• Title/Summary/Keyword: Seoul City Hall Subway Station

Search Result 2, Processing Time 0.017 seconds

Concentration of Sulfur dioxide ($SO_2$) of Subway Stations in Seoul (서울지역 지하철역 구내의 아황산가스 농도)

  • 손부순;장봉기
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 1999
  • This study was performed to survey the $SO_2$ level at several underground spaces connected to 5 subway stations (City Hall, Nam, Seoul stations, Hye Hwa and Ulchiro 1 Ga) in Seoul. The period of survey was from July to November, 1997.The results of the study were as follows; 1. The mean concentration of $SO_2$ was $0.057{\pm}0.015ppm$ in all subway stations. The highest $SO_2$ level among the five stations was $0.067{\pm}0.011 ppm$ at City Hall (P<0.01), and the highest with $0.071{\pm}0.013ppm$ at November (P<0.01).2. In underground shopping centers, the mean concentration of $SO_2$ was $0.112{\pm}0.059ppm$. 3. The mean concentration of $SO_2$ at evening with 0.057 pp and morning with 0.053 ppm were significantly higher than at noon with 0.043 ppm(P<0.05). 4. The $SO_2$ level of floor at Kang Nam station with 0.044 ppm was significantly higher than that of platform with 0.37 ppm(P<0.01). 5. For the City Hall stations, the line #1 and line #2 subway spaces show significantly different level of $SO_2$, 0.042ppm and 0.033 ppm respectively (P<0.05).

  • PDF

A Study on the Construction of Indoor Spatial Information using a Terrestrial LiDAR (지상라이다를 이용한 지하철 역사의 3D 실내공간정보 구축방안 연구)

  • Go, Jong Sik;Jeong, In Hun;Shin, Han Sup;Choi, Yun Soo;Cho, Seong Kil
    • Spatial Information Research
    • /
    • v.21 no.3
    • /
    • pp.89-101
    • /
    • 2013
  • Recently, importance of indoor space is on the rise, as larger and more complex buildings are taking place due to development of building technology. Accordingly, range of the target area of spatial information service is rapidly expanding from outdoor space to indoor space. Various demands for indoor spatial information are expected to be created in the future through development of high technologies such as IT Mobile and convergence with various area. Thus this research takes a look at available methods for building indoor spatial information and then builds high accuracy three-dimensional indoor spatial information using indoor high accuracy laser survey and 3D vector process technique. The accuracy of built 3D indoor model is evaluated by overlap analysis method refer to a digital map, and the result showed that it could guarantee its positional accuracy within 0.04m on the x-axis, 0.06m on the y-axis. This result could be used as a fundamental data for building indoor spatial data and for integrated use of indoor and outdoor spatial information.