• Title/Summary/Keyword: Sensor-based

Search Result 10,185, Processing Time 0.037 seconds

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

Determination of Total CO2 and Total Alkalinity of Seawater Based on Thermodynamic Carbonate Chemistry (해수중의 총이산화탄소와 총알칼리도 분석을 위한 탄산염 화학 이론 및 측정방법)

  • Mo, Ahra;Son, Juwon;Park, Yongchul
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • To evaluate accuracy and precision of determination of total alkalinity ($Alk_T$) and carbon dioxide ($TCO_2$) derived from present study, experiment was applied with $CO_2$ CRM (Batch 132, Scripps Institution of Oceanography; $Alk_T=2229.24{\pm}0.39{\mu}mol/kg$, $TCO_2=2032.65{\pm}0.45{\mu}mol/kg$). As the result, average concentration of $Alk_T$ and $TCO_2$ was $2354.09{\mu}mol/kg$ (~5.6% difference with $CO_2$ CRM) and $2089.60{\mu}mol/kg$ (~2.3% difference with $CO_2$ CRM), respectively. For previous method (Gran Titration) by addition $NaHCO_3$ to deionized water($Alk_T$ $2023.33{\mu}mol/kg$), average concentration was $2193.39{\mu}mol/kg$ (sd=57.15, n=7). Whereas, average concentration was $2017.02{\mu}mol/kg$ (sd=10.98, n=7) for the present study. Recovery yield experiments of total alkalinity in deionized water and seawater were implemented by addition of $NaHCO_3$. The recovery yield of deionized water in the range 0 to $4952.39{\mu}mol/kg$ was 100.8% ($R^2$=0.999), and seawater in the range 0 to $2041.32{\mu}mol/kg$ was 102.3% ($R^2$=0.999). Comparison of $pCO_2$ sensor (PSI $CO_2-Pro^{TM}$) with present method showed very meaningful correlation coefficient ($R^2$=0.977) in the range of 427 to $705{\mu}atm$ and 9.16 to $15.24{\mu}mol/kg$ throught elapsed time for two weeks. Field experiment of diurnal variation of total carbon dioxide was accomplished at Sachon harbor in the coastal waters of East Sea of Korea. Concentration of $Alk_T$ and $TCO_2$ was increased during night, and decreased during daylight hours. The results showed mirror type between $TCO_2$ and dissolved oxygen, which was attributable to photosynthesis and respiration of phytoplankton. Also, open ocean field study was performed to obtain vertical profile of $Alk_T$ and $TCO_2$ in C-C zone (Clarion-Clipperton Fracture Zone), Northeastern Pacific. Average concentrations of $Alk_T$ in the surface mixed layer (0~60 m) and deeper layer below 200 m were $2422.38{\mu}mol/kg$ (sd=78.73, n=20) and $2465.87{\mu}mol/kg$ (sd=57.68, n=103), respectively. And average concentrations of $TCO_2$ were $2134.47{\mu}mol/kg$ (sd=65.4, n=20) and $2431.87{\mu}mol/kg$ (sd=65.02, n=103) in the same depth ranges such as $Alk_T$. Vertical distributions of $Alk_T$ and $TCO_2$ concentrations tended to increase with depth, and analyzed concentrations showed slightly higher than those of previous studies in this area.

Development of New Device for the Rapid Measurement of the freshness of Wet Fish by Using Micro Computer (마이크로 컴퓨터를 이용한 어육의 신선도 측정장치의 개발)

  • CHO Young-Je;LEE Nam-Geoul;KIM Sang-Bong;CHOI Young-Joon;LEE Keun-Woo;KIM Geon-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.253-262
    • /
    • 1995
  • To develop a device for measuring fish freshness which could be move accurate and reliable than used freshness measuring systems. A new device based on digital circuit was designed using a microcomputer. The device was composed of a sensor part, 8096 microprocessor and a segment display. The effectiveness of device has been evaluated by the coefficient of correlation among the measured freshness stores such as electrical Q-value, K-value and amount of volatile basic nitrogen (VBN) of plaice, Paralichthys Olivaceus, during storage at $-3^{\circ}C,\;0^{\circ}C,\;5^{\circ}C,\;10^{\circ}C,\;and\;25^{\circ}C$. Q-values measured by a new device were more closely correlated with K-value (r=-0.978-\;-0.962,\;p<0.05) and VBN (r=-0.888-\;-0.988,\;p<0.05) in case of plaice meat. If more data would achieve using various fishes, this new designed device could be a valuable kit in fish market by its compact portability.

  • PDF

System Development for Measuring Group Engagement in the Art Center (공연장에서 다중 몰입도 측정을 위한 시스템 개발)

  • Ryu, Joon Mo;Choi, Il Young;Choi, Lee Kwon;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.45-58
    • /
    • 2014
  • The Korean Culture Contents spread out to Worldwide, because the Korean wave is sweeping in the world. The contents stand in the middle of the Korean wave that we are used it. Each country is ongoing to keep their Culture industry improve the national brand and High added value. Performing contents is important factor of arousal in the enterprise industry. To improve high arousal confidence of product and positive attitude by populace is one of important factor by advertiser. Culture contents is the same situation. If culture contents have trusted by everyone, they will give information their around to spread word-of-mouth. So, many researcher study to measure for person's arousal analysis by statistical survey, physiological response, body movement and facial expression. First, Statistical survey has a problem that it is not possible to measure each person's arousal real time and we cannot get good survey result after they watched contents. Second, physiological response should be checked with surround because experimenter sets sensors up their chair or space by each of them. Additionally it is difficult to handle provided amount of information with real time from their sensor. Third, body movement is easy to get their movement from camera but it difficult to set up experimental condition, to measure their body language and to get the meaning. Lastly, many researcher study facial expression. They measures facial expression, eye tracking and face posed. Most of previous studies about arousal and interest are mostly limited to reaction of just one person and they have problems with application multi audiences. They have a particular method, for example they need room light surround, but set limits only one person and special environment condition in the laboratory. Also, we need to measure arousal in the contents, but is difficult to define also it is not easy to collect reaction by audiences immediately. Many audience in the theater watch performance. We suggest the system to measure multi-audience's reaction with real-time during performance. We use difference image analysis method for multi-audience but it weaks a dark field. To overcome dark environment during recoding IR camera can get the photo from dark area. In addition we present Multi-Audience Engagement Index (MAEI) to calculate algorithm which sources from sound, audience' movement and eye tracking value. Algorithm calculates audience arousal from the mobile survey, sound value, audience' reaction and audience eye's tracking. It improves accuracy of Multi-Audience Engagement Index, we compare Multi-Audience Engagement Index with mobile survey. And then it send the result to reporting system and proposal an interested persons. Mobile surveys are easy, fast, and visitors' discomfort can be minimized. Also additional information can be provided mobile advantage. Mobile application to communicate with the database, real-time information on visitors' attitudes focused on the content stored. Database can provide different survey every time based on provided information. The example shown in the survey are as follows: Impressive scene, Satisfied, Touched, Interested, Didn't pay attention and so on. The suggested system is combine as 3 parts. The system consist of three parts, External Device, Server and Internal Device. External Device can record multi-Audience in the dark field with IR camera and sound signal. Also we use survey with mobile application and send the data to ERD Server DB. The Server part's contain contents' data, such as each scene's weights value, group audience weights index, camera control program, algorithm and calculate Multi-Audience Engagement Index. Internal Device presents Multi-Audience Engagement Index with Web UI, print and display field monitor. Our system is test-operated by the Mogencelab in the DMC display exhibition hall which is located in the Sangam Dong, Mapo Gu, Seoul. We have still gotten from visitor daily. If we find this system audience arousal factor with this will be very useful to create contents.