• Title/Summary/Keyword: Sensitivity coefficient

Search Result 924, Processing Time 0.029 seconds

A SENSITIVITY STUDY ON NEUTRONIC PROPERTIES OF DUPIC FUEL

  • Park, Hangbok;Roh, Gyu-Hog
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.124-129
    • /
    • 1998
  • A sensitivity study has been done to determine the composition of DUPIC fuel from the viewpoint of neutronics fuel design. The spent PWR fuel compositions were generated and fissile contents adjusted by blending fresh uranium after mixing two spent PWR fuel assemblies. The $^{239}$ Pu and $^{235}$ U enrichments of DUPIC fuel were adjusted by controlling the amount of fresh uranium feed and the ratio of slightly enriched and depleted uranium in the fled uranium. Based on the material balance calculation, it is recommended that DUPIC fuel composition be such that spent PWR fuel utilization is more than 90%.. A sensitivity study on the temperature reactivity coefficient of DUPIC fuel has shown that it is desirable to increase the $^{239}$ Pu and $^{235}$ U contents to reduce both the fuel and coolant temperature coefficients. On the other hand, refueling simulations of the DUPIC core have shown that the channel power peaking factor, which is a measure of the reactor trip margin, increases with the total fissile content. Considering these neutronic characteristics of the DUPIC fuel, il is recommended to have enrichments of 0.45 and 1.00 wt% for $^{239}$ Pu and $^{235}$ U, respectively.

  • PDF

Life Cycle Cost & Reliability Analysis of Quaywall Design Parameters (안벽 설계변수의 신뢰성 해석과 생애주기비용 분석)

  • Kim, Hong-Yeon;Yoon, Gil-Lim;Yoon, Yeo-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.508-518
    • /
    • 2008
  • Reliability and sensitivity analysis of the design parameters for a section of caisson type quaywall which is the most applicable in Korea were performed. It was tried to estimate probabilities of failure for the system of the multiple failure modes and to analyze LCC in the quaywall structure. The reliability analysis was performed by FORM. Also, sensitivity indices were estimated using the reliability indices, which may be used inferring effects of each design parameter on the reliability indices. As a result, the coefficient of friction between caisson and rubble, the moment by self weight and the moment of resistance mostly affected on the reliability indices in the sliding, overturning and foundation failure, respectively. System reliability theorem was applied in order to estimate the probabilities of failure for the system of the multiple failure modes. As the results of estimation of the probabilities of failure for the system, all cases were more conservative than those for the elements, according to both failure mode and load combination applied to series system. It entirely exceeded the target reliability index, but it was consistent with the theorem. According to the optimum LCC with the width of the caisson, the probability of failure exceeded the target probability of failure at then time. Therefore, it was judged to be insufficient to the practical application.

  • PDF

Diagnostic value of eosinopenia and neutrophil to lymphocyte ratio on early onset neonatal sepsis

  • Wilar, Rocky
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.6
    • /
    • pp.217-223
    • /
    • 2019
  • Purpose: To determine the diagnostic value of eosinopenia and the neutrophil-to-lymphocyte ratio (NLR) in the diagnosis of early onset neonatal sepsis (EONS). Methods: This cross-sectional study was conducted in the Neonatology Ward of R.D. Kandou General Hospital Manado between July and October 2017. Samples were obtained from all neonates meeting the inclusion criteria for EONS. Data were encoded using logistic regression analysis, the point-biserial correlation coefficient, chi-square test, and receiver operating characteristic curve analysis, with a P value <0.05 considered significant. Results: Of 120 neonates who met the inclusion criteria, 73 (60.8%) were males and 47 (39.2%) were females. Ninety (75%) were included in the sepsis group and 30 (25%) in the nonsepsis group. The mean eosinophil count in EONS and non-EONS groups was $169.8{\pm}197.1cells/mm^3$ and $405.7{\pm}288.9cells/mm^3$, respectively, with statistically significant difference (P<0.001). The diagnostic value of eosinopenia in the EONS group (cutoff point: $140cells/mm^3$) showed 60.0% sensitivity and 90.0% specificity. The mean NLR in EONS and non-EONS groups was $2.82{\pm}2.29$ and $0.82{\pm}0.32$, respectively, with statistically significant difference (P<0.001). The diagnostic value of NLR in the EONS group (cutoff point, 1.24) showed 83.3% sensitivity and 93.3% specificity. Conclusion: Eosinopenia has high specificity as a diagnostic marker for EONS and an increased NLR has high sensitivity and specificity as a diagnostic marker for EONS.

The Influence of Human Rights Sensitivity and the Nursing Work Environment on Workplace Bullying Victimization among Nurses in Small- and Medium-Sized Hospitals (중소병원 간호사의 인권감수성과 간호근무환경이 직장 내 괴롭힘 피해에 미치는 영향)

  • Cho, Eun-Kyung;Kim, Moon-Jeong
    • The Korean Journal of Health Service Management
    • /
    • v.13 no.3
    • /
    • pp.27-38
    • /
    • 2019
  • Objectives: The purpose of this study was to examine the influence of human rights sensitivity and nursing work environment on workplace bullying victimization among nurses in small- and medium-sized hospitals. Methods: The participants were 255 nurses from 5 general hospitals in Busan. A dataset was collected using a structured self-reporting questionnaire during the month of July 2018. The data were analyzed with SPSS WIN 23.0 software (IBM Corp., Armonk, NY, USA) using independent t-test, one-way analysis of variance, Pearson's correlation coefficient, and multiple regression analysis. Results: Nursing work environment showed negative correlation with workplace bullying victimization. Being a witness to bullying, organizational support, head nurse's leadership, and relationships with peers were found to influence workplace bullying victimization, and these 4 variables explained 37% of workplace bullying victimization. Conclusions: Formal procedures for cases of bullying and improvements in the leadership of head nurses and peer relationships are crucial to reducing workplace bullying victimization among nurses in small- and medium-sized hospitals. Hospital executives' efforts to provide sufficient physical and human resources for nursing services and to improve the welfare of nurses are also needed.

Influence of Ethical Sensitivity and Person-environment Fit on Person-centered Care of Nurses in Long-term Care Hospitals (요양병원 간호사의 윤리적민감성과 개인-환경적합성이 인간중심돌봄에 미치는 영향)

  • Lee, Hye Ran;Yang, Nam Young
    • Journal of Home Health Care Nursing
    • /
    • v.29 no.2
    • /
    • pp.175-182
    • /
    • 2022
  • Purpose: The study examined the effects of ethical sensitivity and person-environment fit on person-centered care of nurses in long-term care hospitals. Methods: The participants were 111 nurses. Data were analyzed using descriptive statistics, t-test, ANOVA, Pearson's correlation coefficient, and multiple regression analysis with the SPSS program. Results: The mean of person-centered care was 2.95±0.62 out of 5. There were significant differences in person-centered care in terms of age, shift pattern, total clinical career, and educational experience of person-centered care. Person-centered care and ethical sensitivity, person-centered care and person-environment fit showed a positive correlation. Factors affecting the person-centered care were the age (20-29), shift pattern (three shift), person-environment fit. The explanatory power was 42%. Conclusion: These results can be used to increase the person-environment fit and adopt a differented approach based on age and shift pattern in order to enhance person-centered care. Therefore, it is necessary to develop and apply an person-centered care program for nurses in long-term care hospitals.

Highly Sensitive Optical-fiber Humidity Sensor Based on Nafion-PVA Sol-gel

  • Ning, Wang;Yuhao, Li;Xiaolei, Yin;Wenting, Liu;Shiqi, Liu; Xuwei, Zhao; Yanxi, Zhong;Liang, Xu
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 2023
  • A highly sensitive optical-fiber humidity sensor is demonstrated in this paper. By using Nafion-PVA sol-gel and single-mode optical fibers, the Fabry-Perot humidity sensor is easily fabricated. In the humidity range of 29%-72%, humidity-response experiments are carried out with a cycle of rising and falling humidity to investigate humidity-response characteristics. The experimental results show 2.25 nm/%RH sensitivity and a 0.9997 linear correlation coefficient, with good consistency. The changes in optical-path difference (OPD) and free spectral range (FSR) with humidity are also discussed. The humidity sensitivities of a typical sensor are 80.3 nm/%RH (OPD) and 0.03 nm/%RH (FSR). Furthermore, many humidity sensors with different Nafion-PVA sol-gel concentration and initial cavity length are experimentally investigated for humidity response. The results show that the sensitivity increases with higher Nafion ratio of the Nafion-PVA sol-gel. The influence of changing cavity length on sensitivity is not obvious. These results are helpful to research on optical-fiber humidity sensors with good performance, easy fabrication, and low cost.

Photosensitive Effects of Poly(vinyl cinnamoyl acetate) by New Squarylium Dyes(II) (신규 Squarylium Dyes에 의한 Poly(vinyl cinnamoyl acetate)의 고감도화(II))

  • 손세모;곽선엽
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.1
    • /
    • pp.113-120
    • /
    • 2000
  • A previous paper was reported in being sensetized photopolymer, poly(vinyl cinnamoyl acetate) (PVCiA)1) with some squarylium dyes such as 1,3-bis(4 or 6-trifluouomethy1-1,3,3-trimethylindo) squarylium dyes(TFSQ). Here, we synthesized new 1,3-bis(4 or 6-nitro-1,3,3-trimethylindo) squarylium dyes(NISQ) to sensetize photopolymer, such as poly(vinyl cinnamoyl acetate). Absorption's coefficient of (NISQ8) is 8.5x105, the sensitivity of PVCiA added with NISQ8(3%) was highly sensitized 8 times than not added, and 2 times than TFSQ8(3%). Maybe, high absorption'scoefficient and red shift of NISQs with strongly withdrawing group to TFSQs afford to the high sensitivity of PVCiA.

  • PDF

Temperature Compensated Hall-Effect Power IC for Brushless Motor

  • Lee, Cheol-Woo;Jang, Kyung-Hee
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.74-77
    • /
    • 2002
  • In this paper we present a novel temperature compensated Hall effect power IC for accurate operation of wide temperature and high current drive of the motor coil. In order to compensate the temperature dependence of Hall sensitivity with negative temperature coefficient(TC), the differential amplifier has the gain consisted of epi-layer resistor with positive TC. The material of Hall device and epi-resistor is epi-layer with the same mobility. The variation of Hall sensitivity is -38% at 150$^{\circ}C$ and 88% at - 40$^{\circ}C$. But the operating point(B$\sub$op/) and release point(B$\sub$RP/) of the Hall power IC are within ${\pm}$25%. The experimental results show very stable and accurate performance over wide temperature range of -40$^{\circ}C$ to 125$^{\circ}C$.

  • PDF

Model Updating in Small Structural Dynamics Model by Elimination of Mass Loading Effect of Accelerometer (가속도계 영향을 제거한 소형 구조물의 동특성 모델 개선)

  • Lee, Jung Youn
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.40-47
    • /
    • 2015
  • Dynamic response of any small structure is always affected by the mass of the attached accelerometer. This paper predicts the natural frequencies and frequency response functions by removing the mass loading effect from the accelerometer. This mass loading is studied on a simple cantilever beams by varying the location of accelerometer. By using sensitivity analysis with iteration method, accelerometer mass and location are obtained. The predicted natural frequencies of the small cantilever beam without the accelerometer's mass show good agreement with the structural re-analysis.

Planar Vibratory Gyroscope using Electrostatic Actuation and Electromagnetic Detection (정전력 구동 및 전자력 검출형 평면 진송 각속도계)

  • 이상훈;임형택;이승기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1089-1092
    • /
    • 1995
  • A planar vibratory gyroscope using electrostatic actuation and electromagnetic detection is proposed. The gyroscope has large sensitivity and can be fabricated by using surface micrimachining, bulk micromachining and conventional machining technology. In this paper, the gyroscope and the electromagnetic detecting system equations are derived to determine the output characteristics for the planar vibratory gyroscope using electrostatic acturation and electromagnetic detection. The maximum output is obtained when the driving frequencyequals to the detecting frequency. The resonant frequencies of the resonator are determined by the beam stiffness, i.e. the material constants and spring dimensions. The dimensions of the beams are determined using the analytic vibration modelling. The expected resonant frequencies are 200Hz both and the sensitivity is 62mV/deg/sec with 4000 electronic circuit amplifying coefficient for an AC drive voltage of 3V bias voltage of 15V and DC field current of 50 mA.

  • PDF