• Title/Summary/Keyword: Sensor Calibration

Search Result 737, Processing Time 0.032 seconds

Preprocessing and Calibration of Optical Diffuse Reflectance Signal for Estimation of Soil Physical and Chemical Properties in the Central USA (미국 중부 토양의 이화학적 특성 추정을 위한 광 확산 반사 신호 전처리 및 캘리브레이션)

  • La, Woo-Jung;Sudduth, Kenneth A.;Chung, Sun-Ok;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.430-437
    • /
    • 2008
  • Optical diffuse reflectance sensing in visible and near-infrared wavelength ranges is one approach to rapidly quantify soil properties for site-specific management. The objectives of this study were to investigate effects of preprocessing of reflectance data and determine the accuracy of the reflectance approach for estimating physical and chemical properties of selected Missouri and Illinois, USA surface soils encompassing a wide range of soil types and textures. Diffuse reflectance spectra of air-dried, sieved samples were obtained in the laboratory. Calibrations relating spectra to soil properties determined by standard methods were developed using partial least squares (PLS) regression. The best data preprocessing, consisting of absorbance transformation and mean centering, reduced estimation errors by up to 20% compared to raw reflectance data. Good estimates ($R^2=0.83$ to 0.92) were obtained using spectral data for soil texture fractions, organic matter, and CEC. Estimates of pH, P, and K were not good ($R^2$ < 0.7), and other approaches to estimating these soil chemical properties should be investigated. Overall, the ability of diffuse reflectance spectroscopy to accurately estimate multiple soil properties across a wide range of soils makes it a good candidate technology for providing at least a portion of the data needed in site-specific management of agriculture.

Stereoscopic Video Compositing with a DSLR and Depth Information by Kinect (키넥트 깊이 정보와 DSLR을 이용한 스테레오스코픽 비디오 합성)

  • Kwon, Soon-Chul;Kang, Won-Young;Jeong, Yeong-Hu;Lee, Seung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.10
    • /
    • pp.920-927
    • /
    • 2013
  • Chroma key technique which composes images by separating an object from its background in specific color has restrictions on color and space. Especially, unlike general chroma key technique, image composition for stereo 3D display requires natural image composition method in 3D space. The thesis attempted to compose images in 3D space using depth keying method which uses high resolution depth information. High resolution depth map was obtained through camera calibration between the DSLR and Kinect sensor. 3D mesh model was created by the high resolution depth information and mapped with RGB color value. Object was converted into point cloud type in 3D space after separating it from its background according to depth information. The image in which 3D virtual background and object are composed obtained and played stereo 3D images using a virtual camera.

Real-Time Force Sensing in the Envelope of Zebrafish Egg during Micropipette Penetration

  • Yun, Seok;Kim, Deok-Ho;Kim, Byung-Kyu;Lee, Sang-Ho;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2451-2456
    • /
    • 2003
  • In biological cell manipulation, manual thrust or penetration of an injection pipette into an egg is currently performed by a skilled operator, relying only on visual feedback information. Massive load of various micro injection of either genes, fluid or cells in the postgenomic era calls a more reliable and automatic micro injection system that can test hundreds of genes or cell types at a single experiment. We initiated to study cellular force sensing in zebrafish eggs as the first step for the development of a more controllable micro injection system by any inexperienced operator. Zebrafish eggs at different developmental stages were collected and an integrated biomanipulation system was employed to measure cellular force during penetrating the egg envelope, the chorion. First of all, the biomanipulation system integrated with cellular force sensing instrument is implemented to measure the penetration force of cell membranes and characterize mechanical properties of zebrafish embryo cells. Furthermore, implementation of cellular force sensing system and calibration are presented. Finally, the cellular force sensing of penetrating cell membranes at each developmental stages was experimentally performed. The results demonstrated that the biomanipulation system with force sensing capability can measure cellular force at real-time while the injection operation is undergoing. The magnitude of the measured force was in the range of several hundreds of uN. The precise real-time measurement should provide the first step forwards for the development of an automatic and reliable injection system of various materials into biological cells.

  • PDF

Comparative study of the radiopacity of resin cements used in aesthetic dentistry

  • Montes-Fariza, Raquel;Monterde-Hernandez, Manuel;Cabanillas-Casabella, Cristina;Pallares-Sabater, Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the radiopacity of 6 modern resin cements with that of human enamel and dentine using the Digora digital radiography system, to verify whether they meet the requirements of ANSI/ADA specification no. 27/1993 and the ISO 4049/2000 standard and assess whether their radiopacity is influenced by the thickness of the cement employed. MATERIALS AND METHODS. Three 3-thickness samples (0.5, 1 and 1.5 mm) were fabricated for each material. The individual cement samples were radiographed on the CCD sensor next to the aluminium wedge and the tooth samples. Five radiographs were made of each sample and therefore five readings of radiographic density were taken for each thickness of the materials. The radiopacity was measured in pixels using Digora 2.6 software. The calibration curve obtained from the mean values of each step of the wedge made it possible to obtain the equivalent in mm of aluminium for each mm of the luting material. RESULTS. With the exception of Variolink Veneer Medium Value 0, all the cements studied were more radiopaque than enamel and dentin (P<.05) and complied with the ISO and ANSI/ADA requirements (P<.001). The radiopacity of all the cements examined depended on their thickness: the thicker the material, the greater its radiopacity. CONCLUSION. All materials except Variolink Veneer Medium Value 0 yielded radiopacity values that complied with the recommendations of the ISO and ANSI/ADA. Variolink Veneer Medium Value 0 showed less radiopacity than enamel and dentin.

Moon Imaging for the Calibration of the COMS Meteorological Imager (천리안 위성의 기상탑재체 보정을 위한 달 영상 획득 방안)

  • Park, Bong-Kyu;Yang, Koon-Ho
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.44-50
    • /
    • 2010
  • COMS accommodates multiple payloads; Meteorological Image(MI), Ocean Color Imager(GOCI) and Ka-band communication payloads. In order to improve the quality of MI visible channel, the moon image has been taken into account as backup reference in addition to Albedo monitoring. However, obtaining the moon image by adding special mission schedule is not recommended after IOT, because we may miss chances to obtain meteorological images during the time slots for special imaging. As an alternative solution, an approach extracting moon image from MI FD(Full Disk) image has been proposed when the moon is positioned near to the earth. However, prediction of acquisition time of moon image is somewhat difficult as the moon moves while the MI is scanning type sensor. And the moon can not be seen when it is behind the earth or outside of FD field of view. This paper discusses how effectively the moon can be detected by the MI FD imaging. For that purpose, this paper describes an approach taken to predict the time when the moon image is achievable and then introduces the results obtained from computer simulation.

다채널 표면 플라즈몬 공명 영상장치를 이용한 자기조립 단분자막의 표면 분석

  • Pyo, Hyeon-Bong;Sin, Yong-Beom;Yun, Hyeon-Cheol
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.74-78
    • /
    • 2003
  • Multi-channel images of 11-MUA and 11-MUOH self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. Patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each points on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in sub-nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching which are common in the detection methods based on the fluorescence.

  • PDF

Implementation on the Portable Blood Gas Analyzer and Performance Estimation (휴대형 혈액가스분석 시스템의 구현 및 성능평가)

  • Jeong, Do-Un;Jeon, Gye-Rok;Bae, Jin-Woo;Kim, Gil-Jung;Sim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.34-43
    • /
    • 2003
  • In this study, we implemented the measurement of pH, $pO_2$, $pCO_2$ of the arterial blood on a portable blood gas analysis system. This system is consist of two parts of hardware and software. The hardware part is divided into a fluidic mechanism and an electronic circuit unit. The system program is composed of operating, washing, correcting, and measuring routines. Both of 1-point and 2-point calibration schemes were used to enhance the accuracy of the measurement. In order to evaluate the performance of the developed system, we measured and performed statistical analysis on the characteristics of the sensing electrode response. As a result, coefficient variation was within 1.12, and maximum error was within 1.298%. We confirmed development possibility of portable blood gas analyzer.

Characteristics of conductive rubber belt on the abdomen to monitor respiration (호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성)

  • Kim, Kyung-Ah;Kim, Sung-Sik;Cho, Dong-Wook;Lee, Seung-Jik;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.24-32
    • /
    • 2007
  • Conductive rubber material was molded in a belt shape to measure respiration. Its resistivity was approximately $0.03{\;}{\Omega}m$ and the resistance-displacement relationship showed a negative exponent. The temperature coefficient was approximately $0.006{\;}k{\Omega}/^{\circ}C$ negligible when practically applied on the abdomen. The conductive rubber belt was applied on a normal male's abdomen with the dimensional change measured during resting breathing. The abdominal signal was differentiated ($F_{m}$) and compared with the accurate standard air flow rate signal ($F_{s}$) obtained by pneumotachometry. $F_{m}$ and $F_{s}$ differed in waveform, but the start and end timings of each breaths were clearly synchronized, demonstrating that the respiratory frequency could be accurately estimated before further processing of $F_{m}$. $F_{m}-F_{s}$ loop showed a nonlinear hysteresis within each breath period, thus 6 piecewise linear approximation was performed, leading to a mean relative error of 14 %. This error level was relatively large for clinical application, though customized calibration seemed feasible for monitoring general variation of ventilation. The present technique would be of convenient and practical application as a new wearable respiratory transducer.

Nitrogen Wash-Out Technique to Measure Functional Residual Capacity Based on Expired o2/Co2 Analysis (o2/Co2 분석기를 사용하여 폐의 기능적 잔기용량을 계측하는 질소세척법 개발)

  • Kim, Goon-Jin;Kim, Kyung-Ah;Lee, Jae-Hun;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • Functional residual capacity (FRC) is an important diagnostic parameter measured using $N_{2}$ analyzer. Since $N_{2}$ analyzer is expensive as well as cumbersome for use of noisy vacuum pump, the FRC measurement becomes possible only in large well-equipped hospitals. The present study introduced a new $TN_{2}$ wash-out technique to measure FRC by $O_{2}/CO_{2}$ analysis, which is relatively cheaper and much simpler to apply. Slower $O_{2}$ response was compensated for high frequency to be coincided with $CO_{2}$ response, thereby enabled indirect, but accurate $N_{2}$ concentration measurement. FRC was estimated by continuous integration of expired $N_{2}$ volume obtained with air flow signal. Experiment with 3 L syringe, a standard calibration device recommended by the American Thoracic Society, demonstrated less than 1% error at 0, 1, and 2 L. Correlation coefficient was almost ideal, guaranteeing linear estimation of FRC. The present technique is inexpensive and simple to apply, thus should he of great convenience.

Analysis of Saturation and Ground Water Level at Embankment by TDR Sensor (TDR센서를 이용한 제방의 포화도 및 지하수위 해석)

  • Kim, Ki-Young;Han, Heui-Soo;Lee, Jae-Ho;Park, Min-Cheol
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • The measured ground water behavior by TDR (time domain reflectometer) sensors were analyzed by the data filtering technique such as moving average method and Fourier transform, and the ground water level and unsaturated zone were tried to be determined numerically. At first, the variation of TDR data according to the saturation degree was measured by lab test, which is translated as a function of saturation degree. Then, changes of ground water level and lateral seepage in field conditions were simulated using acrylic pipe, and the measured data were analyzed to make calibration curve. Furthermore, TDR sensors were installed into the in-situ embankment to insure the field application. The saturation degree, unsaturated and dried zones were determined from the measured data.