• Title/Summary/Keyword: Sensitivity tester

Search Result 26, Processing Time 0.018 seconds

A Study on the Development of High-sensitivity AEC-sensor for Minimization of Dose Creep in Diagnostic Imaging System (진단영상 시스템에서 선량크리프 현상의 최소화를 위한 고감도 AEC 센서에 관한 연구)

  • Kim, Kyo-Tae;Han, Moo-Jae;Heo, Ye-Ji;Kim, Joo-Hee;Kang, Sang-Sik;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.321-325
    • /
    • 2016
  • Dose creep is one of clinical errors that arises from the tester's inexperience or carelessness, and according to Task Group #116 of American Association of Physicists in Medicine, its continued occurrence is being reported in the digital method. At this point, the demand for an automatic exposure control device that minimizes the dose creep phenomenon and can improve reproducibility is increasing. In this study is to consider the automatic exposure control device sensor that can is not only easy to produce, but also reduce the dose creep phenomenon by conducting a research on high-efficient semiconductor sensor. As a result, the Intrinsic-type and PIN-type sensors have excellent optical property compared to Ref sensor, would have less shading effect, and have relatively low sensitivity, but would provide accurate feedback signals to automatic exposure control device with its consistent tendency according to exposure condition changes.

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Desensitizing Effects of a Nd:YAG Laser Irradiation on Hypersensitive Dentine (지각과민치아에 대한 Nd:YAG 레이저 조사의 효과)

  • Jung, Sung-Yong;Kim, Kyoung-Hee;Ko, Myong-Yun;Ahn, Yong-Woo;Park, Jun-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.465-473
    • /
    • 2005
  • The purpose of this study was to evaluate the desensitizing effects of a Nd:YAG laser (Sunlase, SUNRISE Technologies, Inc., USA) irradiation on cervically exposed hypersensitive dentine. 45 patients was irradiated with pulsed Nd:YAG laser (1.5 W, 20 Hz, 75 mJ/pulse, 4 minutes) as the experimental group, 27 patients was mock irradiated as the control group. The degree of sensitivity to the thermal and tactile stimuli were determined qualitatively with an evaporative stimulus defined as two times air blast at a distance of 3 mm from each site to be tested and with a mechanical stimulus as a slightly scratching the cervical site with a dental explorer. A qualitative registration of the degree of discomfort was determined according to a numerical pain scale(NPS) in an 11-point scale in which 0= "no pain" and 10="most excruciating pain imaginable". Recordings were assessed before treatment, immediately after, 1 and 2 weeks after treatment. Pain tolerance threshold and pulp vitality were evaluated with electric pulp tester before and immediately after treatment. 1. Desensitizing of hypersensitive dentine with Nd:YAG laser irradiation was more effective than that with mock irradiation. 2. The placebo effect of mock irradiation was recognized for severe sensitive teeth($NPS\;{\geqq}\;6$), but not for moderate sensitive teeth(NPS < 6). 3. Laser irradiation did not affect the pain tolerance threshold and pulp vitality of the hypersensitive teeth. 4. Desensitizing effect of laser irradiation for the hypersensitive teeth had been continuing at least 2 weeks. It was concluded that desensitizing of hypersensitive dentine with a Nd:YAG laser is effective and the maintenance of the positive result was more prolonged than the placebo effect.

Effects of GaAs (904 nm) Low Level Laser Therapy on Dentin Hypersensitivity (과민치아에 대한 904nm GaAs 반도체레이저의 효과)

  • Won, Tae-Hee;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.4
    • /
    • pp.215-224
    • /
    • 2011
  • The aim of the study was to investigate the effects of 904 nm GaAs laser irradiation for patients with hypersensitive teeth and to find the possibility of clinical use of this Low Level Laser Therapy (LLLT) for the control of hypersensitive teeth. Eleven patients visited Dept. of Oral Medicine, Dankook University participated in this study. Each patient contributed at least two or more contralateral pairs of hypersensitive teeth with exposed dentine at cervical surfaces. Total number of teeth used from subjects participated in this study was 50: 25 experimental and control teeth respectively. All participants were treated with 904 nm GaAs diode laser every week during 4 weeks. Tactile and cold (ice stick) tests were carried out before LLLT every week during 4 weeks and 1 week later after the last LLLT by measuring visual analogue scale (VAS) of patients and by measuring a score of electrical pulp tester (EPT) simultaneously. The VAS score in tactile test decreased significantly with time, but there was not statistically difference between those of groups. The score of EPT in the experimental group was significantly higher than that of control group, although there was no change with time. In cold test, there was significant difference between two groups and cold sensitivity of the experimental group significantly decreased with time after every LLL irradiation, compared with that of control group. Based on the results, it is suggested that the 904 nm GaAs laser irradiation could be positively used as an effective, reversible method in treating cervical dentine hypersensitivity.

Basic Research on Potential Application of Fire Detection by Measuring Fire Detection Tendency of Indoor Air Quality Measurement Factors (실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구)

  • Choi, Su-Gil;Young, Jin-Se;Park, Sang-Min;Nam, Yeong-Jae;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.37-46
    • /
    • 2020
  • This is a basic research on potential application of fire detection by measuring fire detection tendency of indoor air quality measurement factors. In this study, operation experiment using smoke detector sensitivity tester and paper fire experiment specified in UL 268 standards were conducted to evaluate the fire detection tendency of indoor air quality measurement factors. Based on the cross-substitution of values measured in the paper fire experiment, PM10 (excluding average) and HCHO (excluding average and maximum) for the indoor air quality meter (IAQ); PM1.0, PM2.5, and PM10 for IAQ S2; and CO (excluding the average and maximum) for combustion gas analyzers showed consistent tendency despite changes in the measured values for smoke generation under all experimental conditions. In particular, PM10 and CO are considered the most applicable fire detection factors among the factors measured in the experiment.

BI-AXIAL FRACTURE STRENGTH OF RESIN MODIFIED GLASS IONOMERS (레진강화형 글라스아이오노머의 2 축 굽힘강도)

  • Lee, Yong-Keun;Im, Mi-Kyung;Koo, Dae-Hoi;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.751-760
    • /
    • 1997
  • Resin-modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strengths of the conventional glass ionomers, and to maintain their dinical advantages. The purpose of this study was to evaluate the bi-axial fracture strength of four resinmodified glass-ionomers(Fuji II LC, Vitremer, Dyract, VariGlass), one resin composite material(Z-100), and one conventional glass-ionomer(Fuji II). Three specimens of each material and shade combination were made according to the manufacturers' instructions. Materials were condensed into metal mold with a diameter of 10mm and a thickness of 2.0mm and pressed between two glass plates. Resin-modified glass ionomers were polymerized using a Visilux II light curing unit by irradiating for 60 seconds from both sides, and conventional glass ionomer was cured chemically. After specimens were removed from the molds, surfaces were polished sequentially on wet sandpapers up to No. 600 silicone carbide paper. The specimens were thermocycled for 2,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ distilled water. After thermocycling, bi-axial fracture strengths were measured using a compressive-tensile tester(Zwick 1456 Z020, Germany) with the cross head speed of 0.5mm/minute. The results were as follows: 1. Two factors of the kind and color of materials had a main effect on bi-axial fracture strength (p<0.01), and bi-axial fracture strength was influenced significantly by the kinds of materials (p<0.01). But there was no significant interaction between two variables of the kind and color of materials (p>0.05). 2. Comparing the mechanical properties of the materials, the elastic modulus of Z100 was higher than any other material, and there was no difference in the displacement at fracture among materials. The bi-axial fracture strength of Z100 was significantly higher than any other material, and that of resin-modified glass ionomers was significantly higher than that of conventional glass ionomer (p<0.05). 3. In the same material group, the color of material had little influence on the mechanical properties.

  • PDF