• Title/Summary/Keyword: SensorML

Search Result 105, Processing Time 0.025 seconds

A Consideration on ML Blind Signal Estimation based on Finite-Alphabet Characteristic in QPSK Modulation (QPSK 신호 입력시스템에서의 유한 알파벹 기반 ML 블라인드 신호 추정 비교)

  • Kwon, S.M.;Kim, S.J.;Lee, J.M.;Kim, C.K.;Cheon, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.685-688
    • /
    • 2003
  • In this paper, a performance comparison between two blind signal estimation algorithms in a LTI channel is considered. The two algorithms, Iterative Least-Squares with Projection (ILSP) and a modified ILSP, are based on the finite-alphabet property of input symbols. This case typically arises in a multiple access system with a sensor array antenna at the receiving end. We start with the formulation of a maximum-likelihood (ML) estimation problem under an additive white Gaussian noise assumption. A blind ML estimator is derived with its iterative algorithm for calculation. Then we narrow down the consideration of this problem to QPSK case so that a modified algorithm is proposed for $\pi$/4-QPSK case. The modified version is compared with the original ILSP algorithm in terms of the rate of the convergence to global minima. A computer simulation shows that the modified algorithm gives a better performance. This result implies that the performance of the blind separation algorithms may be greatly improved by adopting a smart coding scheme with rich structure.

  • PDF

Fabrication of a Micro Electromagnetic Flow Sensor for Micro Flow Rate Measurement (미소 유량 측정을 위한 마이크로 전자 유량 센서의 제작)

  • Yoon, Hyeun-Joong;Kim, Soon-Young;Yang, Sang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.334-340
    • /
    • 2000
  • This paper presents the fabrication of a micro electromagnetic flow sensor for the liquid flow rate measurement. The micro electromagnetic flow sensor has some advantages such as a simple structure, no heat generation, a rapid response and no pressure loss. The principle of the micro electromagnetic flow sensor is based on Faraday's law. If conductive fluid passes through a magnetic field, the electromotive force is generated and detected by two electrodes on the wall of the flow channel. The flow sensor consists of two permanent magnets and a silicon flow channel with two electrodes. The dimension of the flow sensor is $9\;mm\;{\times}\;9\;mm\;{\times}\;1\;mm$. The micro flow channel is mainly fabricated by anisotropic etching of two silicon wafers, and the detection electrodes are fabricated by metal evaporation process. The characteristic of the fabricated flow sensor is obtained experimentally. When the flow rates of water with the conductance of $100-200\;{\mu}S/cm$ are 9.1 ml/min and 62 ml/min, the generated electromotive forces are $261\;{\mu}V$ and 7.3 mV, respectively.

  • PDF

Development of an SH-SAW Sensor for Protein Measurement (단백질 측정용 SH-SAW 센서 개발)

  • 권용준;김재호;고광락;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • We developed SH-SAW sensors to detect protein molecules in liquid solutions applying a particular antibody thin film on the delay line of transverse SAW devices. The antibody investigated was human-immune-globulin G (HigG) to hold the antigens (anti-HigG) in the protein solution. We fabricated the sensor generating 100 MHz with the piezoelectric single crystal LiTaO₃. We measured the frequency change of the sensor by adding the anti-body concentration on SAM (self assembled monolayer) deposited on the Au layer. The sensor showed stable response to the mass loading effects of the anti-HigG molecules with the sensitivity up to 10.8 ng/ml/Hz at noise level 400 Hz below.

FET type Urea Sensor (FET형 요소 감지 소자)

  • Moon, Byung-Joon;Lee, Jong-Hyun;Sohn, Byung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.490-492
    • /
    • 1987
  • Urea-Sensor was fabricated by immobilizing urease on ISFET's gate using BSA(bovine serum albumin) and glutaraldehyde, and its characteristics were examined. This sensor showed approximately linear characteristic in the urea concentration range of $3{\times}10^{-5}-10^{-9}$ (g/ml). Fast response time was obtained and minute amounts of expensive enzyme were used in comparison to general electrode type biosensors.

  • PDF

Spatio-Temporal Semantic Sensor Web based on SSNO (SSNO 기반 시공간 시맨틱 센서 웹)

  • Shin, In-Su;Kim, Su-Jeong;Kim, Jeong-Joon;Han, Ki-Joon
    • Spatial Information Research
    • /
    • v.22 no.5
    • /
    • pp.9-18
    • /
    • 2014
  • According to the recent development of the ubiquitous computing environment, the use of spatio-temporal data from sensors with GPS is increasing, and studies on the Semantic Sensor Web using spatio-temporal data for providing different kinds of services are being actively conducted. Especially, the W3C developed the SSNO(Semantic Sensor Network Ontology) which uses sensor-related standards such as the SWE(Sensor Web Enablement) of OGC and defines classes and properties for expressing sensor data. Since these studies are available for the query processing about non-spatio-temporal sensor data, it is hard to apply them to spatio-temporal sensor data processing which uses spatio-temporal data types and operators. Therefore, in this paper, we developed the SWE based on SSNO which supports the spatio-temporal sensor data types and operators expanding spatial data types and operators in "OpenGIS Simple Feature Specification for SQL" by OGC. The system receives SensorML(Sensor Model Language) and O&M (Observations and Measurements) Schema and converts the data into SSNO. It also performs the efficient query processing which supports spatio-temporal operators and reasoning rules. In addition, we have proved that this system can be utilized for the web service by applying it to a virtual scenario.

Measurement of Glucose Concentration Using a μFIA Biosensor (μFIA 바이오 센서를 이용한 포도당 농도 측정)

  • ;Joseph Irudayaraj
    • Journal of Biosystems Engineering
    • /
    • v.28 no.5
    • /
    • pp.465-468
    • /
    • 2003
  • A microdialysis coupled flow injection amperometric biosensor was calibrated to measure the concentration of glucose using 7 standard samples from 10ml to 70ml of glucose solution. The output of the sensor increased linearly with an increase in the glucose concentration with an $R^2$ correlation of 0.99. The amperometric biosensor was then applied to measure the. glucose concentration of 2 commercial samples(Orange and Pineapple juice) and the results compared with HPLC. Around 12% error was observed in glucose concentration measurements of the samples analyzed. The sensor has potential in rapid measurement once the calibration is done. Potential for on-line sensing is also discussed.

Measurement of Sucrose Concentration Using a μFIA Biosensor (μFIA 바이오센서를 이용한 자당 농도 측정)

  • Song D. B.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.553-557
    • /
    • 2004
  • A microdialysis coupled flow injection amperometric $({\mu}FIA)$ biosensor was calibrated to measure the concentration of sucrose using 11 standard samples from 2 ml to 70 ml of sucrose solution. The output of the sensor increased linearly with an increase in the sucrose concentration with an $r^2$ correlation of 0.99. The amperometric biosensor was then applied to measure the sucrose concentration of 4 commercial samples (Orange and Pineapple juices, Pepsi, Sprite) and the results compared with those by HPLC. Around $20\~30\%$ error was observed in sucrose concentration measurements of the samples analyzed. The sensor has potential in rapid measurement once the calibration is done. Potential for on-line sensing is also discussed.

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • v.31 no.1
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

Fiber-optic fluoroimmunosensor for foodborn pathogens using an optical evanescent field (광섬유 소산장을 이용한 식중독균 신속검출용 형광면역센서)

  • Yeom, Se-Hyuk;Park, Chang-Sub;Kim, Do-Eok;Kim, Kyu-Jin;Kang, Byoung-Ho;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.441-448
    • /
    • 2007
  • In this study, the fiber-optic fluoro-immunosensor was designed to detect foodborne pathogens. The fabricated system is composed of the multimode optical fiber on which antibodies are immobilized. Then, a sandwich immunoassay is applied to the fabricated the fiber-optic fluoro-immunosensor. In the "sandwich" binding format, a primary or "capture" antibody is immobilized on the core surface of the multimode optical fiber and a secondary or named as "tracer" antibody is added to the bulk solution. A tracer is labeled FITC (fluorescein isothiocyanate; ${\lambda}ex$=492 nm, ${\lambda}em$= 520 nm). Different concentrations of antigens are tested in different fibers. The detection limit of the fabricated system is 5.08×103 cfu/ml for Vibrio antigen and $0.1{\mu}g/ml$, $0.05{\mu}g/ml$ in non-labeled monolayer phosphate buffered saline (NMP), non-labeled monolayer carbonate bicarbonate buffer (NMC), respectively.

Development of Assembly for Fast BOD Estimation and Its Applications (신속한 BOD 측정장치의 개발과 응용)

  • Soon, Moo-Jeong;Kim, Eun-Jeong;Jang, Seh-Yong;Hong, Daeil
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.285-291
    • /
    • 1994
  • A microbial BOD sensor for the continuous estimation of BOD was been developed by immobilizing Trichosporon cutaneum, which was immobilized between a dialysis and a gas-permeable membrane, on an oxygen electrode. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $32{\sim}33^{\circ}C$, respectively. The best result was obtained at 2~3ml/min flow rate in 0.1M phosphate buffer solution. A linear relationship was observed between ${\Delta}DO$ and the concentration of standard GGA solution below 60mg/l(90ppm $BOD_5$). The reproducibility was found to be within 3% for the standard solution containing glucose 30mg/l and glutamic acid 30mg/l. The output DO value of this sensor was almost constant for 30 dalys. The response time and the recovery time were about 5 and 10 min, respectively. This sensor was employed for the BOD measurement of waste pollutants and was compared with $BOD_5$ method.

  • PDF