• Title/Summary/Keyword: Separation Force

Search Result 441, Processing Time 0.031 seconds

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Quest for Yeoheon Jang Hyeon-gwang's View on Education - Deepening of the intrinsic nature in accordance with the Neo-Confucianistic thought (여헌(旅軒) 장현광(張顯光)의 교육관 탐구 - 성리학적 본질의 심화 -)

  • Shin, Chang-ho
    • (The)Study of the Eastern Classic
    • /
    • no.33
    • /
    • pp.31-56
    • /
    • 2008
  • Jang Hyeon-gwang(張顯光, 1554-1637), whose pseudonym or courtesy name is 'Yeoheon(旅軒)', had made a thorough study on the intrinsic nature of Neo-Confucianism in a more sincere fashion, when comparing him with other Neo-Confucianists in Joseon period. Also he was a renowned scholar who expanded its philosophical system in-depth. Yeoheon thereby had strengthened his philosophical system accordant with the Great Learning(大學) and Doctrine of the Mean(中庸), which are the fundamental systems of Neo-Confucianistic education. Based on such considerations, Yeoheon's thought on education can be illuminated from three different perspectives. First, Yeoheon deepened his a theory of good governance by a virtuous ruler(聖人君主論, pronounced, 'Seongingunjuron') as the standard of education. Essentially, his theory pursues Refraining from desire, and preserving the laws of nature(存天理?人欲, pronounced, 'Joncheolliarinnyok'), and put emphasis on ethical awakening, and the governance through a virtue of moral excellence. Second, Yeoheon stressed the learning theories related to 'sincerity' or true heart(誠) and 'piety' or 'respect'(敬)) as the form of education(誠敬, pronounced, 'Seonggyeong'). Also he expounded that people needs "to establish a ground of Respect and Sincerity in their mind." He recognized the differences between the two virtues, meanwhile, however, he understood it as in an identical context. Third, Yeoheon advocated harmony between separation and integration(分合, pronounced, 'Bunhap') as a method for education. Through his unique 'Discourse on Longitude and Latitude', dubbed, 'Li-Gi Gyeongwiseol (理氣經緯說) in which the principle(Li, 理) is equal to the intrinsic energy or material force(Gi, 氣), he maintained his view on the Doctrine of the Mean, in that he was not inclined to either sides according to the logic of Change(易, pronounced 'Yeok'). When reviewing Yeoheon's contemplation in education in the meaning of modern education, he laid the standards for education on the establishment of morality, and he also provides us with an idea which induces us to look through the form and method for education from the perspective of Doctrine of the Mean. In short, Yeoheon's view on education embodies wisdom of traditional Neo-Confucianistic Education having consistency, and it provides for an implication of the review of the importance of the balance in relation to methodological bias toward confusion in the standards for modern education, and unsystematic contents therein.

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF

Exhaust Plume Behavior Study of MMH-NTO Bipropellant Thruster (MMH-NTO 이원추진제 추력기의 배기가스 거동 해석 연구)

  • Kim, Hyeonah;Lee, Kyun Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.4
    • /
    • pp.300-309
    • /
    • 2017
  • A spacecraft obtains a reaction momentum required for an orbit correction and an attitude control by exhausting a combustion gas through a small thruster in space. If the exhaust plume collides with spacecraft surfaces, it is very important to predict the exhaust plume behavior of the thruster when designing a satellite, because a generated disturbance force/torque, a heat load and a surface contamination can yield a life shortening and a reduction of the spacecraft function. The purpose of the present study is to ensure the core technology required for the spacecraft design by analyzing numerically the exhaust gas behavior of the 10 N class bipropellant thruster for an attitude control of the spacecraft. To do this, calculation results of chemical equilibrium reaction between a MMH for fuel and a NTO for oxidizer, and continuum region of the nozzle inside are implemented as inlet conditions of the DSMC method for the exhaust plume analysis. From these results, it is possible to predict a nonequilibrium expansion such as a species separation and a backflow in the vicinity of the bipropellant thruster nozzle.

Explicit Nonlinear Finite Element Analysis for Flexural/Shear Behavior of Perfobond FRP-Concrete Composite Beam (퍼포본드 FRP-콘크리트 합성보의 휨/전단거동에 관한 외연적 비선형 유한요소해석 연구)

  • Yoo, Seung-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.771-776
    • /
    • 2020
  • In this study, the flexural/shear behavior characteristics of perfobond FRP-concrete composite beams using an FRP plate with perforated webs as formwork and reinforcement are analyzed through an analytical method. Compared with the existing experimental results, we have proved its usefulness and use it in future practice. When the nonlinearity is very large in this case, the nonlinear finite element analysis by an explicit method will be effective. The concrete damage plasticity (CDP) model adopted in this study is considered to be able to adequately simulate the nonlinear behavior of concrete, and the determination of several variable factors required in the model is compared with the experimental results and values used in the study. This recommendation will require review and adjustment for more diverse cases. The effect of the perfobond of the composite beam with perforated web is considered to be somewhat effective in terms of securing the initial stiffness, but in the case of the apex, it is considered that the cross-sectional loss and the effect of improving the bonding force should be properly arranged. The contact problem, such as slipping of the FRP plate and concrete, is considered to be one of the reasons that the initial stiffness is slightly larger than the test result, and the slightly difference from the experimental results is attributed to the separation problem between concrete and FRP after the peak.

Structural Analysis of a Suction Pad for a Removable Bike Carrier using Computational and Experimental Methods (탈착식 자전거 캐리어용 흡착 패드의 실험 및 전산적 방법을 활용한 구조해석)

  • Suh, Yeong Sung;Lim, Geun Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.622-628
    • /
    • 2016
  • As the suction pad-supporting bike carrier attached to a car may be subject to an excessive dynamic load due to random vibrations and centrifugal forces during driving, its structural safety is of great concern. To examine this, the finite-element method with a fluid-structure interaction should be used because the pressure on the pad bottom is changed in real time according to the fluctuations of the force or the moment applied on the pad. This method, however, has high computing costs in terms of modeling efforts and software expense. Moreover, the accuracy of computation is not easily guaranteed. Therefore, a new method combining the experiment and computation is proposed in this paper: the bottom pressure and contact area of the pad under varying loads was measured in real time and the acquired data are then used in the nonlinear elastic finite-element calculations. The computational and experimental results obtained with the product under development showed that the safety margin of the pad under the axial loading is relatively sufficient, whereas with an excessive rotational loading, the pad is vulnerable to separation or a local surface damage; hence, the safety margin may not be secured. The predicted contact behavior under the variation of the magnitude and type of the loading were in good agreement with the one from the experiment. The proposed analysis method in this study could be used in the design of similar vacuum pad systems.

EXPRESSION OF TGF-${\beta}1$, OSTEONECTIN AND BMP-4 ON BONE REGENERATION IN MANDIBULAR DISTRACTION OSTEOGENESIS COMBINATION WITH A COMPRESSION STIMULATION (하악골 신장술에서 압축자극을 통한 골재생시 TGF-${\beta}1$, Osteonectin 및 BMP-4의 발현)

  • Park, Seong-Jin;Kim, Uk-Kyu;Chung, In-Kyo;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Cheol-Hoon;Byun, June-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.288-296
    • /
    • 2007
  • Distraction osteogenesis(DO) is a technique of lengthning bone including soft tissue by gradual separation of surgically divided bone surfaces. Distraction osteogenesis combination with a compression stimulation(DO-CO) was a new technique by authors to enhance new bone quality and to shorten the consolidation period. The purpose of this study was to compare DO with DO combined with compression force in efficiency by evaluating the expression of TGF-${\beta}1$, osteonectin and BMP-4 on bone regenerate in rabbit mandible. Fourty two rabbits were used for this experiment. On the control group, the distraction was carried out at the rate of 1 mm per day to obtain the amount of 8 mm distraction for 8 days. On the experimental group, the distraction was carried out at the rate of 1 mm per day for 10 days, 3 days-latency period, and then the compression was carried out as counter direction 1 mm per day for 2 days. After 0 day, 5 days, 13 days, 20 days, 27 days, 34 days and 41 days, three rabbits on each group were sacrificed and the distracted portion of mandible were cut and treated for RT-PCR observation. The level of expression of TGF-${\beta}1$ and osteonectin were shown more and longer expression in the experimental group than in the control group. The expression of BMP-4 was maintained with high level during the entire experimental period in both groups. These findings suggested that DO with compression stimulation could be a favorable technique for obtaining a good new bone quality.

The Effect of Ion Water and Premixed Mineral Supplementation on the Growth Performance, Carcass, and Meat Quality Parameters in Finishing Pigs (이온수 및 복합광물질첨가 비육돈의 생산형질, 도체 및 육질 특성에 미치는 영향)

  • Jin, Sang-Keun;Kim, Il-Suk;Song, Young-Min;Kang, Suk-Nam;Jong, Je-Yun;Oh, Hee-Suk;Min, Chan-Sick
    • Food Science of Animal Resources
    • /
    • v.29 no.2
    • /
    • pp.252-259
    • /
    • 2009
  • This study investigated the effects of ion water and premixed mineral supplementation on the growth performance, carcass, and meat quality parameters in finishing pigs ($LY{\times}D$). Each 20 pigs were randomly allotted to three treatments; CON (basal diet), T1(CON diet added with active water), T2 (T1 diet added with 1.0% premixed mineral). Used ion water and premixed mineral were consisted mainly of Zn and Si, respectively. Daily weight gain feed efficacy were the highest in T2, while fat content was the highest in control (p<0.05) than the others. However, the slaughter qualities including dressing percent, backfat thickness, marbling score, meat color, meat texture, drip loss, meat separation and meat qualities including pH, cooking loss, water holding capacity (WHC), shear force, meat color, backfat color, meat texture were not significantly different (p>0.05) among the treatment groups. Panel test scores of tenderness were the highest in T2 compared to the others.

Applicability of Washing Techniques Coupled with High-Pressure Air Jet for Petroleum-contaminated Soils (고압공기분사를 이용한 유류오염토양 세척기법의 적용성 연구)

  • Choi, Sang-Il;Kim, Kang-Hong
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.61-68
    • /
    • 2006
  • Soil washing techniques coupled with high pressure air jet were applied for diesel-contaminated soils sampled by an underground oil reservoir of which the initial total petroleum hydrocarbon (TPH) ($2,828{\pm}206\;mg/kg$) exceeded 5 times of current standard level (500 mg/kg) regulated by the Soil-Environment Conservation Law. Through several tests, we found that the position of impeller has a critical impact for washing efficiencies. The highest washing efficiency was obtained at an oblique angle (30 degree) for the impeller and optimized mixing speed (300 rpm) that could have high shearing forces. Considered economical and feasible aspects, the optimum mixing time was 10 min. Rate constants of TPH removal derived from the first-order equation were not linearly increased as mixing speed increased, indicating that mechanical mixing has some limits to enhance the washing efficiencies. Application of high-pressure air jet in washing process increased the washing efficiency. This increase might be caused by the fact that the surface of micro-air bubbles strongly attached hydrophobic matters of soil particles. As the pressure of air jet increased, the separation efficiencies of TPH-contaminated soil particles increased. In the combined process of high-pressure air jet and mixing by impeller, the optimum mixing speed and air flow-rate were determined to be 60 rpm and $2\;kg/cm^2$, respectively. Consequently, the washing technique coupled with high-pressure air jet could be considered as a feasible application for remediating petroleum-contaminated soils.

Analysis of the Micro-Structural and Mechanical Properties in Human Femoral Head Trabecular Bone with and without Osteoporosis (대퇴골두 해면골의 미세구조 특성과 기계적 특성의 분석)

  • Won Ye-Yeon;Baek Myong-Hyun;Cui WenQuan;Chun KeyoungJin;Kim Man Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.519-523
    • /
    • 2004
  • This study investigates micro-structural and mechanical properties of trabecular bone in human femoral head with and without osteoporosis using Micro-CT and finite element-model. 15 cored trabecular bone specimens with 20min of diameter were obtained from femoral heads with osteoporosis (T-score > -2.5 ) resected for total hip arthroplasty, and 5 specimens were removed from femoral head of cadavers, which has no history of musculoskeletal diseases. A high-resolution micro-CT system was used to scan each specimen to obtain histomorphometry indices. Based on obtained micro-images(pixel size=21.31㎛), a FE-model was created to determine mechanical property indices. While non-osteoporosis group had increases trabecular thickness, bone volume, bone volume fraction, degree of anisotropy and trabecular number compared with those of non-osteoporotic group, the non-osteoporotic group showed decreases in trabecular separation and structure model index. Regarding the mechanical property indices, reaction force, apparent stress and young's modulus were 1ower in osteoporotic group than in non-osteoporotic group. Our data shows salient deteriorations in trabecular micro-structural and mechanical properties in human femoral head with osteoporosis.