• Title/Summary/Keyword: Sensor based

Search Result 10,190, Processing Time 0.045 seconds

A Study on The Thickness Shrinkage of Injection Molded Parts with The Variation of Injection Mold Core and Molding Materials (사출금형코어 및 성형수지 변화에 따른 두께 방향 수축률에 관한 연구)

  • Shin, Sung-Hyun;Jeong, Eui-Chul;Kim, Mi-Ae;Chae, Bo-Hye;Son, Jung-Eon;Kim, Sang-Yoon;Yoon, Kyung-Hwan;Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.17-21
    • /
    • 2019
  • In this study, selective laser sintered 3D printing mold core and metal core were used to investigate the difference of the thickness shrinkage from the gate of the injection molded part at a constant interval. SLS 3D printing mold core was made of nylon-based PA2200 powder and the metal core was manufactured by conventional machining method. As the PA2200 powder material has low strength, thermal conductivity and high specific heat characteristics compared with metal, molding conditions were set with the consideration of molten temperature and injection pressure. Crystalline resin(PP) and amorphous resin(PS) with low melting temperature and viscosity were selected for the injection molding experiment. Cooling time for processing condition was selected by checking the temperature change of the cores with a cavity temperature sensor. The cooling time of the 3D printing core was required a longer time than that of the metal core. The thickness shrinkage of the molded part compared to the core depth was measured from the gate by a constant interval. It was shown that the thickness shrinkage of the 3D printing core was 2.02 ~ 4.34% larger than that of metal core. In additions, in the case of metal core, thickness shrinkage was increased with distance from the gate, on the contrary, in the case of polymer core showed reversed aspect.

Effect of Simulator Sickness Caused by Head-mounted Display on the Stability of the Pupillary Rhythm (머리착용 디스플레이에 의해 유발된 멀미 증상이 동공 리듬의 안정성에 미치는 영향)

  • Park, Sangin;Lee, Don Won;Mun, Sungchul;Kim, Hong-Ik;Whang, Mincheol
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.43-54
    • /
    • 2018
  • The aim of this study is to determine the effect of motion sickness on pupil rhythm. Sixteen volunteers of both genders (8 male, 8 female, mean age $25.67{\pm}2.43$ years) experienced VR contents in both 2D and HMD versions for 15 minutes, and their pupillary rhythms were compared. The irregular pattern of the pupillary rhythms, as demonstrated by increasing mean pupil diameter (mPD) and standard deviation of the pupil diameter (sPD), revealed motion sickness after experiencing HMD condition. The pupillary response is strongly related to the cognitive load, and the motion sickness can be interpreted as a change in the cognitive load caused by the increasing volume of visual information that must be processed and the conflict or inconsistency between different sensory modalities. The method proposed in this study could be a non-contact measurement method for the monitoring of motion sickness using a web-camera rather than previous sensor-based methods.

Security issues and requirements for cloud-based u-Healthcare System (클라우드기반 u-헬스케어 시스템을 위한 보안 이슈 및 요구사항 분석)

  • Lee, Young Sil;Kim, TaeYong;Lee, HoonJae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.299-302
    • /
    • 2014
  • Due to the convergence between digital devices and the development of wireless communication technology, bit-signal sensor miniaturization, building an Electronic Medical Record (EMR) which is a digital version of a paper chart that contains all of a patient's medical history and the information of Electronic Health Record (EHR), Ubiquitous healthcare (u-Healthcare) that can monitor their health status and provide personal healthcare service anytime and anywhere. Also, the appearance of cloud computing technology is one of the factors that accelerate the development of u-healthcare service. However, if the individual information to be used maliciously during the u-healthcare service utilization, leads to serious problems directly related to the individual's life because if it goes beyond the level of simple health screening and treatment, it may not provide accurate and reliable healthcare services. For this reason, we analyzed a variety of security issues related to u-healthcare service in cloud computing environment and described about directions of secure health information sharing system construction. In addition, we suggest the future developmental direction for th activation of u-healthcare industry.

  • PDF

Evaluation of Resolution of UAV-Image Using Circular Target (Circular target을 이용한 무인항공영상의 해상도 평가)

  • Lee, Jae-One;Sung, Sang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.474-480
    • /
    • 2019
  • We propose a method to evaluate a Modulation Transfer Function (MTF) using a circular target. In addition, a MATLAB GUI-based resolution analysis tool was developed to enhance the reliability of UAV image quality and the efficiency of the work. For this purpose, images were taken with an FC-6310 during flights at altitudes of 80 m, 120 m, and 150 m and by an iXM-100 at altitudes of 150 m, 200 m, and 400 m. The MTFs of UAV images were compared with traditional photogrammetry by measuring and analyzing MTFs on images taken by the UltraCAM Eagle Mark-2 sensor at a flight altitude of 1000 m. The results show that ${\sigma}MTF$ of the FC-6310 were 0.431(80 m), 0.524(120 m), and 0.699(150 m), and those of the iXM-100 were 0.332(150 m), 0.393(200 m), and 0.631(400 m), respectively. At the altitude of 150 m, the image quality of the iXM-100, which has a high-performance camera, was very high, and the effect of the camera performance on the image quality was confirmed. In addition, the ${\sigma}MTF$ of the UltraCAM Eagle Mark-2 was 0.711 due to the high flight altitude. This was the worst value among all UAV images. However, the ${\sigma}MTF$ of the FC-6310 at 150-m altitude was 0.699, which is almost the same as that of a manned aerial image.

Comparison of Visualization Enhancement Techniques for Himawari-8 / AHI-based True Color Image Production (Himawari-8/AHI 기반 True color 영상 생산을 위한 시각화 향상 기법 비교 연구)

  • Han, Hyeon-Gyeong;Lee, Kyeong-Sang;Choi, Sungwon;Seo, Minji;Jin, Donghyun;Seong, Noh-hun;Jung, Daeseong;Kim, Honghee;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.483-489
    • /
    • 2019
  • True color images display colors similar to natural colors. This has the advantage that it is possible to monitor rapidly the complex earth atmosphere phenomenon and the change of the surface type. Currently, various organizations are producing true color images. In Korea, it is necessary to produce true color images by replacing generations with next generation weather satellites. Therefore, in this study, visual enhancement for true color image production was performed using Top of Atmosphere (TOA) data of Advanced Himawari Imager (AHI) sensor mounted on Himawari-8 satellite. In order to improve the visualization, we performed two methods of Nonlinear enhancement and Histogram equalization. As a result, Histogram equalization showed a strong bluish image in the region over $70^{\circ}$ Solar Zenith Angle (SZA) compared to the Nonlinear enhancement and nonlinear enhancement technique showed a reddish vegetation area.

Low-Voltage EM(Elasto-Magnetic) Sensing Technique for Tensile Force Management of PSC(Prestressed Concrete) Internal Tendon (PSC 내부 텐던의 긴장력 관리를 위한 저전압 EM 센싱 기법)

  • Park, Jihwan;Kim, Junkyeong;Eum, Ki-Young;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.2
    • /
    • pp.87-92
    • /
    • 2019
  • In this paper, we have verified a low-voltage EM(elasto-magnetic) sensing technique for tensile force management of PSC(prestressed concrete) internal tendon in order to apply the technique to actual construction sites where stable power supply is difficult. From observation of past domestic and overseas PSC structural accident cases, it was found that PS tension is very important to maintain structural stability. In this paper, we have tried to measure the tensile force from a magnetic hysteresis curve through EM sensors according to voltage value by using relation between magnetostriction and stress of ferromagnetic material based on elastic-magnetic theory. For this purpose, EM sensor of double cylindrical coil type was fabricated and tensile force test equipment for PS tendon using hydraulic tensioning device was constructed. The experiment was conducted to confirm relationship between changes of permeability and tensile force from the measurement results of the maximum / minimum voltage amount. The change of magnetic hysteresis curve with magnitude of tensile force was also measured by reducing amount of voltage step by step. As a result, the slope of estimation equation in accordance with magnitude of magnetic field decreases with the voltage reduction. But it was confirmed a similar pattern of change of magnetic permeability for the magnetic hysteresis loop. So, in this study, it is considered that it is possible to manage the tensions of PSC internal tendon using EM sensing technique in low-voltage state.

Estimation of the Dimensions of Horticultural Products and the Mean Plant Height of Plug Seedlings Using Three-Dimensional Images (3차원 영상을 이용한 원예산물의 크기와 플러그묘의 평균초장 추정)

  • Jang, Dong Hwa;Kim, Hyeon Tae;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.358-365
    • /
    • 2019
  • This study was conducted to estimate the dimensions of horticultural products and the mean plant height of plug seedlings using three-dimensional (3D) images. Two types of camera, a ToF camera and a stereo-vision camera, were used to acquire 3D images for horticultural products and plug seedlings. The errors calculated from the ToF images for dimensions of horticultural products and mean height of plug seedlings were lower than those predicted from stereo-vision images. A new indicator was defined for determining the mean plant height of plug seedlings. Except for watermelon with tap, the errors of circumference and height of horticultural products were 0.0-3.0% and 0.0-4.7%, respectively. Also, the error of mean plant height for plug seedlings was 0.0-5.5%. The results revealed that 3D images can be utilized to estimate accurately the dimensions of horticultural products and the plant height of plug seedlings. Moreover, our method is potentially applicable for segmenting objects and for removing outliers from the point cloud data based on the 3D images of horticultural crops.

A Study on the Utilization of SAR Microsatellite Constellation for Ship Detection (선박탐지를 위한 초소형 SAR 군집위성 활용방안 연구)

  • Kim, Yunjee;Kang, Ki-mook
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.627-636
    • /
    • 2021
  • Although many studies on ship detection using synthetic aperture radar (SAR) satellite images are being conducted around the world, there are still very few employing SAR microsatellites, as most of the microsatellites are optical satellites. Recently, the ICEYE and Capella Space have embarked on the development of microsatellites with SAR sensor, and similar projects are being initiated globally in line with the flow of the new space era [e.g., for the ICEYE: 18 satellites (~2021); Capella Space: 36 satellites (~2023); and the Coast Guard SAR: 32 satellites in the early development stage]. In preparation for these new systems, it is important to review the SAR microsatellite system and the recent advances in this technology. Accordingly, in this paper, the current status and characteristics of optical and SAR microsatellite constellation operation are described, and studies using them are investigated. In addition, based on the status and characteristics of the representative SAR microsatellites, specifically the ICEYE and Capella systems, methods for using SAR microsatellite data for ship detection applications are described. Our results confirm that the SAR microsatellites operate as a constellation and have the advantages of short revisit cycles and quick provision of high-resolution images. With this technology, we expect SAR microsatellites to contribute greatly to the monitoring a wide-area target vessel, in which the spatiotemporal resolution of the imagery is especially important.

Iterative Precision Geometric Correction for High-Resolution Satellite Images (고해상도 위성영상의 반복 정밀 기하보정)

  • Son, Jong-Hwan;Yoon, Wansang;Kim, Taejung;Rhee, Sooahm
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.431-447
    • /
    • 2021
  • Recently, the use of high-resolution satellites is increasing in many areas. In order to supply useful satellite images stably, it is necessary to establish automatic precision geometric correction technic. Geometric correction is the process that corrected geometric errors of satellite imagery based on the GCP (Ground Control Point), which is correspondence point between accurate ground coordinates and image coordinates. Therefore, in the automatic geometric correction process, it is the key to acquire high-quality GCPs automatically. In this paper, we proposed iterative precision geometry correction method. we constructed an image pyramid and repeatedly performed GCP chip matching, outlier detection, and precision sensor modeling in each layer of the image pyramid. Through this method, we were able to acquire high-quality GCPs automatically. we then improved the performance of geometric correction of high-resolution satellite images. To analyze the performance of the proposed method, we used KOMPSAT-3 and 3A Level 1R 8 scenes. As a result of the experiment, the proposed method showed the geometric correction accuracy of 1.5 pixels on average and a maximum of 2 pixels.

Development of Synthetic Signal Generator and Simulator for Performance Evaluation in Multiple Sonobuoy System (다중 소노부이 체계의 신호합성기 및 성능검증용 시뮬레이터 개발)

  • Lee, Su Hyoung;Park, Sang Bae;Han, Sang-Gyu;Kown, Bum Soo
    • Journal of the Korea Society for Simulation
    • /
    • v.30 no.2
    • /
    • pp.11-22
    • /
    • 2021
  • Sonobuoy is widely used as a very important sensor in combat management system using P-3 patrol aircraft due to its advantages of rapid searching into wide exploration range. It is necessary to verify the performance of developed sonobuoy system using various maritime test data in order to be successfully applied in combat management system. But it is difficult to acquire various real maritime data because it needs much time and effort. Therefore we have developed in this paper a synthetic signal generator and a simulator that they can verify the performance of sonobuoy system and evaluate its operational effectiveness without conducting maritime test. We have synthesized target signals based on the characteristics of underwater sound sources, and then developed the synthesized signal generator which consider to sound propagation etc. like as underwater environment. And in the simulator development we use a HMI technique to enhance the convenience of operator, and design to verify the performance of sonobuoy system. The developed signal generator and simulator can be used as useful tools to evaluate the operational effectiveness such as optimal deployment of sonobuoy in combat management system using P-3 patrol aircraft.