• 제목/요약/키워드: Sensor Sensitivity

검색결과 1,892건 처리시간 0.023초

높은 동적영역을 갖기 위한 정전용량형 센서의 최적화 (Optimization of a capacitive sensor for high dynamic range)

  • 강대실;김무진;문원규
    • 센서학회지
    • /
    • 제19권2호
    • /
    • pp.92-98
    • /
    • 2010
  • The capacitive sensor has a simple structure, compact size and low cost, but a small dynamic range. The small range is caused by use of gap variation. If the sensor takes area variation type with one plate moving horizontally, it can have a large measurable range. While the area variation has relatively low sensitivity, some studies have found methods to improve the sensitivity. Even though the methods are effective, parameters of the results are limited and 2 dimensional. This study provides more practical and 3 dimensional analysis and suggests relations between parameters. Using the results, the optimized design parameters of a high dynamic range capacitive sensor can be found.

Disposable in-field electrochemical potable sensor system for free available chlorine (FAC) detection

  • Chang, Seung-Cheol;Park, Deog-Su
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.449-456
    • /
    • 2007
  • The work described in this study concerns the development of a disposable amperometric sensor for the electrochemical detection of a well-known aqueous pollutant, free available chlorine (FAC). The FAC sensor developed used screen printed carbon electrodes (SPCEs) coupled with immobilised syringaldazine, commonly used as an indicator in photometric FAC detection, which was directly immobilised on the surface of SPCEs using a photopolymer PVA-SbQ. To enable in-field analysis of FAC, a prototype hand-held electrochemical analyzer has been developed to withstand the environment with its rugged design and environmentally sealed connections; it operates from two PP3 (9 volt) batteries and is comparable in accuracy and sensitivity to commercial bench top systems. The sensitivity of the FAC sensor developed was $3.5{\;}nA{\mu}M^{-1}cm^{-2}$ and the detection limit for FAC was found to be $2.0{\;}{\mu}M$.

이산화탄소 검출을 위한 고감도 비분산 적외선 가스센서의 광도파관 구조 설계 (Optical waveguide structure design of Non-dispersive Infrared (NDIR) CO2 gas sensor for high-sensitivity)

  • 윤지영;이준엽;도남곤;정대웅
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.331-336
    • /
    • 2021
  • The Non-dispersive Infrared (NDIR) gas sensor has high selectivity, measurement reliability, and long lifespan. Thus, even though the NDIR gas sensor is expensive, it is still widely used for carbon dioxide (CO2) detection. In this study, to reduce the cost of the NDIR CO2 gas sensor, we proposed the new optical waveguide structure design based on ready-made gas pipes that can improve the sensitivity by increasing the initial light intensity. The new optical waveguide design is a structure in which a part of the optical waveguide filter is inclined to increase the transmittance of the filter, and a parabolic mirror is installed at the rear end of the filter to focus the infrared rays passing through the filter to the detector. In order to examine the output characteristics of the new optical waveguide structure design, optical simulation was performed for two types of IR-source. As a result, the new optical waveguide structure can improve the sensitivity of the NDIR CO2 gas sensor by making the infrared rays perpendicular to the filter, increasing the filter transmittance.

SnO2 나노와이어를 이용한 저온동작 고감도 고선택성 NO2 가스센서 (Highly sensitive and selective NO2 gas sensor at low temperature based on SnO2 nanowire network)

  • 김유종;박소영;이정석;이세형;우경완;이상현;이문석
    • 센서학회지
    • /
    • 제30권3호
    • /
    • pp.175-180
    • /
    • 2021
  • In this paper, methods for improving the sensitivity of gas sensors to NO2 gas are presented. A gas sensor was fabricated based on an SnO2 nanowire network using the vapor-phase-growth method. In the gas sensor, the Au electrode was replaced with a fluorinedoped tin oxide (FTO) electrode, to achieve high sensitivity at low temperatures and concentrations. The gas sensor with the FTO electrode was more sensitive to NO2 gas than the sensor with the Au electrode: notably, both sensors were based on typical SnO2 nanowire network. When the Au electrode was replaced by the FTO electrode, the sensitivity improved, as the contact resistance decreased and the surface-to-volume ratio increased. The morphological features of the fabricated gas sensor were characterized in detail via field-emission scanning electron microscopy and X-ray diffraction analysis.

POST-LAUNCH RADIOMETRIC CALIBRATION OF KOMPSAT2 HIGH RESOLUTION IMAGE

  • Yoon, Jong-Suk;Lee, Kyu-Sung;Chi, Jun-Hwa;Lee, Dong-Han
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.402-405
    • /
    • 2006
  • Radiometric calibration of optical image data is necessary to convert raw digital number (DN) value of each pixel into a physically meaningful measurement (radiance). To extract rather quantitative information regarding biophysical characteristics of the earth surface materials, radiometric calibration is often essential procedure. A sensor detects the radiation of sunlight interacted atmospheric constituents. Therefore, the amount of the energy reaching at the sensor is quite different from the initial amount reflected from the surface. To achieve the target reflectance after atmospheric correct, an initial step is to convert DN value to at-sensor radiance. A linear model, the simplest radiometric model, is applied to averaged spectral radiance for this conversion. This study purposes to analyze the sensitivity of several factors affecting on radiance for carrying out absolute radiometric calibration of panchromatic images from KOMPSAT2 launched at July, 2006. MODTRAN is used to calculate radiance at sensor and reflectance of target is measured by a portable spectro-radiometer at the same time the satellite is passing the target for the radiometric calibration. As using different contents of materials composing of atmosphere, the differences of radiance are investigated. Because the spectral sensitivity of panchromatic images of KOMPSAT2 ranges from 500 to 900 nm, the materials causing scattering in visible range are mainly considered to analyze the sensitivity. According to the verified sensitivity, direct measurement can be recommenced for absolute radiometric calibration.

  • PDF

높은 민감도 및 우수한 피부 통기성을 가진 마이크로 섬유 기반의 직물형 유연 압력 센서 (Microfiber-based Textile Pressure Sensor with High Sensitivity and Skin-breathability)

  • 한강토;최장희;임정우;공혜영;배근열
    • 한국염색가공학회지
    • /
    • 제35권3호
    • /
    • pp.179-187
    • /
    • 2023
  • In this study, we developed a microfiber-based flexible pressure sensor with high sensitivity and excellent skin breathability. A nonwoven fabric composed of microfibers was prepared by electrospinning, which resulted in excellent moisture permeability of the sensor (143 g∙m-2∙h-1). In particular, high-pressure sensitivity (0.36 kPa-1) was achieved by introducing submicron structures on the microfiber surface by controlling the ambient humidity during electrospinning. The fabrication technology of the microfiber-based flexible pressure sensors reported in this study is expected to contribute to the commercialization of flexible pressure sensors applicable to long-term wearable health monitoring as well as virtual/augmented reality and electronic skin applications.

Fiber-Optic Temperature Sensor Based on Single Mode Fused Fiber Coupler

  • Kim, Kwang-Taek;Park, Kiu-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.152-156
    • /
    • 2008
  • This paper reports a fiber-optic temperature sensor using a single mode fused fiber coupler incorporating a thermo-optic external medium. The spectral transmission was altered by changing the refractive index of the external thermo-optic medium. A theoretical and experimental investigation was carried out with the aim of achieving high sensitivity. The measured sensitivity for the environmental temperature was as high as -1.5 $nm/^{\circ}C$.

A Particulate Matter Sensor with Groove Electrode for Real-Time Diesel Engine On-Board Diagnostics

  • Kim, S.;Kim, Y.;Lee, J.;Lim, S.;Min, K.;Chun, K.
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.191-196
    • /
    • 2013
  • A particulate matter sensor fabricated by MEMS process is proposed. It is developed to accommodate Euro6 on-board diagnostics regulation for diesel automobile. In the regulation, emission of diesel particulate matter is restricted to 9 mg/km. Particulate matter sensor is designed to use induced charges by charged particulate matter. To increase sensitivity of the sensor, groove is formed on sensor surface because wider surface area generates more induced charges. Sensitivity of the sensor is measured 10.6 mV/(mg/km) and the sensor shows good linearity up to 15.7 mg/km. Also its minimum detectable range is about 0.25 mg/km. It is suitable to detect failure of a diesel particulate filter which should filter particulate matter more than 9 mg/km. For removing accumulated particulate matter on the sensor which can disturb normal operation, platinum heater is designed on the backside of the sensor. The developed sensor can sense very low amount of particulate matter from exhaust gas in real-time with good linearity.

폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가 (Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor)

  • 임봉빈;이석준;김선태
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

효모균을 이용한 BOD Biosensor (Yeast Loading BOD Biosensor)

  • 김말남
    • 한국균학회지
    • /
    • 제23권4호통권75호
    • /
    • pp.354-358
    • /
    • 1995
  • 용존 유기물의 농도를 BOD로 신속히 측정하여 폐수처리 공정에 feed back할 수 있는 Yeast BOD sensor 를 제작하여 BOD 측정의 거동을 조사하였다. BOD sensor의 감응도는 yeast의 활성이 가장 높은 pH 7.0 및 온도 $30^{\circ}C$에서 가장 높게 나타났다. Sensor에 충전되는 효모의 양도 감응도에 영향을 미치며 투석막 단위면적당 $ 0.14\;mg/cm^2$가 최적의 균체량이었다. 오염물질의 종류에 따라 BOD sensor의 출력 신호가 다르게 나타났으며 각각의 오염물질 속에 효모균를 전처리 시킨 후 sensor에 충전할 경우 sensor 의 감응도가 크게 증가하였다.

  • PDF