• 제목/요약/키워드: Sensor Plate

검색결과 462건 처리시간 0.032초

가상 탐지자 배열 모델을 이용한 직사각형 판에서 A0 램파 모드 시간반전과정 모사 (Simulating a Time Reversal Process for A0 Lamb Wave Mode on a Rectangular Plate Using a Virtual Sensor Array Model)

  • 박현우
    • 한국소음진동공학회논문집
    • /
    • 제20권5호
    • /
    • pp.460-469
    • /
    • 2010
  • This paper presents the analysis of a time reversal process for $A_0$ Lamb wave mode($A_0$ mode) on a rectangular plate. The dispersion characteristic equation of the $A_0$ mode is approximated using the Timoshenko beam theory. A virtual sensor array model is developed to consider the effects of reflections occurring on the plate boundary on the time reversal process. The time reversal process is formulated in the frequency domain using the virtual sensor array model. The reconstructed signal is obtained in the time domain through an inverse fast Fourier transform. The validity of the proposed method is demonstrated through the comparison to the numerical simulation results computed by the finite element analysis.

광섬유 센서를 이용한 구조물의 열변형 및 온도 측정 (Thermal Strain and Temperature Measurements of Structures by Using Fiber-Optic Sensors)

  • 강동훈;강현규;류치영;홍창선;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.184-189
    • /
    • 2000
  • Two types of fiber-optic sensors, EFPI(extrinsic Fabry-Perot interferometer) and FBG(fiber Bragg grating), have been investigated for measurement of thermal strain and temperature. The EFPI sensor is only for measurement of thermal strain and the FBG sensor is for simultaneous measurement of thermal strain and temperature. FBG temperature sensor was developed to measure strain-independent temperature. This sensor configuration consists of a single-fiber Bragg grating and capillary tube which makes it isolated from external strain. This sensor can then be used to compensate for the temperature cross sensitivity of a FBG strain sensor. These sensors are demonstrated by embedding them into a graphite/epoxy composite plate and by attaching them on aluminum rod and unsymmetric graphitelepoxy composite plate. All the tests were conducted in a thermal chamber with the temperature range $20-100^{\circ}C$. Results of strain measurements by fiber-optic sensors are compared with that from conventional resistive foil gauge attached on the surface.

  • PDF

탄환 충격파 측정용 방수 음향센서 개발 (Development of Waterproof Acoustic Sensor for Shockwave Measurement)

  • 허신;이덕규
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.318-322
    • /
    • 2019
  • In shooting training, an impact point identification system that uses the impact wave of the bullet to check the impact point in the target plate has been recently used. Acoustic sensors used in these systems must be able to detect shock waves of high sound pressure levels and be both waterproof and dustproof for rainy weather and dusty environments, respectively. In this study, membranes with excellent waterproof, dustproof, and sound transmitting characteristics were selected through a characteristics test; a protection cap was installed to install the selected materials. After coupling the produced protection cap to the acoustic sensor housing, the sensitivity and phase characteristics of the acoustic sensor were checked. Through the waterproof and dustproof test, the performances of its sensitivity and phase characteristics were confirmed. Finally, the normal shockwave of a 5.56 mm diameter bullet was measured using a shockwave detection signal collecting plate equipped with a prototype of the acoustic sensor at a 100 m firing range.

Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement

  • Park, Young Jae;Jang, Ho Young;Kim, Kwon Hoi;Hwang, Dong Ki;Lee, Suk Min
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권3호
    • /
    • pp.311-320
    • /
    • 2022
  • Objective: To investigate the reliability and validity of static balance measurements using an acceleration sensor and a gyroscope sensor in smart phone inertial sensors. Design: Equivalent control group pretest-posttest. Methods: Subjects were forty five healthy adults aged twenty to fifty-years-old who had no disease that could affect the experiment. After pre-test, all participants wore a waist band with smart phone, and conducted six static balance measurements on the force plate twice for 35 seconds each. To investigate the test-retest reliability of both smart phone inertial sensors, we compared the intra-correlation coefficient (ICC 3, 1) between primary and secondary measurements with the calculated root mean scale-total data. To determine the validity of the two sensors, it was measured simultaneously with force plate, and the comparision was done by Pearson's correlation. Results: The test-retest reliability showed excellent correlation for acceleration sensor, and it also showed excellent to good correlation for gyroscope sensor(p<0.05). The concurrent validity of smartphone inertial sensors showed a mostly poor to fair correlation for tandem-stance and one-leg-stance (p<0.05) and unacceptable correlation for the other postures (p>0.05). The gyroscope sensor showed a fair correlation for most of the RMS-Total data, and the other data also showed poor to fair correlation (p<0.05). Conclusions: The result indicates that both acceleration sensor and gyroscope sensor has good reliability, and that compared to force plate, acceleration sensor has unacceptable or poor correlation, and gyroscope sensor has mostly fair correlation.

MFC 액츄에이터가 부착된 외팔 평판의 능동 진동 제어 (Active Vibration Control of Cantilever Plate Equipped with MFC Actuators)

  • 곽문규;양동호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.533-534
    • /
    • 2013
  • This paper is concerned with the active vibration control of rectangular plate equipped with MFC actuators. To this end, the dynamic model of the rectangular plate bonded with MFC sensors and actuators was derived by means of the Rayleigh-Ritz method. The MFC actuator and sensor were modeled based on the pin-force assumption. The theoretical model was then validated experimentally. The multiinput and multi-output (MIMO) Positive Position Feedback (PPF) controller was designed based on the natural mode shapes and implemented using dSpace system and Simulink. The proposed control algorithm was applied to the cantilever plate having two MFC wafers having both sensor and actuator. Numerical and experimental investigations were carried out. Both theoretical and experimental result shows that the proposed control algorithm can effectively suppress vibrations of cantilever plate.

  • PDF

브래그 격자 센서 시스템을 이용한 복합재 평판 진동의 실험적 해석 (Experimental Analysis on Vibration of Composite Plate by Using FBG Sensor System)

  • 김대현
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.436-441
    • /
    • 2009
  • 광섬유 센서는 구조 건전성 감시 분야에 적용되는 유망한 센서 시스템이다. 특히 광섬유 브래그 격자(FBG) 센서는 본 분야에 있어 가장 각광받는 센서들 중에 하나이다. 이러한 FBG 센서는 브래그 파장의 이 동량을 알아내는 방법에 따라 다양한 시스템 구성이 가능하다. 또한 센서 시스템의 동특성은 이러한 시스템에 의해 결정된다. 본 논문에서는 FBG 센서의 브래그 파장 스팩트럼 최대 경사부에 단일 파장 레이저의 중심 파장을 맞춰 놓을 경우, 센서의 경사도가 센서 감도로 작용할 수 있다는 측정 원리를 이용하였다. 이러한 원리는 전체 측정 범위의 한계는 있지만 높은 민감도를 보장한다. 본 측정 원리의 적용 예로서, FBG 센서를 삽입한 복합재 평판을 오토클래이브를 이용해 제작하고 앞서 설명한 측정 원리를 적용하였다. 첫째로 삽입된 FBG 센서를 이용해 충격 망치로 가격된 복합재 평판의 고유 진동수를 성공적으로 측정하였다. 둘째로 고출력 스피커를 이용해 앞서 측정된 고유진동수 중 하나의 특정 주파수로 복합재 평판을 강제 가진 시켰다. 이때 발생하는 구조 진동을 FBG 센서로 측정하였고 동시에 ESPI 측정 시스템을 이용해 진동 모드 형상 역시 성공적으로 측정하여 복합재 구조물의 동특성을 파악하였다. 따라서, 이러한 두 실험을 통해 FBG 센서 시스템과 ESPI 측정 시스템이 복합재 구조물의 동특성 측정에 매우 유용한 기술임을 증명하였다.

Damage localization in plate-like structure using built-in PZT sensor network

  • Liu, Xinglong;Zhou, Chengxu;Jiang, Zhongwei
    • Smart Structures and Systems
    • /
    • 제9권1호
    • /
    • pp.21-33
    • /
    • 2012
  • In this study, a Lamb-wave based damage detection approach is proposed for damage localization in plate. A sensor network consisting of three PZT wafer type actuators/sensors is used to generate and detect Lamb waves. To minimize the complication resulted from the multimode and dispersive characteristics of Lamb waves, the fundamental symmetric Lamb mode, $S_0$ is selectively generated through designing the excitation frequency of the narrowband input signal. A damage localization algorithm based upon the configuration of the PZT sensor network is developed. Time-frequency analysis method is applied to purify the raw signal and extract damage features. Experimental result obtained from aluminum plate verified the proposed damage localization approach.

대류방식을 이용한 열유속센서의 검정에 관한 연구 (A Study on Calibration of Heat Flux Sensor by using Convective Heat Transfer)

  • 양훈철;송철화;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1358-1363
    • /
    • 2004
  • The objective of this work is to propose calibration facility in which a thin film type heat flux sensor can be calibrated under convective flow condition by using a small wind tunnel with the constant temperature plate condition. A small wind tunnel has been built to produce a boundary layer shear flow above a constant temperature copper plate. 12-independent copper blocks, thin film heaters, insulators and temperature controllers were used to keep the temperature of flat plate constant at a specified temperature. Three commercial thin film-type heat flux sensors were tested. Convective calibrations of these gages were performed over the available heat flux range of $1.4{\sim}2.5kW/m^2$. The uncertainty in the heat flux measurements in the convective-type heat flux calibration facility was ${\pm}2.07%$. Non-dimensional sensitivity is proposed to compare the sensitivity calibrated by manufacturer and that of experiment conducted in this study.

  • PDF

미지물체를 잡기 위한 로봇 손가락의 3축 힘감지센서 설계 및 제작 (Design and fabrication of robot′s finger 3-axis force sensor for grasping an unknown object)

  • 김갑순
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.229-232
    • /
    • 2002
  • This paper describes the development of robot's finger 3-axis force sensor that detects the Fx, Fy, and Fz simultaneously fur stably grasping an unknown object. In order to safely grasp an unknown object using the robot's fingers, they should detect the force of gripping direction and the force of gravity direction, and perform the force control using the detected farces. The 3-axis force sensor that detects the Fx, Fy, and Fz simultaneously should be used for accurately detecting the weight of an unknown object of gravity direction. Thus, in this paper, robot's finger for stably grasping an unknown object is developed. And, the 3-axis farce sensor that detects the Fx, Fy, and Fz simultaneously fur constructing a robot's finger is newly modeled using several parallel-plate beams, and is fabricated. Also, it is calibrated, and evaluated.

  • PDF

Study on the Improvement of Indirect Intra-Oral Dental Digital X-ray Image Sensor with Optical Coupling

  • Whang, Joo-Ho;Chung, Jin-Bum;Kim, Tae-Woo
    • Nuclear Engineering and Technology
    • /
    • 제33권5호
    • /
    • pp.514-525
    • /
    • 2001
  • Optimum characteristics of digital X-ray sensor components were analyzed to develop intra- oral dental digital X-ray image sensor using indirect method. Parametric analysis was carried out to optimize the phosphor thickness and the fiber optic plate (FOP) coupling to charge coupled device (CCD). X-ray absorption and light diffusion in the phosphor layer were analyzed by the Monte Carlo method. Real time X-ray image was obtained with prototype X- ray image sensor using general CCD camera with 1∼10 Ip/mm resolution. It has been previously shown that large resolution degradation in X-ray images was caused by miss alignment of FOP to CCD and optical adhesive selection. In this study, we reported that X-ray image quality was greatly improved by using optimized characteristics of alignment device and phosphor thickness.

  • PDF