Galvanic Sensor System for Detecting the Corrosion Damage of the Steel in Concrete

  • Kim, Jung-Gu;Park, Zin-Taek;Yoo, Ji-Hong;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • 제3권3호
    • /
    • pp.118-126
    • /
    • 2004
  • The correlation between sensor output and corrosion rate of reinforcing steel was evaluated by laboratory electrochemical tests in saturated $Ca(OH)_2$ with 3.5 wt.% NaCl and confirmed in concrete environment. In this paper, two types of electrochemical probes were developed: galvanic cells containing of steel/copper and steel/stainless steel couples. Potentiodynamic test, weight loss measurement, monitoring of open-circuit potential, linear polarization resistance (LPR) measurement and electrochemical impedance spectroscopy (EIS) were used to evaluate the corrosion behavior of steel bar embedded in concrete. Also, galvanic current measurements were conducted to obtain the charge of sensor embedded in concrete. In this study, steel/copper and steel/stainless steel sensors showed a good correlation in simulated concrete solution between sensor output and corrosion rate of steel bar. However, there was no linear relationship between steel/stainless steel sensor output and corrosion rate of steel bar in concrete environment due to the low galvanic current output. Thus, steel/copper sensor is a reliable corrosion monitoring sensor system which can detect corrosion rate of reinforcing steel in concrete structures.

Corrosion Monitoring for Protected Systems using Thin-Film Electrical Resistance (TFER) Sensor

  • Lee, Seong-Min;Li, SeonYeob;Jung, Sung-Won;Kim, YoungGeun;Song, HongSeok;Won, Deok-Soo
    • Corrosion Science and Technology
    • /
    • 제5권3호
    • /
    • pp.112-116
    • /
    • 2006
  • This study has been conducted to monitor the corrosion rate of cathodically protected structure and corrosion inhibited system using multi-line thin-film electrical resistance (TFER) sensor in various environments. The field test data of TFER sensor for the corrosion monitoring of cathodically protected underground pipeline in soil environments and of corrosion inhibited gas heaters were also presented. The sensor was found to be a powerful method to commit the sensitive pick-up of small corrosion rate which can be observed in the cathodically protected and corrosion inhibited systems.

이중보온관 부식감지선의 응력부식파괴에 관한 연구 (A study on Stress Corrosion Cracking of Sensor Wire in Thermally Insulated Underground Pipeline)

  • 최윤제;김정구
    • 한국재료학회지
    • /
    • 제12권2호
    • /
    • pp.103-111
    • /
    • 2002
  • The thermally insulated underground pipelines have been used for district heating system. The sensor wire embedded in the insulation was used for monitoring the insulating resistance between the sensor wire and the pipe. The resistance measurement system detects corrosion of steel pipe under insulation. The corrosion and stress corrosion cracking(SCC) characteristics of sensor wire in synthetic ground water were investigated using the electrochemical methods and constant load SCC tests. The polarization tests were used to study the electrochemical behavior of sensor wire. The sensor wire was passivated at temperatures ranging from 25 to $95^{\circ}C$. However, the applied sensing current larger than passive current resulted in breakdown of passive film. The constant load SCC tests were performed to investigate the effects of applied current and load on the fracture behavior. Stress-corrosion cracks initiated at pits that were produced by sensing current. The growth of the pit involves a tunnelling mechanism, which leads to ductile fracture.

배관의 부식 상태 진단에 사용되는 ER 부식센서의 가속부식환경에서의 신뢰성 평가 (Reliability Evaluation of ER Type Corrosion Sensor for Monitoring Corrosion of Piping System Under Accelerated Corrosion Environment)

  • 황현규;신동호;김헌희;이정형
    • Corrosion Science and Technology
    • /
    • 제20권6호
    • /
    • pp.403-411
    • /
    • 2021
  • In this study, the reliability of a commercial ER-type corrosion sensor was evaluated under an accelerated corrosion environment to verify its suitability for application in monitoring of ship's seawater piping system. A closed-loop pump piping testbed was designed and constructed to compare the wall thickness reduction of the pipe and the response from the sensor. The sensor was attached inside the pipe near the outlet of the pump that was exposed to a 3.5% NaCl solution with or without copper accelerated acetic acid (CASS). The results demonstrated that the presence of CASS significantly increased the corrosivity of the solution as well as the thickness reduction of the pipe, as expected. On the other hand, the corrosion products formed by the solution with CASS were thicker compared with those without CASS. The sensor response to temperature variation was found to be a clear linear relationship for the solution without CASS but there was a non-linear relationship where CASS was present.

A Galvanic Sensor for Monitoring the External and Internal Corrosion Damage of Buried Pipelines

  • Choi, Yoon-Seok;Kim, Jung-Gu;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • 제4권5호
    • /
    • pp.178-190
    • /
    • 2005
  • In order to develop a new corrosion sensor for detecting and monitoring the external and internal corrosion damage of buried pipeline, the electrochemical property of sensors and the correlation of its output to corrosion rate of steel pipe, were evaluated by electrochemical methods in two soils of varying resistivity (5,000 ohm-cm, 10,000 ohm-cm) and synthetic tap water environments. In this paper, two types of galvanic probes were manufactured: copper-pipeline steel (Cu-CS) and stainless steel-pipeline steel (SS-CS). The corrosion behavior in synthetic groundwater and synthetic tap water for the different electrodes was investigated by potentiodynamic test. The comparison of the sensor output and corrosion rates revealed that a linear relationship was found between the probe current and the corrosion rates. In the soil resistivity of $5,000{\Omega}-cm$ and tap water environments, only the Cu-CS probe had a good linear quantitative relationship between the sensor output current and the corrosion rate of pipeline steel. In the case of $10,000{\Omega}-cm$, although the SS-CS probe showed a better linear correlation than that of Cu-CS probe, the Cu-CS probe is more suitable than SS-CS probe due to the high current output.

콘크리트내 염분침투 모니터링을 위한 부식 센서 개발에 관한 기초적 연구 (A Preliminary Study on the Corrosion Monitoring Sensor of Chloride Permeation into Concrete)

  • 조성형;이현석;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.5-7
    • /
    • 2010
  • Corrosion sensors were devised to develop a system whereby the depth of chloride permeation from concrete surfaces can be monitored in cover concrete of reinforced concrete structures. For making sensor which is similar to rebar author uses Screen printer machines, Ag paste and Fe powder. Appropriate portion of Ag and Fe is over 1:2. The resistance of sensors increased as the degree of corrosion increased. And according to cover depth author suggests sensor system which has a demanded cover depth. It was therefore confirmed that the corrosion sensor can monitor chloride permeation by change of resistance.

  • PDF

FE and ANN model of ECS to simulate the pipelines suffer from internal corrosion

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제3권3호
    • /
    • pp.297-314
    • /
    • 2016
  • As the study of internal corrosion of pipeline need a large number of experiments as well as long time, so there is a need for new computational technique to expand the spectrum of the results and to save time. The present work represents a new non-destructive evaluation (NDE) technique for detecting the internal corrosion inside pipeline by evaluating the dielectric properties of steel pipe at room temperature by using electrical capacitance sensor (ECS), then predict the effect of pipeline environment temperature (${\theta}$) on the corrosion rates by designing an efficient artificial neural network (ANN) architecture. ECS consists of number of electrodes mounted on the outer surface of pipeline, the sensor shape, electrode configuration, and the number of electrodes that comprise three key elements of two dimensional capacitance sensors are illustrated. The variation in the dielectric signatures was employed to design electrical capacitance sensor (ECS) with high sensitivity to detect such defects. The rules of 24-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. A feed-forward neural network (FFNN) structure are applied, trained and tested to predict the finite element (FE) results of corrosion rates under room temperature, and then used the trained FFNN to predict corrosion rates at different temperature using MATLAB neural network toolbox. The FE results are in excellent agreement with an FFNN results, thus validating the accuracy and reliability of the proposed technique and leads to better understanding of the corrosion mechanism under different pipeline environmental temperature.

콘크리트내로 침투하는 염소이온 반응형 부식센서의 응답특성에 미치는 센서 세선 수의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete)

  • 이현석;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.143-152
    • /
    • 2014
  • 본 연구에서는 콘크리트내로 침투하는 염소이온을 모니터링하기 위하여, 스크린프리트 기법으로 염소이온 반응형 부식센서를 개발하고, 센서의 세선 수가 부식반응도 및 민감도에 미치는 영향을 실험을 통하여 정량적으로 분석하였다. 개발된 부식센서를 이용하여 염소이온량에 따라 부식 반응도을 확인하였으며, 센서의 파괴정도에 따른 저항변화에서는 단선형 센서보다 다선형 센서에서 큰 저항 변화를 나타내었다. 또한, 부식센서는 NaCl 수용액의 농도가 높은 만큼 센서의 저항변화가 크고, 콘크리트 내에서 센서 종류에 따른 부식저항은 단선형보다 다선형에서 민감도가 높게 나타났으며, 센서의 매설깊이가 클수록 저항변화 사이클 (cycle)은 증가하였다. 이상의 결과로, 본 연구에서 개발된 부식센서는 염분에 대한 부식반응과 민감도, 저항의 변화를 감지할 수 있었으며, 특히 7세선이 우수한 결과를 나타내어, 염분의 침투정도를 모니터링 하는데 가장 적합하다고 판단된다.

철근콘크리트에 매립된 철근의 부식 모니터링에 관한 실험적 연구 (An Experimental Study on the Monitoring of Corrosion of Rebar Embedded in Reinforced Concrete)

  • 박장현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.262-263
    • /
    • 2019
  • In this study, a sensor for detecting corrosion of rebar embedded in reinforced concrete structures was fabricated and its performance was verified. In order to monitor the open circuit potential(OCP) of the rebar embedded in reinforced concrete, a concrete embedded solid electrode was constructed as a sensor using MnO2. The OCP of the rebar could be observed using a sensor and a data logger. The decrease of the OCP to -510mV (vs.MnO2) or less was judged to be corrosion of the rebar. Since it is a solid-mediated sensor, it is more stable and durable than an electrode using an aqueous solution, and it is considered that the corrosion state of the rebar can be monitored for a long period of time.

  • PDF

콘크리트내 비래 염소이온 침투 모니터링을 위한 부식센서의 응답성능 평가에 관한 연구 (The study on Response of the Sensor for monitoring of Chloride Penetration in Concrete)

  • 신상헌;이현석;류화성;김보석;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.172-173
    • /
    • 2014
  • The study is used to verify the applicability of the sensor to monitor penetration of chloride into the concrete, like real coastal environment. After manufacturing the specimen adapt corrosion sensor for chloride penetration monitoring, chloride spray experiment was conducted. And then, It was checked the possibility of monitoring of the penetrated chloride by measuring the resistance of the corrosion sensor that was embedded in each depth of the concrete. Experimental results, it is confirmed that the corrosion resistance of the sensor was increased depending on the concentration of chloride. Therefore, it is estimated that the sensor is available for monitoring of chloride penetration.

  • PDF