Fermentation Characteristics of Yakju Added with Acanthopanacis cortex Extract (오가피 추출액 첨가 약주의 발효특성)

  • Kim, In-Ho;Kim, Seong-Ho;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.4
    • /
    • pp.521-527
    • /
    • 2008
  • Acanthopanacis cortex extracts added Yakju was manufactured and then fermentation and quality characteristics of Yakju were examined. Acanthopanacis cortex extracts added Yakju showed totally similar characteristics with the non-extract added Yakju of control groups. The pH showed almost no change to pH 4.0 after 6 days of fermentation and it was decreased only once in only fermentation time of 3 days. The acidity of Acanthopanacis cortex extracts added group showed no difference to the control group. The sugar obrix and reducing sugar content showed decrease in all two groups in the initial fermentation stage; however, it showed slow decrease as the late fermentation stage. The Acanthopanacis cortex extracts added Yakju showed less alcohol content than the control group in the initial fermentation stage. However, after 6 days of fermentation, the Acanthopanacis cortex extracts added Yakju showed more alcohol contents and constant increase till the final fermentation day. The pH, acidity, reducing sugar and alcohol content showed rapid changes between fermentation days 0 through 3. Therefore, it means that the Acanthopanacis cortex extracts added Yakju fermentation actively takes place between the days 0 through 3. Organic acids detected in Yakju were acetic, lactic, oxalic, malic and succinic acids. The acetic acid was the highest among the total acid contents. Eleutheroside E and chlorogenic acid, known as the effective components of Acanthopanacis cortex, showed stable status without changes in component content till stage two fermentation. The contents of eleutheroside E and chlorogenic acid were $7.61\pm0.39{\mu}g/mL$ and $3.63\pm0.18{\mu}g/mL$ on the final fermentation day, respectively. The fusel oil was slightly detected in both groups with values of $0.08\pm0.001{\sim}0.86\pm0.03mg%$ in n-propyl alcohol, isobutyl alcohol and isoamyl alcohol content. The Acanthopanacis cortex extracts added group was similar to the control group in the overall sensory test.

Physiological and Proteomic Responses of Barley Seedlings to Salt Stress (보리의 생육초기 염 스트레스에 따른 생리적 반응과 프로테옴 변화)

  • Kim, Dea-Wook;Yun, Seong-Kun;Park, Hyoung-Ho;Hwang, Jong-Jin;Han, Ok-Kyu;Park, Tae-Il;Jung, Gun-Ho;Lee, Jae-Eun;Kim, Sun-Lim;Chung, Young-Ho
    • Journal of the Korean Society of International Agriculture
    • /
    • v.23 no.5
    • /
    • pp.537-545
    • /
    • 2011
  • This study was conducted to obtain basic information on physiological and proteomic responses of barley seedlings to salt stress. Shoot dry weight decreased significantly as the level of soil salinity increased. Salt stress-induced decrease of relative shoot dry weight was lower in cv. "Sanglok" than in cv. "Sunwoo". Under the salt stress, SPAD value decreased, and the value was higher in cv. "Sanglok" than in cv. "Sunwoo". Sodium ion content in the leaves increased as NaCl concentration increased, and the content was higher in cv. "Sunwoo" than in cv. "Sanglok". The K+/Na+ ratio was higher in cv. "Sanglok" than in cv. "Sunwoo". Salt stress-induced alterations in protein expression of the leaves were detected by two dimensional electrophoresis, and 47 protein spots showing altered expression were selected. Among the selected protein spots, 17 protein spots were up-regulated and 28 spots down-regulated in cv. "Sanglok". In cv. "Sunwoo", 14 protein spots were up-regulated and 27 spots down-regulated. Out of 47 deferentially expressed protein spots, 18 protein spots were identified using mass spectrometry and NCBI protein database. Among the identified proteins, ten proteins are known to be involved in various stress responses, but the others are not directly involved in stress responses.

Immuno-regulatory Activities of Various Fractions from Ehpedrae Sinica STAPF, Rubus Coreanus Miq. and Angelica gigas Nakai Extracts with Ultrasonification (초음파 병행 추출을 이용한 마황과 복분자, 당귀 분획물의 면역활성 조절 효과)

  • Kim, Jung-Hwa;Kim, Dae-Ho;You, Jin-Hyun;Kim, Cheol-Hee;Kwon, Min-Chul;Seong, Nak-Sul;Lee, Seung-Eun;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.13 no.4
    • /
    • pp.161-170
    • /
    • 2005
  • This study was performed to examine immuno-regulatory activities of Ehpedrae Sinica STAPF, Rubus Coreanus Miq. and Angelica gigas Nakai extracts in conbination with ultrasonification. The extract yields of plants were the highest in the extraction system of $60^{\circ}C$ and 40 kHz of ultrasonification. The immune cell growth ratio of human immune B and T cells was increased compared to other fractions by the water fraction of the plants at $60^{\circ}C$ and 40 kHz. The water fractions of the plants at $60^{\circ}C$ and 40 kHz increased the specific secretion of IL-6 and $TNF-{\alpha}$ of human immune B and T cells compared to other fractions of the plants. The water fraction of Ehpedrae Sinica STAPF among the plants was observed to show the highest specific secretion of IL-6 and $TNF-{\alpha}$. Also, NK-92 MI cells growth was increased in adding the water fractions of the plants at $60^{\circ}C$ and 40 kHz. The water fraction of Ehpedrae Sinica STAPF among the plants showed the highest in NK-92 MI cell growth ratio. The differentiation activity of the HL-60 cells significantly increased in adding the water fraction of Ehpedrae Sinica STAPF compared to other fractions of the plants. These results suggest that the water fractions of the plants in extraction system of temperature $60^{\circ}C$ and ultrasonification 40 kHz have marked useful immuno-stimulatory activities.

Schematic Maps of Ocean Currents in the Yellow Sea and the East China Sea for Science Textbooks Based on Scientific Knowledge from Oceanic Measurements (관측 기반 과학적 지식에 근거한 과학교과서 황해 및 동중국해 해류모식도)

  • PARK, KYUNG-AE;PARK, JI-EUN;CHOI, BYOUNG-JU;LEE, SANG-HO;SHIN, HONG-RYEOL;LEE, SANG-RYONG;BYUN, DO-SEONG;KANG, BOONSOON;LEE, EUNIL
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.4
    • /
    • pp.151-171
    • /
    • 2017
  • Most of oceanic current maps in the secondary school science and earth science textbooks have been made on the base of extensive in-situ measurements conducted by Japanese oceanographers during 1930s. According to up-to-date scientific knowledge on the currents in the Yellow Sea and the East China Sea (YES), such maps have significant errors and are likely to cause misconceptions to students, thus new schematic map of ocean currents is needed. The currents in the YES change seasonally due to relatively shallow water depths, complex terrain, winds, and tides. These factors make it difficult to construct a unified ocean current map of the YES. Sixteen major items, such as the flow of the Kuroshio Current into the East China Sea and its northward path, the origin of the Tsushima Warm Current and its path into the Korea Strait, the path of Taiwan Warm Current, the Jeju Warm Current, the runoff pattern of the Yangtze River flow, the routes of the northward Yellow Sea Warm Current, the Chinese Coastal Current, and the West Korea Coastal Current off the west coast of the Korean Peninsula, were selected to produce the schematic current map. Review of previous scientific researches, in-depth discussions through academic conferences, expert discussions, and consultations for three years since 2014 enabled us to produce the final ocean current maps for the YES after many revisions. Considering the complexity of the ocean currents, we made seven ocean current maps: two representative current patterns in summer and winter, seasonal current maps for upper layer and lower layer in summer and winter, and one representative surface current map. It is expected that the representative maps of the YES, connected to the current maps of the East Sea and the Northwest Pacific Ocean, would be widely utilized for diverse purposes in the secondary-school textbooks as well as high-level educational purposes and even for scientific scholarly experts.

Comparison of shear, tensile and shear/tensile combined bonding strengths in bracket base configurations (브라켓 기저부 형태에 따른 전단, 인장, 전단/인장복합결합강도의 비교)

  • Lee, Choon-Bong;Lee, Seong-Ho;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.599-611
    • /
    • 1999
  • The purpose of this study was to evaluate shear, tensile and shear/tensile combined bond strengths(SBS, TBS, S/TBS) in various orthodontic brackets bonded to human teeth with chemically cured adhesive (Ortho-one, Bisco, USA). Five types of metal brackets with various bracket base configurations (Micro-Loc base(Tomy, Japan), Chessboard base(Daesung, Korea), Non-Etched Foil Mesh base(Dentarum, Germany), Micro-Etched Foil Mesh base(Ortho Organiners, USA), Integral base(Unitek, USA)) were used in this study. Shear, tensile and shear/tensile combined bond strengths according to the direction of force were measured by universal testing machine. The bracket base surface after bond strength test were examined by stereoscope and scanning electron microscope. The assessment of resin remnant on bracket base surface was carried out by ARI(adhesive remnant index). The results obtained were summarized as follows, 1. In all brackets, SBS was in the greatest value(p<0.05), TBS was in 50% level and S/TBS was in 30% level of SBS. 2. In bond strength, Micro-Loc base bracket showed the maximum bond strength($SBS:22.86{\pm}1.37kgf,\;TBS:11.37{\pm}0.42kgf,\;S/TBS:6.69{\pm}0.34kgf$) and Integral base bracket showed the minimum bond strength($SBS:10.52{\pm}1.27kgf,\;TBS:4.27{\pm}1.08kgf,\;S/TBS:2.94{\pm}0.58kgf) (p<0.05). 3. In bond strength per unit area, Integral base bracket showed the minimum value, Micro-Loc base and Chessboard base brackets were in similar value(p>0.05). Non-Etched Foil Mesh base and Micro-Etched Foil Mesh base bracket were similar in SBS and TBS(p>0.05), but Micro-Etched Foil Mesh base bracket was greater than Non-Etched Foil Mesh base bracket in S/TBS(p<0.05). 4. Bond failure sites were mainly between bracket base and adhesive, therefore ARI scores were low.

  • PDF

The Early Results of Endovenous Radiofrequency Ablation Using the 7 Fr. VNUS $ClosureFAST^{(R)}$ System in Varicose Veins (혈관 내 고주파열치료법인 7 Fr. VNUS $ClosureFAST^{(R)}$ System을 이용한 하지 정맥류 치료의 조기 결과)

  • Ryu, Sang-Woo;Oh, Hye-Ryung;Kim, Mi-Kyung;Moon, Seung-Ho;CheKar, Jay-Key;Yun, Ju-Sik;Hong, Seong-Beom
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.238-243
    • /
    • 2009
  • Background: Radiofrequency obliteration and endovenous laser therapy of the greater saphenous vein have recently been introduced as alternative, minimally invasive techniques for the treatment of saphenous vein incompetence. The 7 Fr. VNUS $ClosureFAST^{(R)}$ radiofrequency obliteration system was introduced in Gwang-Ju Veterans hospital. The purpose of this study is to evaluate the efficacy and complications of radiofrequency obliteration using the 7 Fr. VNUS $ClosureFAST^{(R)}$ system. Material and Method: Between May 2, 2007 and May 31, 2008, we performed radiofrequency obliteration on 90 patients. The number of males was 67 and their mean age was $57.9{\pm}11.0$ (range: $23{\sim}78$) years old. The patients underwent follow up exams at 3 weeks after the procedures and then every 3 months. The effects of treatment and the complications were reviewed. Result: The postoperative complications were ecchymosis (94.4%), pain (27.8%), paresthesia (25.6%), bullous formation (8.9%), edema (6.7%) and phlebitis (2.2%). One patient showed good blood flow after 3 weeks and one patient showed good blood flow after 3 months. The one-year success rate of radiofrequency obliteration in varicose veins was 97.6%. Conclusion: Our data showed acceptable operative results and short-term clinical results for treating varicose veins with radio frequency obliteration. Long-term follow-up and comparison of radio frequency obliteration with high ligation and stripping, previous radiofrequency ablation and endovenous laser therapy are needed in the future.

Proposal of New Criteria for Assessing Respiratory Impairment (새로운 호흡기 장애 판정 기준의 제안)

  • Park, Joo-Hun;Lee, Jae-Seung;Huh, Jin-Won;Oh, Yeon-Mok;Lee, Sang-Do;Lee, Sei-Won;Yoon, Ho-Il;Kim, Deog-Kyeom;Lee, Chang-Hoon;Park, Myung-Jae;Kim, Eun-Kyung;Park, Yong-Bum;Hwang, Yong-Il;Jung, Ki-Suck;Park, Hye-Yoon;Lim, Seong-Yong;Jung, Ji-Ye;Kim, Young-Sam;Kim, Hui-Jung;Rhee, Chin-Kook;Yoon, Hyoung-Kyu;Kim, Young-Kyoon;Kim, Jin-Woo;Yoo, Jee-Hong;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.3
    • /
    • pp.199-205
    • /
    • 2011
  • Social welfare services for respiratory-disabled persons in Korea are offered based on the respiratory impairment grade, which is determined by 3 clinical parameters; dyspnea, forced expiratory volume in 1 second ($FEV_1$), and arterial oxygen tension. This grading system has several limitations in the objective assessment of respiratory impairment. We reviewed several guidelines for the evaluation of respiratory impairment and relevant articles. Then, we discussed a new grading system with respiratory physicians. Both researchers and respiratory physicians agreed that pulmonary function tests are essential in assessing the severity of respiratory impairment, forced vital capacity (FVC), $FEV_1$ and single breath diffusing capacity ($DL_{co}$) are the primarily recommended tests. In addition, we agreed that arterial blood gas analysis should be reserved for selected patients. In conclusion, we propose a new respiratory impairment grading system utilizing a combination FVC, $FEV_1$ and $DL_{co}$ scores, with more social discussion included.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Clinical Features of Acute Pancreatitis in Children (소아 급성 췌장염의 임상적 고찰)

  • Seo, Jung-Ho;Kim, Seong-Heon;Jeong, Sang-Geon;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.13 no.1
    • /
    • pp.58-65
    • /
    • 2010
  • Purpose: Since there are few studies involving acute pancreatitis in children, we reviewed our experience with this medical condition to describe the clinical features. Methods: A retrospective analysis was conducted by reviewing the medical records of 41 patients with AP who were admitted to the Department of Pediatrics of Pusan National University Hospital between January 1996 and June 2007. Results: Twenty males and 21 females (mean age, 8.7${\pm}$4.5 years) were included. In 22 patients (53.7%), no definitive causes were found. The most common etiologies were choledochal cysts (22.0%). Necrotizing pancreatitis was diagnosed in 5 patients (12.2%), and recurrent acute pancreatitis in 4 patients (9.8%). CT findings included pancreatic swelling (43.9%), peripancreatic fluid collection (29.3%), ascites (24.4%), and peripancreatic fat necrosis (12.2%). Serum amylase and lipase levels at diagnosis were 535.3${\pm}$553.2 and 766.2${\pm}$723.6 U/L, respectively, and were normalized within 1 week in 22 and 14 patients, respectively. On the basis of the Balthazar scale, 2 patients were diagnosed with severe AP. In 4 patients (9.8%), a surgical procedure was indicated. Major complications included ascites (32.3%), sepsis (16.1%), and pseudocyst and renal impairments (12.9%). Two patients died from multi-organ failure. Conclusion: The etiologies of AP in children are varied. Most children have a single episode and a self-limited course. However, AP of childhood still carries significant morbidity and mortality. Early diagnosis, appropriate treatment according to disease severity, and management of complications are important.

Contributors of the Severity of Airflow Limitation in COPD Patients

  • Hong, Yoon-Ki;Chae, Eun-Jin;Seo, Joon-Beom;Lee, Ji-Hyun;Kim, Eun-Kyung;Lee, Young-Kyung;Kim, Tae-Hyung;Kim, Woo-Jin;Lee, Jin-Hwa;Lee, Sang-Min;Lee, Sang-Yeub;Lim, Seong-Yong;Shin, Tae-Rim;Yoon, Ho-Il;Sheen, Seung-Soo;Ra, Seung-Won;Lee, Jae-Seung;Huh, Jin-Won;Lee, Sang-Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Background: Although airway obstruction in chronic obstructive pulmonary disease (COPD) is due to pathologic processes in both the airways and the lung parenchyma, the contribution of these processes, as well as other factors, have not yet been evaluated quantitatively. We therefore quantitatively evaluated the factors contributing to airflow limitation in patients with COPD. Methods: The 213 COPD patients were aged >45 years, had smoked >10 pack-years of cigarettes, and had a post-bronchodilator forced expiratory volume in one second ($FEV_1$)/forced vital capacity (FVC) <0.7. All patients were evaluated by medical interviews, physical examination, spirometry, bronchodilator reversibility tests, lung volume, and 6-minute walk tests. In addition, volumetric computed tomography (CT) was performed to evaluate airway wall thickness, emphysema severity, and mean lung density ratio at full expiration and inspiration. Multiple linear regression analysis was performed to identify the variables independently associated with $FEV_1$ - the index of the severity of airflow limitation. Results: Multiple linear regression analysis showed that CT measurements of mean lung density ratio (standardized coefficient ${\beta}$=-0.46; p<0.001), emphysema severity (volume fraction of the lung less than -950 HU at full inspiration; ${\beta}$=-0.24; p<0.001), and airway wall thickness (mean wall area %; ${\beta}$=-0.19, p=0.001), as well as current smoking status (${\beta}$=-0.14; p=0.009) were independent contributors to $FEV_1$. Conclusion: Mean lung density ratio, emphysema severity, and airway wall thickness evaluated by volumetric CT and smoking status could independently contribute to the severity of airflow limitation in patients with COPD.