• Title/Summary/Keyword: Sensor Assessment

Search Result 388, Processing Time 0.026 seconds

Nano-delamination monitoring of BFRP nano-pipes of electrical potential change with ANNs

  • Altabey, Wael A.;Noori, Mohammad;Alarjani, Ali;Zhao, Ying
    • Advances in nano research
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • In this work, the electrical potential (EP) technique with an artificial neural networks (ANNs) for monitoring of nanostructures are used for the first time. This study employs an expert system to identify size and localize hidden nano-delamination (N.Del) inside layers of nano-pipe (N.P) manufactured from Basalt Fiber Reinforced Polymer (BFRP) laminate composite by using low-cost monitoring method of electrical potential (EP) technique with an artificial neural networks (ANNs), which are combined to decrease detection effort to discern N.Del location/size inside the N.P layers, with high accuracy, simple and low-cost. The dielectric properties of the N.P material are measured before and after N.Del introduced using arrays of electrical contacts and the variation in capacitance values, capacitance change and node potential distribution are analyzed. Using these changes in electrical potential due to N.Del, a finite element (FE) simulation model for N.Del location/size detection is generated by ANSYS and MATLAB, which are combined to simulate sensor characteristic, therefore, FE analyses are employed to make sets of data for the learning of the ANNs. The method is applied for the N.Del monitoring, to minimize the number of FE analysis in order to keep the cost and save the time of the assessment to a minimum. The FE results are in excellent agreement with an ANN and the experimental results available in the literature, thus validating the accuracy and reliability of the proposed technique.

A study on indoor navigation system using localization based on wireless communication (무선통신기반 위치인식을 이용한 실내 내비게이션 시스템에 관한 연구)

  • Kim, Jung-Ha;Lee, Sung-Geun;Kim, Jong-Su;Kim, Jeong-Woo;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.114-120
    • /
    • 2013
  • Recently, navigation systems based on wireless communication have been applied to the internal structures such as building or ship. If a stable azimuth information is obtained, these systems can effectively guide the direction of the user's progress through the information and then can improve the performance of guidance. Since conventional method which has acquired an azimuth information using geomagnetic and acceleration sensor(azimuth sensor hereafter) is sensitive to the effects of the magnetic field, it has unstable error range according to the surrounding environment. In order to improve these problems, this paper presents a new relative azimuth estimation algorithm using the displacement of a mobile node and its rotation angle based on Wireless communication. For the performance assessment of the proposed algorithm, experiments using rotating arm are performed and the results are confirmed that the proposed system can estimate the relative azimuth without using additional sensors.

Development of a Low Frequency Accelerometer using the Fiber Bragg Grating Sensor (Fiber Bragg Grating 센서를 이용한 저진동 가속도계 개발)

  • Pack, In-Seok;Kang, Han-Bin;Lee, Kye-Kwang;Lee, Seok-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1101-1109
    • /
    • 2012
  • Accelerometers play a key role in the structural assessment. However, the current electric type accelerometers have certain limitations to apply some structures such as heavy cabling labor, installed sea structure and sensitivity to electromagnetic fields. An optical Fiber Bragg Grating (FBG) accelerometer has many advantages over conventional electrical sensors since their immunity to electromagnetic interference and their capability to transmit signals over long distance without any additional amplifiers, and there is no corrosion from sea water. In this paper, we have developed a new FBG-based accelerometer. The accelerometer consists of two cantilevered type beams and a mass and two rollers. A bragg grating element is not directly glued to a cantilever to avoid possible non-uniform strain in the element. Instead, the bragg grating element will be attached to rotation part that rolled inducing vertical movement of the mass and support cantilever beams so that the bragg grating element is uniformly tensioned to achieve a constant strain distribution. After manufacturing, we will prove the performance and the natural frequency of the accelerometer through the experiment with a vibration shaker. The FBG-based accelerometer is developed for measuring the vibration not exceeding 50 Hz for the marine and civil structures.

An Optical Technique for Concentration Measurement by Color Analysis (반사형 소자를 이용한 시료의 컬러정보 및 농도분석)

  • Lee, Tae-Hee;Kim, Ji-Sun;Jung, Gu-In;Choi, Ju-Hyeon;Oh, Han-Byeol;Kim, A-Hee;Jung, Hyon-Chel;Cho, Yeong Bin;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1121-1127
    • /
    • 2014
  • Many studies have been done to measure and analyze color for various purposes. Visual assessment has lack of objectivity and the equipment for color measurement is very expensive. In this study, we developed a device for quantitative analysis of the color using optical elements. With the color sensor, the ratio of RGB was calculated by measuring the light intensity that is reflected from an object. Inverse transformation of optical signal was performed to detect the color density. The suggested color analyzer can detect color information as well as sample concentration. Results of this study are expected to be used in various medical fields such as pH indicator and urine analysis.

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

Utilization of a Microphone to Acquire Mobility in Seismic Testing (탄성파시험의 이동성 확보를 위한 마이크로폰 센서의 활용)

  • Joh, Sung-Ho;Ramli, Bukhari;Rahman, Norinah Abd
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1509-1521
    • /
    • 2013
  • Social demand for the stability of structures lead to the development of the technology to accomplish it. The non-destructive seismic technique, which is able to assess structural integrity of infrastructures, belongs to this category. Seismic technique is focused on the measurement of seismic velocity propagating through the material, and has to utilize sensors coupled to material surface, which does not allow the testing to be performed on the fly. In this paper, a general vocal microphone, which works as a non-contact sensor, was adopted to facilitate seismic testing with mobility and efficiency improved. The target of using microphones was oriented toward quality assessment of compacted subgrade, stiffness evaluation and health monitoring of concrete structures. Experimental parametric study and field applications were performed to investigate reliability and efficiency of microphones. Finally, the optimal test configuration of microphones was suggested for resonance tests and surface-wave tests.

Design of Digital Inclinometer for Measuring Postural Balance (자세 균형 측정을 위한 디지털 경사계 설계)

  • Myoung, Hyoun-Seok;Lee, Hyo-Ki;Kwon, Oh-Yun;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.1
    • /
    • pp.50-56
    • /
    • 2008
  • In this paper, a digital inclinometer to measure the angle and acceleration signals of subject laid on Roll was designed. The designed system consists of a tilt sensor, biaxial accelerometer, single chip microprocessor and Bluetooth module. The designed digital inclinometer was easy to handle and to wear. To evaluate the performance of the system, we measured simultaneously the angle and acceleration signals from the 3 subjects on the Roll using two instruments which are ZEBRIS and designed system. The measured signals were processed by statistical method and then the correlation coefficient of 0.93 was shown. From the results, the designed digital inclinometer is shown to be useful in assessment of body movement.

Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG (심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.104-109
    • /
    • 2018
  • A non-intrusive ECG and BCG measurement system is introduced. The system is built on a auxiliary backrest of a chair. The developed system is aimed to non-intrusive assessment of cardiovascular dynamic indices such as pulse arrival time(PAT) and pre-ejection period (PEP). In the system, capacitive active electrodes and capacitive grounding were used for the non-intrusive indirect-contact ECG measurement, and EMFi pressure sensor was used for the non-intrusive BCG measurement. The capacitive active electrodes and the EMFi sensor were attached on the backrest. Using the system, ECG and BCG were successfully acquired. The measured BCG showed peaks that following ECG R peaks. It was shown that the time interval between Q wave in ECG and first peak in BCG correlates Pre-ejection period measured by impedance-cardiogram. The results showed that the introduced system can be used for the non-intrusive various cardiovascular information including ECG, PAT, PEP.

Implementation of an Artificial Odour Recognition System with Unsupervised Clustering Methods (Unsupervised clustering 방법을 갖는 인공 냄새인식 시스템의 구현)

  • Choi, Chan-Seok;Kim, Jeong-Do;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.310-316
    • /
    • 2001
  • We have been designed and constructed an artificial odour recognition system(electronic nose system) using metal oxide type sensor array for recognizing and analyzing various odours. We proposed an unsupervised clustering method based on Euclidean distances in order for human observer to examine easily multi-dimensional data, which has been measured from an array of sensors. This is a combination of Principal Components Analysis(PCA) used as a starting point for Sammom Mapping Method(SMM). No prior assumptions are made of the classes in which odour belong, and the error due to dimensional reduction at the PCA can be minimized without the disadvantages of rotation of clusters when the order of data sets in a data base was changed in the SMM. An artificial odour recognition system with the proposed unsupervised clustering method was applied to assessment of odour differences of Volatile Organic Compounds(VOCs) and Korean whiskies respectively, and demonstrated the best performances throughout the experimental trails.

  • PDF

Research trends on prevention of heat stroke using clothing: Focusing on practical research in Japan (의복을 활용한 열중증 예방 대책에 관한 연구 동향 조사: 일본의 실용 지향적 연구를 중심으로)

  • Son, Su-Young
    • Human Ecology Research
    • /
    • v.56 no.5
    • /
    • pp.473-491
    • /
    • 2018
  • This study identifies Japanese study content on heat stroke prevention measures using clothes, provides basic data for quantitative wearing assessment studies, presents a developmental direction for those, and helps invigorate further research. Studies were collected concerning clothing-based heat stroke measures in order to analyze the following factors: current status of heat stroke by industry and working environment, heat stroke and body cooling method, clothing microclimate and air circulation in a hot environment, hot environments and wearable sensors, and heat stress reduction and skin exposure. The current WBGT standard does not consider the diversity of wearing clothes according to the working environment. Therefore, it is preferable to add a correction value in consideration of design, materials, and ventilation to prevent heat strokes. For the heat stroke and body cooling method, wearing water-perfused clothing is effective to reduce heat stress and maintain exercise ability. Changing the material and design of clothing or wearing air-conditioned clothing can improve ventilation and the clothing microclimate. However, further evaluation is needed on the effectiveness of air-conditioned clothing as a heat stroke prevention product. The measurement method using a wearable sensor can provide real-time data on the body response due to working in a hot environment. Therefore, it is an effective alarm for heat stroke. Skin exposure area and heat dissipation efficiency should be considered to prevent heat stroke. Reducing the covering area by exposing the head, neck, and limbs, and wearing breathable material can prevent heat stroke from increased body temperature.