• Title/Summary/Keyword: Sensor technology

Search Result 8,666, Processing Time 0.044 seconds

The characteristics of electrochemical etch-stop in THAH/IPA/pyrazine solution (TMAH/IPA/pyrazine 용액에서의 전기화학적 식각정지특성)

  • Chung, G.S.;Park, C.S.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.426-431
    • /
    • 1998
  • This paper describes electrochemical etch-stop characteristics in THAH/IPA/pyrazine solution. I-V curves of n- and p-type Si in THAH/IPA/pyrazine solution were obtained. OCP(Open Circuit Potential) and PP (Passivation Potential) of p-type Si were -1.2 V and 0.1 V, and of n-type Si were -1.3 V and -0.2 V, respectively. Both n- and p-type Si, etching rates were abruptly decreased at potentials anodic to the PP. The etch-stop characteristics in THAH/IPA/pyrazine solution were observed. Since accurate etching stop occurs at pn junction, Si diaphragms having thickness of epi-layer were fabricated. Etching rate is highest at optimum etching condition, TMAH 25wt.%/IPA 17vol.%/pyrazine 0.1g/100ml. thus the elapsed time of etch-stop was reduced.

  • PDF

An Electrical Properties of Antifuses based on $BaTiO_3/SiO_2$ films ($BaTiO_3/SiO_2$로 구성된 안티퓨즈의 전기적 특성)

  • Lee, Young-Min;Lee, Jae-Sung;Lee, Yong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.364-371
    • /
    • 1998
  • A novel antifuse has been developed for field programmable gate arrays (FPGA's) as a voltage programmable link with Al/$BaTiO_3/SiO_2$/TiW-silicide. The proper program voltage can be obtained by adjusting the deposition thickness of $BaTiO_3$ film. When a negative voltage was applied at bottom TiW-silicide electrode of the antifuse, based on $BaTiO_3(120{\AA})$/$SiO_2(120{\AA})$, the program voltage was about l4.4V and on-resistances were ranged between 40 and $50{\Omega}$. The current-voltage characteristics of antifuses are consistent with a Frenkel-Poole conduction model. However, there are some deviations depending on bias polarity that are probably due to the difference in the interface properties between Al/$BaTiO_3$ and TiW-silicide/$SiO_2$.

  • PDF

Preparation of $NbS_2$ thin film using PLD method (PLD 장치를 이용한 $NbS_2$ 박막의 제작)

  • Park, Jong-Man;Lee, Hea-Yeon;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.372-376
    • /
    • 1998
  • We developed a pulsed laser deposition(PLD) apparatus for depositing various thin films. In this study, the formation of $NbS_2$ thin film was performed in the vacuum chamber by PLD method. $Al_2O_3$(012) and Si(111) were used as the substrates. In order to investigate the growth conditions of a high crystalline $NbS_2$ thin film, the S/Nb composition ratio was varied from 2.0 to 5.25 and the substrate temperature was varied from the room temperature to $600^{\circ}C$. From the result of X-ray diffraction studies of the prepared $NbS_2$ thin films, it was reported that the $NbS_2$, thin film showed a good crystallinity at substrate temperature $600^{\circ}C$ and with S/Nb composition ratio 4.0 on $Al_2O_3$(012) but did not on Si(111). The films exhibited c-axis orientation.

  • PDF

Phase Transition and Relaxation Properties of Nonlinear-Optical KTP Single Crystal (비선형광학 단결정 KTP의 상전이 및 완화특성에 관한 연구)

  • Choi, Byung-Chun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.386-393
    • /
    • 1998
  • We have carried out the measurements of complex dielectric constants with impedance/gain-phase analyzer using capacitor method and the experiments of high temperature X-ray powder diffraction with X-ray diffractometer using ${\theta}-2{\theta}$ scan method for the KTP single crystal which has the premium nonlinear optical properties. From the results of high temperature X-ray powder diffraction experiments, we have found that KTP does not undergo structural phase transition below $900^{\circ}C$. It is clear that KTP undergoes structural phase transition around $900^{\circ}C$ and belongs to orthorhombic above $900^{\circ}C$ still. However, we have applied phenomenological relation of dielectric relaxation to the results of complex dielectric measurement and have found that relaxation mechanism of KTP well satisfies the Cole-Cole relation over the temperature range from $-78^{\circ}C$ to $200^{\circ}C$. And also the relaxation time well satisfies the Vogel-Fulcher relation. It is regarded that the hopping and thermally activated diffusion mechanism may control the conduction behavior of KTP above $200^{\circ}C$.

  • PDF

Individual Pig Detection Using Kinect Depth Information and Convolutional Neural Network (키넥트 깊이 정보와 컨볼루션 신경망을 이용한 개별 돼지의 탐지)

  • Lee, Junhee;Lee, Jonguk;Park, Daihee;Chung, Yongwha
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.1-10
    • /
    • 2018
  • Aggression among pigs adversely affects economic returns and animal welfare in intensive pigsties. Recently, some studies have applied information technology to a livestock management system to minimize the damage resulting from such anomalies. Nonetheless, detecting each pig in a crowed pigsty is still challenging problem. In this paper, we propose a new Kinect camera and deep learning-based monitoring system for the detection of the individual pigs. The proposed system is characterized as follows. 1) The background subtraction method and depth-threshold are used to detect only standing-pigs in the Kinect-depth image. 2) The standing-pigs are detected by using YOLO (You Only Look Once) which is the fastest and most accurate model in deep learning algorithms. Our experimental results show that this method is effective for detecting individual pigs in real time in terms of both cost-effectiveness (using a low-cost Kinect depth sensor) and accuracy (average 99.40% detection accuracies).

Performance Improvement of Isolated High Voltage Full Bridge Converter Using Voltage Doubler

  • Lee, Hee-Jun;Shin, Soo-Cheol;Hong, Seok-Jin;Hyun, Seung-Wook;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2224-2236
    • /
    • 2014
  • The performance of an isolated high voltage full bridge converter is improved using a voltage doubler. In a conventional high voltage full bridge converter, the diode of the transformer secondary voltage undergoes a voltage spike due to the leakage inductance of the transformer and the resonance occurring with the parasitic capacitance of the diode. In addition, in the phase shift control, conduction loss largely increases from the freewheeling mode because of the circulating current. The efficiency of the converter is thus reduced. However, in the proposed converter, the high voltage dual converter consists of a voltage doubler because the circulating current of the converter is reduced to increase efficiency. On the other hand, in the proposed converter, an input current is distributed when using parallel input / serial output and the output voltage can be doubled. However, the voltages in the 2 serial DC links might be unbalanced due to line impedance, passive and active components impedance, and sensor error. Considering these problems, DC injection is performed due to the complementary operations of half bridge inverters as well as the disadvantage of the unbalance in the DC link. Therefore, the serial output of the converter needs to control the balance of the algorithm. In this paper, the performance of the conventional converter is improved and a balance control algorithm is proposed for the proposed converter. Also, the system of the 1.5[kW] PCS is verified through an experiment examining the operation and stability.

Construction of Multi-agent-based Distributed Framework for Application Services of u-Hospital Information Systems (u-병원 정보 시스템의 응용 서비스를 위한 멀티에이전트 기반 분산 프레임워크 구축)

  • Jeong, Chang-Won;Shin, Chang-Sun;Joo, Su-Chong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.11
    • /
    • pp.861-865
    • /
    • 2009
  • As the hospital environment has been increasingly changed into a ubiquitous environment, the application services for the hospital environment are also faced with new requirements. In particular, the emergence of various mobile devices and the introduction of a wireless sensor network technology have accelerated the realization of the u-healthcare. The multi-agent paradigm has been introduced for satisfying both the integration of information and the various application scenarios established from various environments. This paper describes the software structure and u-applications for u-hospital information system based on ubiquitous environments. And it suggested the construction of a multi agent based distributed framework for supporting u-hospital information system. The suggested framework includes the JADE and distributed object group framework. And it implemented u-application services for supporting doctors and nurses, which provides the patient's health information and ward environment information. Especially, it is using a dynamic security mechanism on the security situation, which has not been emphasized in existing researches, and this paper shows the results for each user through the GUI.

Monitoring of Environmental Arsenic by Cultures of the Photosynthetic Bacterial Sensor Illuminated with a Near-Infrared Light Emitting Diode Array

  • Maeda, Isamu;Sakurai, Hirokazu;Yoshida, Kazuyuki;Siddiki, Mohammad Shohel Rana;Shimizu, Tokuo;Fukami, Motohiro;Ueda, Shunsaku
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.12
    • /
    • pp.1306-1311
    • /
    • 2011
  • Recombinant Rhodopseudomonas palustris, harboring the carotenoid-metabolizing gene crtI (CrtIBS), and whose color changes from greenish yellow to red in response to inorganic As(III), was cultured in transparent microplate wells illuminated with a light emitting diode (LED) array. The cells were seen to grow better under near-infrared light, when compared with cells illuminated with blue or green LEDs. The absorbance ratio of 525 to 425 nm after cultivation for 24 h, which reflects red carotenoid accumulation, increased with an increase in As(III) concentrations. The detection limit of cultures illuminated with near-infrared LED was 5 ${\mu}g$/l, which was equivalent to that of cultures in test tubes illuminated with an incandescent lamp. A near-infrared LED array, in combination with a microplate, enabled the simultaneous handling of multiple cultures, including CrtIBS and a control strain, for normalization by the illumination of those with equal photon flux densities. Thus, the introduction of a near-infrared LED array to the assay is advantageous for the monitoring of arsenic in natural water samples that may contain a number of unknown factors and, therefore, need normalization of the reporter event.

Sensing Technology for Rapid Detection of Phosphorus in Water: A Review

  • Islam, Sumaiya;Reza, Md Nasim;Jeong, Jin-Tae;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.138-144
    • /
    • 2016
  • Purpose: Phosphorus is an essential element for water quality control. Excessive amounts of phosphorus causes algal bloom in water, which leads to eutrophication and a decline in water quality. It is necessary to maintain the optimum amount of phosphorus present. During the last decades, various studies have been conducted to determine phosphorus content in water. In this study, we present a comprehensive overview of colorimetric, electrochemical, fluorescence, microfluidic, and remote sensing technologies for the measurement of phosphorus in water, along with their working principles and limitations. Results: The colorimetric techniques determine the concentration of phosphorus through the use of color-generating reagents. This is specific to a single chemical species and inexpensive to use. The electrochemical techniques operate by using a reaction of the analyte of interest to generate an electrical signal that is proportional to the sample analyte concentration. They show a good linear output, good repeatability, and a high detection capacity. The fluorescence technique is a kind of spectroscopic analysis method. The particles in the sample are excited by irradiation at a specific wavelength, emitting radiation of a different wavelength. It is possible to use this for quantitative and qualitative analysis of the target analyte. The microfluidic techniques incorporate several features to control chemical reactions in a micro device of low sample volume and reagent consumption. They are cheap and rapid methods for the detection of phosphorus in water. The remote sensing technique analyzes the sample for the target analyte using an optical technique, but without direct contact. It can cover a wider area than the other techniques mentioned in this review. Conclusion: It is concluded that the sensing technologies reviewed in this study are promising for rapid detection of phosphorus in water. The measurement range and sensitivity of the sensors have been greatly improved recently.

Design and Implementation of Time Synchronizer for Advanced ZigBee Systems (개선된 지그비 시스템을 위한 시간 동기부 설계 및 구현)

  • Hwang, Hyunsu;Jung, Yongcheol;Jung, Yunho
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.5
    • /
    • pp.453-461
    • /
    • 2016
  • Recently, with the growth of various sensor applications, the need of wireless communication systems which can support variable data rate is increasing. Therefore, advanced ZigBee (AZB) systems that support the various data rate under 250 kbps are proposed. However, the preamble structure for AZB systems causes the complexity increase of time synchronization circuits. In this paper, we propose preamble structure and time synchronization algorithm which can solve the problem of the complexity increase of time synchronization circuits. Implementation results show that the proposed time synchronizer for AZB systems include the logic slices of 6.92 k and, which are reduced at the rate of 62.3% compared with existing architecture.