• Title/Summary/Keyword: Separation Line

Search Result 386, Processing Time 0.028 seconds

Protection Distance Calculation Between Inductive Systems and Radiocommunication Services Using Frequency Below 30 MHz (30 MHz 이하에서 무선 서비스와 유도성 시스템 간의 보호 거리 산출)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Park, Seung-Keun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1211-1221
    • /
    • 2012
  • This paper describes separation distance to protect radiocommunication services from the interference of inductive systems using frequencies below 30 MHz for the co-existence between radiocommunication services and inductive systems. For the analysis, the interference scenario model is proposed between inductive system and radiocommunication services. Then the calculation method of protection distance is suggested by comparing the radiation power of inductive system with the allowable interference level of victim services, radiocommunication services, according to the applied propagation model. Also, the protection distance for protecting radiocommunication services in the 30 MHz below is calculated through the interference analysis from RFID(Radio Frequency IDentification) and PDP(Plasma Display Panel) TV based on the suggested method. The proposed calculation method was adopted as ITU-R recommendation in related with resolution 63 at ITU-R SG(Study Group) 1 meeting in June, 2012. It will be available to use for the protection of radiocommunication services from the interference of wireless power transfer system and power line telecommunication system.

A cell scheduling of a logically separated buffer in ATM switch (ATM 스위치에서 논리적으로 분할된 버퍼의 셀 스케쥴링)

  • 구창회;나지하;박권철;박광채
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.8
    • /
    • pp.1755-1764
    • /
    • 1997
  • In this paper, we proposed the mechanism for the buffer allocation and a cell scheduling method with logical separation a single buffer in the ATm switch, and analyzed the cell loss probability and the delay of each trafic (CBR/VBR/ABR) based on the weighted value and the dynamic cell service scheduling algorithm. The proposed switch buffering system classifies composite trafics incoming to the switch, according to the characteristic of traffic, then stores them in the logically separated buffers, and adopts the round-robin service with weighted value in order to transmit cells in buffers though one output port. We analyzed 4 cell service scheduling algorithms with dynamic round-robinfor each logically separated service line of a single buffer, in which buffers have the respective weighted values and 3 classes on mixed traffic which characteristized by traffic descriptor. In simulation, using SIMCRIPT II.5., we model the VBR and the ABR traffics as ON/OFF processes, and the CBR traffic as a Poisson processes. As the results of analysis according to the proposed buffer management mechanism and cell service algorithm, we have found that the required QoS of each VC can be quaranteed depends on a scale of weighted values allocated to buffers that changed the weighted values, and cell scheduling algorithm.

  • PDF

A Watermarking for Text Document Images using Edge Direction Histograms (에지 방향 히스토그램을 이용한 텍스트 문서 영상의 워터마킹)

  • 김영원;오일석
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.2
    • /
    • pp.203-212
    • /
    • 2004
  • The watermarking is a method to achieve the copyright protection of multimedia contents. Among several media, the left documents show very peculiar properties: block/line/word patterning, clear separation between foreground and background areas. So algorithms specific to the text documents are required that meet those properties. This paper proposes a novel watermarking algorithm for the grayscale text document images. The algorithm inserts the watermark signals through the edge direction histograms. A concept of sub-image consistency is developed that the sub-images have similar shapes in terms of edge direction histograms. Using Korean, Chinese, and English document images, the concept is evaluated and proven to be valid over a wide range of document images. To insert watermark signals, the edge direction histogram is modified slightly. The experiments were performed on various document images and the algorithm was evaluated in terms of imperceptibility and robustness.

Removal of Unburned Carbon from Fly Ash using Countercurrent Column Flotation Cell (역류형 컬럼 부선기를 이용한 석탄회정제에 관한 연구)

  • 이전언;이제군
    • Resources Recycling
    • /
    • v.8 no.5
    • /
    • pp.51-58
    • /
    • 1999
  • The sbdy iwestlgaled ihc propa-ties of Lhe dust\ulcorner rrom fe~~oallomya ~~ufacturTeh. e chemical composition, cornpasitlon material, p d c l e sire md shapes of the bulk dust, sired dust and magnetically separated durl were mvesligaled. As the re\ulcornerulL, we suppose that the dust from &gh Carbon Fenama~~gunesMc anuiact~vingP rocess is not sufiicient as solulce material of Mn because of ale low Mn canlenl (13.5%) and complicaled composition mate~ial. The dust from Bug F!lter or AOD Proccss is mi~inlym ade up of 0.2-2 pm Mn30, (Hausmam~iu)p iutlde in spherical shape and thc Mn content is 63.190.The dust from Cooler of AOD Process is inninly made up of coarse Ca(O1-Or)zM. n,FeyO,, SiO, and fine Mn30d.

  • PDF

A Study on th Quality Stabilization of Iron Oxide (산화철의 품질 안정화)

  • 변태봉;한기현;김형석;배우현
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.55-63
    • /
    • 1998
  • The main purpose of the present study is to reduce quality variation of iron oxide for soft ferrite produced at hydrochloric acid facility )HAF) in a cold rolled mill factory. We investigated the factor of iron oxide quality variation, the operating condition of hydrochloric acid facility and the iron oxide quality with the production lot. Based on this information, we liad developed proper working plan for the diminution of iron oxide quality variation. To reduce iron oxide quality variation, the first priority is to control the picking steels, which seriously affect iron oxide quality variation, and then to separate generated waste acid. theretore, it was possible to reduce iron oxide quality variation with the proper operation of various kinds of waste acid tanks. We could produce iron oxide below 20 ppm SiO$_{2}$ content variation by operation after separation waste acid generated at TCM line.

  • PDF

An Analysis of Voltage Characteristics for LC Resonant Frequency Band of Capacitor Compensation According to Moving of Electrical Separation Equipment of AF Track Circuit (AF궤도회로의 전기적 구분 장치 설치이전에 따른 커패시터 보상으로 LC공진 주파수 대역의 전압특성 분석)

  • Won, Seo-Yeon;Choi, Jae-Sik;Park, Hun-Jue;Kim, Hie-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1466-1477
    • /
    • 2016
  • This paper analyzes the electrical characteristic such as the impedance(Z), inductance(L), and cable resistance($R_p$) according to the change of cable length in order to move the electrical sorting device for distinguishing between AF non-insulated track circuits from the center of railway to outside railway. The simulation is performed to check the voltage difference between the voltage of sender and the voltage of receiver and determine the possibility of the voltage restoration availability in the frequency filter band through the capacitor compensation. It was applied to the results of the simulation to the sorting devices installed in the actual field. It is proved the availability by checking the measured voltage characteristic according to the capacitor compensating change of $10{\mu}F$ and $16{\mu}F$ before, and after the length of cable is increased with 6 meters. Through this, the prevention of breakdown and damage to facilities and the prevention the safety-related accidents of line workers from the train are expected according to moving the sorting devices of AR non-insulated track circuits to outside railway.

Stability Analysis of Concrete Plugs Installed in Pilot Tunnels for the Storage of Compressed Air (압축공기 저장용 파일롯 터널에 설치된 콘크리트 플러그의 안정성 해석)

  • Lee, Youn-Kyou;Song, Won-Kyoung;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.446-454
    • /
    • 2010
  • CAES-G/T (Compressed Air Energy Storage - Gas Turbine) power generation is a likely option for the buffer facility stabilizing the fluctuation of the renewable powers, such as wind and solar powers. Considering the geological conditions, the underground CAES facility is most probable if the CAES-G/T generation is planed in Korea. In this kind of facility, a concrete plug is installed to seal the compressed air in the container, so that the selection of the shape and dimension of concrete plug could be a critical design factor. The stability evaluation of two types of plug was carried out by investigating the distribution of the factor of safety in the plugs and the distribution of contact pressure over the contact surface. The analysis result shows that the taper-shaped plug is more structurally stable than the wedge-shaped plug for the given geological condition. Possible separation of the rock-concrete interface around the spring line of the wedge-shaped plug is anticipated, which means the possible leakage of compressed air through the side wall and also means the poor mobilization of frictional resistance on that area.

An Experimental Study of Flow and Dispersion Characteristics in Meandering Channel (사행수로에서의 유속 및 분산특성에 관한 실험적 연구)

  • Park, Sung-Won;Seo, Il-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.799-802
    • /
    • 2008
  • General behaviors based on hydraulic characteristics of natural streams and channels have been recently analyzed and developed via various numerical models. However in the states of natural hydraulics, an experimental research must be performed simultaneously with the mathematical analysis due to effects of hydraulic properties such as meander, sediment, and so on. In this study based on 2-D advection-dispersion equation, flow and tracer experiments were performed in the S-curved meandering laboratory channel with a rectangular cross-section. The channel was equipped with instrument carriages which was equipped with an auto-traversing system to be used with velocity measuring sensors throughout the depth and breadth of the flow field. To measure concentration distribution of the salt solution was adjusted to that of the flume water by adding methanol and a red dye (KMnO4) was added to aid the visualization of the tracer cloud, the tracer was instantaneously injected into the flow as a full-depth vertical line source by the instantaneous injector and the initial concentration of the tracer was 100,000 mg/l. The secondary current as well as the primary flow pattern was analyzed to investigate the flow distribution in the meandering channels. The velocity distribution of the primary flow for all cases skewed toward the inner bank at the first bend, and was almost symmetric at the crossovers, and then shifted toward the inner bank again at the next alternating bend. Thus, one can clearly notice that the maximum velocity occurs taking the shortest course along the channel, irrespective of the flow conditions. The result of the tracer tests shows that pollutant clouds are spreading following the maximum velocity lines in each cases with various mixing patterns like superposition, separation, and stagnation of pollutant clouds. Flow characteristics in each cases performed in this study can be compared with tracer dispersion characteristics with using evaluation of longitudinal and transverse dispersion coefficients(LDC, TDC). As expected, LDC and TDC in meandering parts have been evaluated with increasing distribution and straight parts have effected to evaluate minimum of LDC and TDC due to symmetric flow patterns and attenuations of secondary flow.

  • PDF

Design Methodology of Communication & Control Device for Smart Grid Power Facility based on DSP and Raspberry Pi (DSP와 라즈베리 파이를 기반으로 한 스마트 그리드 전력설비의 통신제어장치 설계 방법론)

  • Oh, Se-Young;Lee, Jun-Hyeok;Lee, Sae-In;Park, Chang-Su;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.835-844
    • /
    • 2021
  • In this paper, a power facility communication control device was designed to autonomously determine and separate the fault section through communication between power facilities in the smart grid distribution system. In the power facility communication control device, the control module was designed as a DSP to measure three-phase voltage and current, and the communication module was designed as an embedded-based Raspberry Pi to determine the fault section and realize the fault section separation through communication between power facilities. Communication between DSP and Raspberry Pi was designed by SPI communication, and communication between Raspberry Pi was designed based on Wi-Fi. Finally, a performance evaluation system based on three power facility communication control devices was built, and simulation verification was conducted for various fault events that may occur on the distribution line. As a result of the test evaluation, it was possible to confirm the effectiveness of the design methodology of the communication control device by showing the required response of the communication control device to all test cases.

OGLE-2017-BLG-1049: ANOTHER GIANT PLANET MICROLENSING EVENT

  • Kim, Yun Hak;Chung, Sun-Ju;Udalski, A.;Bond, Ian A.;Jung, Youn Kil;Gould, Andrew;Albrow, Michael D.;Han, Cheongho;Hwang, Kyu-Ha;Ryu, Yoon-Hyun;Shin, In-Gu;Shvartzvald, Yossi;Yee, Jennifer C.;Zang, Weicheng;Cha, Sang-Mok;Kim, Dong-Jin;Kim, Hyoun-Woo;Kim, Seung-Lee;Lee, Chung-Uk;Lee, Dong-Joo
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.6
    • /
    • pp.161-168
    • /
    • 2020
  • We report the discovery of a giant exoplanet in the microlensing event OGLE-2017-BLG-1049, with a planet-host star mass ratio of q = 9.53 ± 0.39 × 10-3 and a caustic crossing feature in Korea Microlensing Telescope Network (KMTNet) observations. The caustic crossing feature yields an angular Einstein radius of θE = 0.52 ± 0.11 mas. However, the microlens parallax is not measured because the time scale of the event, tE ≃ 29 days, is too short. Thus, we perform a Bayesian analysis to estimate physical quantities of the lens system. We find that the lens system has a star with mass Mh = 0.55+0.36-0.29 M⊙ hosting a giant planet with Mp = 5.53+3.62-2.87 MJup, at a distance of DL = 5.67+1.11-1.52 kpc. The projected star-planet separation is a⊥ = 3.92+1.10-1.32 au. This means that the planet is located beyond the snow line of the host. The relative lens-source proper motion is μrel ~ 7 mas yr-1, thus the lens and source will be separated from each other within 10 years. After this, it will be possible to measure the flux of the host star with 30 meter class telescopes and to determine its mass.