• 제목/요약/키워드: Sensor Sensitivity

검색결과 1,892건 처리시간 0.026초

Experimental studies on the diesel engine urea-SCR system using a double NOx sensor system

  • Tang, Wei;Cai, Yixi;Wang, Jun
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.397-402
    • /
    • 2015
  • SCR has been popularly approved as one of the most effective means for NOx emission control in heavy-duty and medium-duty vehicles currently. However, high urea dosing would lead to ammonia slip. And $NH_3$ sensor for vehicle emission applications has not been popularly used in real applications. This paper presents experimental studies on the diesel engine urea-SCR system by using a double NOx sensor system that is arranged in the downstream of the SCR catalyst based on ammonia cross-sensitivity. It was shown that the NOx conversion efficiency rised as $NH_3/NOx$ increases and the ammonia slip started from the $NH_3/NOx$ equal to 1.4. The increase of temperature caused high improvement of the SCR reaction rate while the space velocity had no obvious change. The ammonia slip was in advance as catalyst temperature or space velocity increase and the ammonia storage reduced as catalyst temperature or space velocity increase. The NOx real-time conversion efficiency rised as the ammonia accumulative storage increase and reached the maximum value gradually.

과부하 방지용 마이크로머시닝 세라믹 박막형 압력센서의 제작 (The Fabrication of a Micromachined Ceramic Thin-Film Pressure Sensor with High Overpressure Tolerance)

  • 임병권;최성규;이종춘;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.731-734
    • /
    • 2002
  • This paper describes on the fabrication and characteristics of a ceramic thin-film pressure sensor based on Ta-N strain gauges for harsh environment applications. The Ta-N thin-film strain gauges are sputter deposited onto a micromachined Si diaphragms with buried cavity for overpressure protectors. The proposed device takes advantages of the good mechanical properties of single crystalline Si as diaphragms fabricated by SDB and electrochemical etch-stop technology, and in order to extend the operating temperature range, it incorporates relatively the high resistance, stability and gauge factor of Ta-N thin-films. The fabricated pressure sensor presents a low temperature coefficient of resistance, high sensitivity, low non-linearity and excellent temperature stability. The sensitivity is $1.097{\sim}1.21mV/V{\cdot}kgf/cm^2$ in the temperature range of $25{\sim}200^{\circ}C$ and the maximum non-linearity is 0.43 %FS.

  • PDF

2축 마이크로 플럭스게이트 센서 제작을 통한 전자 나침반 개발 (Development of Electronic Compass Using 2-Axis Micro Fluxgate Sensor)

  • 박해석;심동식;나경원;황준식;최상언
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.418-423
    • /
    • 2003
  • This paper describes an electronic compass using micromachined X- and Y-axis micro fluxgate sensors which were perpendicularly aligned each other to measure X- and Y-axis magnetic fields respectively. The fluxgate sensor was composed of rectangular-ring shaped magnetic core and solenoid excitation(49 turns) and pick-up(46 turns) coils. Excitation and pick-up coil patterns which were formed opposite to each other wound the magnetic core alternatively to improve the sensitivity and to excite the magnetic core in an optimal condition with reduced excitation current. The magnetic core has DC effective permeability of ~1000 and coercive field of ~0.1 Oe. The magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. To decrease the difference of induced second harmonic voltages from X- and Y-axis, excitation condition of 2.8 $V_{P-P}$ and 1.2 MHz square wave was selected. Excellent linear response over the range of -100 $\mu$T to +100 $\mu$T was obtained with 210 V/T sensitivity. The size of each micro fluxgate sensor excluding pad region was about 2.6${\times}$1.7 $mm^2$ and the power consumption was estimated to be 14 mW.W.

측면연마된 단일모드 광섬유와 폴리머 평면도파로 결합기를 이용한 고감도 온도센서 (High-sensitivity temperature sensor using the side polished single mode fiber and polymer planar waveguide coupler)

  • 정웅규;김상우;김광택;김응수;유윤식;강신원
    • 대한전자공학회논문지SD
    • /
    • 제39권1호
    • /
    • pp.39-46
    • /
    • 2002
  • 단일모드 광섬유와 평면도파로 결합기의 파장선택성을 이용한 고감도 온도센서를 구현하였다. 폴리머 평면도파로의 높은 열광학 효과에 의하여 결합기의 공진파장이 -3.43㎚/℃ 정도로 매우 민감하게 이동함을 관찰할 수 있었다. 소자의 편광의존성을 줄이고 온도에 대한 감도를 증가시키기 위한 설계 기법을 제시하였다.

가열모드에 따른 열식 질량유량센서의 설계 해석 (Numerical Analysis on the Design of a Thermal Mass Air Flow Sensor with Various Heating Modes)

  • 전홍규;이준식;박병규
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.876-883
    • /
    • 2007
  • Numerical simulations are conducted for the design of a micro thermal mass air flow sensor (MAFS), which consists of a microfabricated heater and thermopiles on the silicon-nitride ($Si_3N_4$) thin membrane structure. It is important to find the proper locations of these thermal elements in the design of MAFS with improved sensitivity. Three heating modes of the micro-heater are considered: constant temperature, constant power and heating pulses. The analyses are focused on the membrane temperature profile near the sensing section. Considered are the practical flow velocities, ranging from 3 m/s to 35 m/s, and the corresponding Reynolds numbers from 1000 to 10000. The results show that one of optimum sensing locations is about $100{\mu}m$ away from the microheater. It is concluded that the heating mode and configurations of thermal elements are the main factors for the MAFS with higher sensitivity.

전도성 고분자가 첨가된 생체 모방형 분자 각인 고분자 테르펜 센서 (Biomimetic MIP Terpene Sensors Adding Conductive Polymers)

  • 정재훈;이성필
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.345-351
    • /
    • 2012
  • Biomimetic terpene sensors which have high sensitivity and stability have been fabricated using moleculary imprinted polymer (MIP) technology. Since it is impossible to make a resistive type sensor due to the high resistance of MIP, we improved the sensor by adding conductive polymers. We investigated the sensitivity of resistive type sensors with nano particles depending on the amount of conductive polymers. The MIP membrane contained the methacrylic acid as functional monomer and ethylene glycol dimethacrylate as cross linker, which formed specific cavities originated by the target terpene molecules. The mixture of MIP and the conductive polymer was coated on the patterns of interdigit electrodes on the alumina substrate. The fabricated sensors showed their highest specific sensitivities exposed to 500 ppm target gases : limonene 0.055 at 40% of amount of conductive polymers and geraniol $5.84{\times}10^{-4}$ at 20% of amount of conductive polymers. In conclusion, we found that the terpene sensors are affected by the target molecules, functional monomers and the conductive polymers.

SiC 쇼트키 장벽 다이오드를 이용한 CO 가스 감지 특성에 관한 연구 (A study on CO gas sensing characteristics using SiC Schottky diodes)

  • 김창교;노일호;조남인;유홍진;기창진
    • 한국산학기술학회논문지
    • /
    • 제5권1호
    • /
    • pp.83-86
    • /
    • 2004
  • 고온용 마이크로 전자소자를 이용한 일산화탄소 가스센서를 개발하였다. 100-300℃의 영역에서 가스 감지 특성을 조사하였다. 센서의 가스 감도는 높고, 감지속도는 빠르고 센서는 재현성을 보여 주었다. Pt-SiC 및 Pt-SnO₂ 다이오드는 표준 반도체 공정을 이용하여 제작하였다. CO 가스 감지 특성은 정상상태 및 과도 상태의 조건아래에서 Ⅰ-Ⅴ 및 △Ⅰ-t법을 이용하여 CO 가스 농도와 온도의 함수로서 분석하였다. Pt-SnO₂촉매 층을 갖는 소자의 가스 감도가 Pt 게이트만으로 이루어진 소자보다 높았다. 실험 결과는 SnO₂층이 Pt막의 촉매 반응을 향상시키는 것을 보여주었다.

  • PDF

포화자성코어를 이용한 직류전류측정 트랜스듀서 (DC Current Transducer Using Saturable Magnetic Cores)

  • 박영태;정재갑;강전홍;유권상;유광민
    • 한국자기학회지
    • /
    • 제14권4호
    • /
    • pp.138-142
    • /
    • 2004
  • 본 연구는 누설전류와 같은 직류 저 전류를 측정하기 위한 센서 개발에 관한 것이다. 2개의 동일한 링 형태의 자성체 코어를 이용하여 전류센서를 개발하였으며 센서에 대한 특성과 불확도에 대하여 기술하였다. 이 트랜스듀서는 변성기형의 센서, 피크검출기, 기준저주파발진기 그리고 고조파를 함유한 센서의 출력을 측정할 수 있는 정밀 측정회로들로 구성되며 DC 2A까지 측정할 수 있다. 분해능과 감도는 0.㎃. 10㎷/㎃로. 각각 평가되었다.

압저항체에서 발생하는 잔류응력이 저항변화율 분포도에 미치는 영향성 평가 (The evaluation of the effect of residual stress induced in piezoresistor on resistance change ratio distribution)

  • 심재준;한근조;이성욱;이상석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.790-793
    • /
    • 2005
  • In these days, the piezoresistive material has been applied to various sensors in order to measure the change of physical quantities. But the relationship between the sensitivity of a sensor and the position and size of piezoresistor has rarely been studied. Therefore, this paper was focused on the effect of residual stress induced in piezoresistor on the distribution of resistance change ratio and supposed the feasible position of piezoresistor. The resulting are following; The tensile residual stress in the vicinity of piezoresistor decreased the value of resistance change ratio and could not effect on all the area of diaphragm but local area around the piezoresistor. Also, the piezoresistor in the diaphragm type pressure sensor with boss should fabricate in the edge of boss in order to increase the sensitivity of pressure sensor.

  • PDF

가스센서 어레이를 이용한 산림환경 내 치유물질 측정시스템을 통한 자연적 휘발성 유기화합물(NVOCs)과 인위적 휘발성 유기화합물(AVOCs) 분류 (Classification of NOVCs and AVOCS for Healing Substance Measurement System Based on Gas Sensors Array in Forest Environment)

  • 유준부;변형기
    • 센서학회지
    • /
    • 제32권2호
    • /
    • pp.95-99
    • /
    • 2023
  • Forest healing is an activity that enhances immunity and human health using various elements of nature, such as fragrance and scenery. Particularly, phytoncide composed of terpene, a natural volatile substance emitted by forest plants, activates the immune function and is an important raw material in health-related products, such as antibacterial and insect repellents. Moreover, phytoncide is used as a measure to evaluate the impact of the forest atmosphere on the human body. This study aims to implement a highly sensitive gas sensor system that can measure phytoncide in real-time, which is an essential element for realizing a forest healing environment. A gas generation apparatus was implemented by using an adsorption tube in consideration of filed applicability in a laboratory atmosphere to enable the measurement of α-pinene and limonene, which are among the main components of phytoncide. Throughout the experimental trials, the sensitivity of gas sensor arrays to α-pinene and limonene was confirmed. In addition, the classification results demonstrated the AVOCs and NVOCs can be well discriminated using PCA. The primary results confirmed the possibility of developing a high-sensitivity gas sensor system for phytoncide sensing in real time.