• Title/Summary/Keyword: Sensor extension

Search Result 193, Processing Time 0.019 seconds

Extension of Measurement Range of Gyro Sensor Data (누적형 자이로 센서 데이터의 최대측정영역 확장 방법)

  • Oh, Shi-Hwan;Kim, Jin-Hee
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.39-48
    • /
    • 2012
  • In case a measurement output of gyro sensor is an accumulated angle counts, it is usually provided as a binary bit counter which is allowed to roll-over at its maximum or minimum value. And it is a well known fact that the roll-over behavior restricts the measurement range of the processed sensor output below the actual measurable range of sensor hardware itself. In this study, a conventional sensor data processing method for a gyro with an accumulated angle output is introduced. And also, an improved method which can extend the processed output range over the conventional one is proposed. It is also derived that the increased range depends on the variation speed of a input signal. Finally, the derived equations and the performance of the proposed algorithm are verified using a computer simulation.

The Algorithm for an Energy-efficient Particle Sensor Applied LEACH Routing Protocol in Wireless Sensor Networks (무선센서네트워크에서 LEACH 라우팅 프로토콜을 적용한 파티클 센서의 에너지 효율적인 알고리즘)

  • Hong, Sung-Hwa;Kim, Hoon-Ki
    • Journal of the Korea Society for Simulation
    • /
    • v.18 no.3
    • /
    • pp.13-21
    • /
    • 2009
  • The sensor nodes that form a wireless sensor network must perform both routing and sensing roles, since each sensor node always has a regular energy drain. The majority of sensors being used in wireless sensor networks are either unmanned or operated in environments that make them difficult for humans to approach. Furthermore, since many wireless sensor networks contain large numbers of sensors, thus requiring the sensor nodes to be small in size and cheap in price, the amount of power that can be supplied to the nodes and their data processing capacity are both limited. In this paper, we proposes the WSN(Wireless Sensor Network) algorithm which is applied sensor node that has low power consumption and efficiency measurement. Moreover, the efficiency routing protocol is proposed in this paper. The proposed algorithm reduces power consumption of sensor node data communication. It has not researched in LEACH(Low-Energy Adaptive Clustering Hierarchy) routing protocol. As controlling the active/sleep mode based on the measured data by sensor node, the energy consumption is able to be managed. In the event, the data is transferred to the local cluster head already set. The other side, this algorithm send the data as dependent on the information such as initial and present energy, and the number of rounds that are transformed into cluster header and then transferred. In this situation, the assignment of each node to cluster head evenly is very important. We selected cluster head efficiently and uniformly distributed the energy to each cluster node through the proposed algorithm. Consequently, this caused the extension of the WSN life time.

Fabrication of Microcantilever Ultrasound Sensor and Its Application to the Scanning Laser Source Technique

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.6
    • /
    • pp.459-466
    • /
    • 2005
  • The scanning laser source (SLS) technique has been proposed recently as an effective way to investigate small surface-breaking defects, By monitoring the amplitude and frequency changes of the ultrasound generated as the SLS scans over a defect, the SLS technique has provided enhanced signal-to-noise performance compared to the traditional pitch-catch or pulse-echo ultrasonic methods, An extension of the SLS approach to map defects in microdevices is proposed by bringing both the generator and the receiver to the near-field scattering region of the defects, To facilitate near-field ultrasound measurement, silicon microcantilever probes are fabricated using microfabrication technique and their acoustical characteristics are investigated, Then, both the laser-generated ultrasonic source and the microcantilever probe are used to monitor near-field scattering by a surface-breaking defect.

Evaluation of Solution Mediator in Irrigation System Controlled by Drainage Level Sensor (배액전극제어법 적용시 배액 이동매개체 선발)

  • Kim, Sung-Eun;Sim, Sang-Youn;Lee, Sang-Don;Kim, Young-Shik
    • Journal of agriculture & life science
    • /
    • v.44 no.6
    • /
    • pp.23-26
    • /
    • 2010
  • Commercial fibers such as two kinds of micro-fiber, flannel, and cotton were analyzed for their nutrient solution absorption capacity to select hydrophilic mat used for the irrigation management by drainage level sensor in perlite bag culture. The selected mat was evaluated in terms of absorption capacity. Cotton had the highest absorption capacity and was revealed to be the most appropriate for the control system.

Fault Diagnosis of Linear Discrete-Time Systems Based on an Unknown Input Observer (미지입력 관측기를 이용한 신형 이산 시스템의 고장 진단)

  • ;Zeung Nam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.2
    • /
    • pp.35-44
    • /
    • 1994
  • In this paper, an observer for linear discrete systems with unknown inputs is presented. The suggested observer can estimate the system state vector and the unknown inputs simultaneously. As an extension of the observer, a new fault diagnosis observer for linear discrete systems with structured uncertainty is presented. The fault diagnosis observer can detect and identify the actuator and the sensor faults as well. The stability conditionsand the design methods of the each observers are presented and the usability of the observers is shown via numerical examples.

  • PDF

Congestion Control based on Genetic Algorithm in Wireless Sensor Network (무선 센서 네트워크에서 유전자 알고리즘 기반의 혼잡 제어)

  • Park, Chong-Myung;Lee, Joa-Hyoung;Jung, In-Bum
    • Journal of KIISE:Information Networking
    • /
    • v.36 no.5
    • /
    • pp.413-424
    • /
    • 2009
  • Wireless sensor network is based on an event driven system. Sensor nodes collect the events in surrounding environment and the sensing data are relayed into a sink node. In particular, when events are detected, the data sensing periods are likely to be shorter to get the more correct information. However, this operation causes the traffic congestion on the sensor nodes located in a routing path. Since the traffic congestion generates the data queue overflows in sensor nodes, the important information about events could be missed. In addition, since the battery energy of sensor nodes exhausts quickly for treating the traffic congestion, the entire lifetime of wireless sensor networks would be abbreviated. In this paper, a new congestion control method is proposed on the basis of genetic algorithm. To apply genetic algorithm, the data traffic rate of each sensor node is utilized as a chromosome structure. The fitness function of genetic algorithm is designed from both the average and the standard deviation of the traffic rates of sensor nodes. Based on dominant gene sets, the proposed method selects the optimal data forwarding sensor nodes for relieving the traffic congestion. In experiments, when compared with other methods to handle the traffic congestion, the proposed method shows the efficient data transmissions due to much less queue overflows and supports the fair data transmission between all sensor nodes as possible. This result not only enhances the reliability of data transmission but also distributes the energy consumptions across the network. It contributes directly to the extension of total lifetime of wireless sensor networks.

Integrated System for Autonomous Proximity Operations and Docking

  • Lee, Dae-Ro;Pernicka, Henry
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.43-56
    • /
    • 2011
  • An integrated system composed of guidance, navigation and control (GNC) system for autonomous proximity operations and the docking of two spacecraft was developed. The position maneuvers were determined through the integration of the state-dependent Riccati equation formulated from nonlinear relative motion dynamics and relative navigation using rendezvous laser vision (Lidar) and a vision sensor system. In the vision sensor system, a switch between sensors was made along the approach phase in order to provide continuously effective navigation. As an extension of the rendezvous laser vision system, an automated terminal guidance scheme based on the Clohessy-Wiltshire state transition matrix was used to formulate a "V-bar hopping approach" reference trajectory. A proximity operations strategy was then adapted from the approach strategy used with the automated transfer vehicle. The attitude maneuvers, determined from a linear quadratic Gaussian-type control including quaternion based attitude estimation using star trackers or a vision sensor system, provided precise attitude control and robustness under uncertainties in the moments of inertia and external disturbances. These functions were then integrated into an autonomous GNC system that can perform proximity operations and meet all conditions for successful docking. A six-degree of freedom simulation was used to demonstrate the effectiveness of the integrated system.

Wrist Rehabilitation Training Device Using Pneumatic Inflation and Deflation of Air Cells (에어셀을 이용한 손목 재활훈련 장치)

  • Lee, Youngjin;Jeong, Yujin;Koo, Kyo-In;Chee, Youngjoon
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.2
    • /
    • pp.37-42
    • /
    • 2015
  • In this paper, we propose a wrist rehabilitation training device using pneumatic inflation and deflation of air cells. By alternating inflation and deflation of upper and lower air cells, the device makes the flexional and extensional movement for wrist rehabilitation. With the angular displacement sensor, it measures the flexion-extension angle of the wrist during the training and the bending angle is used for the automatic control of the device. Using the sensor output, the regression equation was obtained to measure the bending angle of the wrist from a wrist rehabilitation training device. The measurement error of the device was evaluated by comparing the measurement output with the angle from the photograph. The measurement error of wrist bending angle between the sensor and photo was $3.2^{\circ}$ in average. With additional test and improvement, the pneumatic wrist rehabilitation training device might be used for rehabilitation training.

Extension of ReInForM Protocol for (m,k)-firm Real-time Streams in Wireless Sensor Networks

  • Li, Bijun;Kim, Ki-Il
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.3
    • /
    • pp.231-236
    • /
    • 2012
  • For real-time wireless sensor network applications, it is essential to provide different levels of quality of service (QoS) such as reliability, low latency, and fault-tolerant traffic control. To meet these requirements, an (m,k)-firm based real-time routing protocol has been proposed in our prior work, including a novel local transmission status indicator called local DBP (L_DBP). In this paper, a fault recovery scheme for (m,k)-firm real-time streams is proposed to improve the performance of our prior work, by contributing a delay-aware forwarding candidates selection algorithm for providing restricted redundancy of packets on multipath with bounded delay in case of transmission failure. Each node can utilize the evaluated stream DBP (G_DBP) and L_DBP values as well as the deadline information of packets to dynamically define the forwarding candidate set. Simulation results show that for real-time service, it is possible to achieve both reliability and timeliness in the fault recovery process, which consequently avoids dynamic failure and guarantees meeting the end-to-end QoS requirement.

Appropriate Sensor Height in an Irrigation Management System by Drainage Level Sensor for Perlite Bag Culture of Cucumber and Paprika (오이와 착색단고추의 펄라이트자루재배시 배액전극제어법에서의 적정 배액전극높이 구명)

  • Kim, Sung-Eun;Sim, Sang-Youn;Lee, Sang-Don;Kim, Young-Shik
    • Journal of agriculture & life science
    • /
    • v.45 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • An experiment was conducted to test different heights of drainage level sensors in an irrigation management system for perlite bag culture of cucumber and paprika. The sensors were placed at 4, 8, 12, and 16 mm from the bottom of the container. Both cucumber and paprika did not show any significant difference in growth and yield among the treatments. However, placing the sensor at 4 mm seemed to be the best in order to prevent over-supply of water at the beginning of the day.