surface trip wire on the flow past a sphere at $Re\;=\;0.4\;{\times}\;10^5\;{\sim}\;2.8\;{\times}\;10^5$ are investigated through wind tunnel experiments. Various types of grids are installed upstream of the sphere in order to change the tree-stream turbulence intensity. In the case of surface trip wire, 0.5mm and 2mm trip wires are attached from $20^{\circ}\;{\sim}\;90^{\circ}$ at $10^{\circ}$ interval along the streamwise direction. To investigate the flow around a sphere, drag measurement using a load cell, surface-pressure measurement, surface visualization using oil-flow pattern and near-wall velocity measurement using an I-type hot-wire probe are conducted. In the variation of free-stream turbulence, the critical Reynolds number decreases and drag crisis occurs earlier with increasing turbulence intensity. With increasing Reynolds number, the laminar separation point moves downstream, but the reattachment point after laminar separation and the main separation point are fixed, resulting in constant drag coefficient at each free-stream turbulence intensity. At the supercritical regime, as Reynolds number is further increased, the separation bubble is regressed but the reattachment and the main separation points are fixed. In the case of surface trip wire directly disturbing the boundary layer flow, the critical Reynolds number decreases further with trip wire located more downstream. However, the drag coefficient after drag crisis remains constant irrespective of the trip location.

  • PDF

Control of the Sediment in a Combined Sewer Using a Separation Wall

  • Lim, Bong Su;Kwon, Chung Jin;Kim, Do Young;Lee, Kuang Chun
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.71-75
    • /
    • 2013
  • This study is to evaluate the effects of the separation wall on the sediment quality and quantity in a combined sewer, by surveying the sewer overflow and sediments during a rainfall. Since the separation wall installed in the combined sewer separates the rainfall and the sewage, the flow rate of the sewage is increased, and the amount of the sediment deposited on the sewer is decreased. One sampling point was the outfall of Daesacheon with a separation wall, and the other was the outfall of Gwaryecheon without a separation wall, in Daejeon metropolitan city. The maximum control of the biochemical oxygen demand (BOD) overflow load was more than 38% in the Daesacheon point with the separation wall, during a rainfall of 0.11 mm/hr. The maximum control of the BOD overflow load was 24% in Gwaryecheon without a separation wall, during a rainfall of 1.0 mm/hr. According to the survey results of the sediment in the sewer, the discharged sediment deposited on the sewer in Gwaryecheon point was about 23% to 28% of the total suspended solid during the rainfall. In addition, the average velocity of sewage in the presence of sediment was about 0.30 m/s, and if the separation wall is installed, it was expected to be about 1.01 m/s, that is 3.4 times more than the same conditions, resulting in the reduction of the sediment deposit.

An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구)

  • 황승식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

A Study on the Architectural Interpretation of the Korean Traditional Private Garden Pavilions from the perspective of Separation (구별적 관점에서 본 별서형정자의 건축적 해석에 관한 연구)

  • Kim, Jin-Su;Nam, Hae-Kyeong
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.3
    • /
    • pp.35-46
    • /
    • 2010
  • The purpose of this study is to interpretate the Korean traditional Private Garden Pavilion -'byoul-seo(別墅)' in the view point of the architectural methodology - the separation of space in Honam province. It is presumed that nature union is archived through the 'yan-sang(玩賞)' which is ultimate state of knowledge that is base on the premises of opened signification in emancipation from narrow view point in the past and cognition of value. therefore, it is needed to know the unworldly point of space perception about the pavilion territory, furthermore to have conceptual method to distinct pavilion from the world. there are two methods in the distinct concept in this pavilion research: unworldly separation and meditative separation. As a result, the followings are conclusions; There two distinctive methods of planning of pavilion by use of the room and column. There are enclosement, turnaround, division of floor area in the room organization method, and it's modification of modulation, diversification of column height and diversification of column use in different space.

A PRACTICAL METHOD FOR THE DISPOSAL OF RADIOACTIVE ORGANIC WASTE

  • Kim, Kil-Jeong;Shon, Jong-Sik;Ryu, Woo-Seog
    • Nuclear Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.731-736
    • /
    • 2007
  • Radioactive organic wastes containing acetone, alcohol, and particularly tributyl phosphate (TBP)/dodecane contaminated with uranium are extracted from the PUREX process and the decontamination of related equipment. An evaporation method that utilizes existing DU oxidation apparatuses and ventilation systems and a typical muffle furnace installed with an aspirating system are adopted. A separation method using phosphoric acid especially for the TBP/dodecane waste is also studied and evaluated. The results show that a simple evaporation process is utilizable for wastes containing acetone or alcohol with a lower boiling point. A modified muffle furnace is more appropriate to dispose directly of organic wastes having a higher boiling point, such as TBP/dodecane, without generating a condensed waste solution. It is recommended that, when the uranium concentration of TBP/dodecane waste is much higher than stipulated levels, separation technology should be applied to remove uranium from the mixture. Each type of solvent after separation can then be considered disposable below the regulatory limit in the modified furnace discussed in this study.

Discrete Vortex Simulation of Turbulent Separated and Reattaching Flow With Local Perturbation (국소교란이 있는 난류박리 재부착유동의 이산와류 수치해석)

  • 정용만;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.479-491
    • /
    • 1994
  • Discrete vortex method was applied for simulating an active control of turbulent leading- edge separation bubble. The leading-edge separation zone was perturbed by a time-dependent sinusoidal perturbation of different frequencies and levels. In order to describe the local sinusoidal perturbation at the separation point, a source pulsation vortex technique was proposed. The present two-dimensional vortex simulations were qualitatively compared with the experimental results for a blunt circular cylinder, where perturbation was introduced along the square-cut leading edge of the cylinder $(Kiya et al.^{(6,7)}).$ It was found that the reattachment length attained a minimum point at low levels of perturbation and two minima at a moderate higher perturbation frequency. The effects of local perturbation on the evolution of leading-edge separation bubble were scrutinized by comparing the perturbed flow with the natural flow. These comparisons were made for the distributions of mean velocity and its velocity fluctuations, intermittency and wall velocity. The motions of instantaneous reattachment in the space-time domain were demonstrated, which were also compared with the experimental findings. In order to investigate the reduction mehanism of reattachment length in the separation bubble, various cross-correlations for velocity and pressure and the relevant convection velocities were evaluated. It was observed that the convection velocity was closely associated with its corresponding pulsationg frequency.

Measurement of Multi Conflict Avoidance for Free flight Efficiency (자유비행 다중 충돌회피 효율성 측정 연구)

  • Lee, Dae-Yong;Kang, Ja-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • In this paper, study the substantial issues which occurs upon free flight environment by performing separation assurance under multiple conflict(over 3 Aircraft), recovery en route under the terms of time constrains and fixed way point after the conflict avoidance, correlations between conflict detection distance and separation assurance by utilizing Autonomous flight algorithm. Result of this experiment demonstrates that the extension of detection distance is advantageous to solution of separation assurance and enhancing of flight efficiency, choose to maneuver by applying time constrain terms and fixed way point according to the situation of conflict prediction in case of recovery maneuver after the conflict avoidance. And separation assurance can be solved by applying 2 degrees or more of bank angle. When choosing the optimal bank angle could be drastically improved flight efficiency.

A Study on the Characteristics of Multi-point Pilot Tube Flow-meter (다점 피토관 유량계의 특성에 관한 연구)

  • 임재명;윤복현;박경암
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.2 s.11
    • /
    • pp.35-43
    • /
    • 2001
  • The flow characteristics passing a multi-point Pitot tube flow-meter of diamond shape and the characteristics of flow coefficients of the flow-meter are experimentally studied by varying combination of upstream rectangular dual elbows. The results provide the flow coefficients, which show good stability and reliability within the Reynolds number range coveted here in this study, and which can be used to measure flow-rates in practice. The variation of dual elbows upstream can change the velocity field so much that the flow pattern might thwart the precise flow measurement using the multi-point Pitot tube. The strongest swirl is detected in the case of $90^{\circ}$ dual elbow combination of all. In addition, it is observed that flow separation remains unchanged and occurs at the same point irrespective of various upstream dual elbow combinations.

  • PDF