• Title/Summary/Keyword: Sensitivity Measurement

Search Result 1,310, Processing Time 0.034 seconds

A Case Study for Pricing Strategy Planning of a Family Restaurant Using Price-Sensitivity Measurement (패밀리 레스토랑의 가격 전략 수립을 위한 가격민감성 분석 사례 연구)

  • Choi Mi-Kyung;Lee Bong-Shik
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.2
    • /
    • pp.253-260
    • /
    • 2006
  • The purpose of this study was to suggest menu pricing strategy based on understanding about customer perceived value of products and services. The technique known as PSM (Price Sensitivity Measurement) was used for analysis of price sensitivity for 3 menu items of a family restaurant in Seoul. A questionnaire was developed through literature review and modified after pilot test. Questionnaires for the main survey were distributed to 250 customers on their visit to the restaurant, and a total of 138 questionnaires were used for analysis (55.2%). The statistical analysis of price sensitivity was conducted using PSM, and descriptive analyses were conducted using SPSS Win (12.0). The main results of this study were as follows: the price sensitivity of beef tenderloin steak was higher than two other menus and the stress range of teriyaki chicken was almost 0, that is, the price sensitivity of teriyaki chicken was very low. Present menu prices of 3 menu items were within the range of acceptable prices, but had some distances from the optimal pricing point. From the result of this study, it was concluded that price adjustment or price promotion strategy would be effective for increase in sales of beef tenderloin steak, and marketing strategies to enhance consumers' perceptions of value should be conducted for all menu items by situations. Overall, PSM technique could be a helpful tool for researchers and managers of foodservice organizations to understand how consumers' perceptions of value are affected by the interaction of price and quality.

Estimation of baroreflex sensitivity using pulse arrival time rather than systolic blood pressure measurement

  • Lee, Jong-Shill;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Baroreflex sensitivity (BRS) is a parameter of the cardiovascular system that is reflected in changes in pulse interval (PD and systolic blood pressure (SBP). BRS contains information about how the autonomic nervous system regulates hemodynamic homeostasis. Normally the beat-to-beat SBP measurement and the pulse interval measured from the electrocardiogram (ECG) are required to estimate the BRS. We investigated the possibility of measuring BRS in the absence of a beat-to-beat SBP measurement device. Pulse arrival time (PAT), defined as the time between the R-peak of the ECG and a single characteristic point on the pulse wave recorded from any arterial location was measured by photoplethysmography. By comparing the BRS obtained from conventional measurements with our method during controlled breathing, we confirmed again that PAT and SBP are closely correlated, with a correlation coefficient of -0.82 to -0.95. The coherence between SBP and PI at a respiration frequency of 0.07-0.12 Hz was similar to the coherence between PAT and PI. Although the ranges and units of measurement are different (ms/mmHg vs. ms/ms) for BRS measured conventionally and by our method, the correlation is very strong. Following further investigation under various conditions, BRS can be reliably estimated without the inconvenient and expensive beat-to-beat SBP measurement.

Sensitivity Enhancement of Shadow Moiré Technique for Warpage Measurement of Electronic Packages (반도체 패키지의 굽힘변형 측정을 위한 그림자 무아레의 감도향상 기법연구)

  • Lee, Dong-Sun;Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.57-65
    • /
    • 2015
  • Electronic packages consist of various materials, and as temperature changes, warpage occurs because of the difference in coefficient of thermal expansion. Shadow $moir{\acute{e}}$ is non-contact, whole field measurement technique for out-of-plane displacement. However, the technique has low sensitivity above $50{\mu}m/fringe$, it is not adequate for the warpage measurement in some circumstance. In this paper, by applying phase shifting process to the traditional shadow $moir{\acute{e}}$, measurement system having enhanced sensitivity of $12.5{\mu}m/fringe$ is constructed. Considering Talbot effect, the measurement is carried out in the half Talbot area. Shadow fringe pattern having four times enhanced sensitivity is obtained by the image process with four shadow fringes. The measurement technique is applied to the fibered package substrate and coreless package substrate for measuring warpages at room temperature and at about $100^{\circ}C$.

A Study on Measurement Uncertainty of Insensitive Munitions Tests (둔감탄약 시험의 측정불확도 산출 방안 연구)

  • Kim, Min;Kim, Jong-Myoung;Yang, Seung-Ho;Sun, Tae-Boo
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.533-547
    • /
    • 2017
  • Purpose: This study proposes the main sources of uncertainty and uncertainty analysis of a measurement system of insensitive munitions tests. Methods: We established the mathematical model for calculating measurement uncertainty of insensitive munitions tests, conducted experiments for calculating uncertainties of dynamic sensitivity and overshoot value, and estimated the distributions of uncertainty factors. Results: The measurement uncertainty calculation methods are presented, which include experimental data processing methods for calculating uncertainties of dynamic sensitivity and overshoot value. Conclusion: The measurement of explosion pressure in insensitive munitions tests is an important issue to the reporting test results and classifying reaction types. The more efforts to ensure the reliability of the insensitive munitions tests results are required.

A Study on the Measurement of Halitosis of Human Mouth with Chemical Gas Sensor Arrays (화학 가스센서를 활용한 구취측정 방법에 관한 연구)

  • Lee, Seok-Jun;Kim, Sun-Tae;Kim, Han-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.279-285
    • /
    • 2011
  • This study was carried out to apply chemical gas sensors for the identification of bad breath which is one of the important sensitive problem for the humans' daily life. Seven sensors, including five semiconductor sensors and two electrochemical sensors, were tested for the three panels three times in several conditions. The results showed that the reproducibility of sensors were generally good, and electrochemical sensors showed better reproducibility while semiconductor sensors showed better sensitivity. No rinsing before measurement showed relatively better results in terms of both sensitivity and reproducibility. Semiconductor gas sensors for hydrogen sulfide shows the highest sensitivity, and it was recommended to use the odor-free bag for the measurement of bad breath.

Developing Room Pricing Marketing Strategy of the National Recreation Forest Using Price-Sensitivity Measurement (가격민감성분석을 이용한 국립자연휴양림 객실가격 마케팅 전략 개발)

  • Han, Sang-Yoel;Kim, Jae-Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.118-126
    • /
    • 2008
  • This research was conducted to develop pricing strategy based on understanding about customer perceived value of lodging facilities in national recreation forest. The technique known as PSM (price-sensitivity measurement) was used for analysis of price sensitivity for two kinds of lodging (log-cabin and forest-hotel) and for room sizes (4, 5, 6, 7 persons). PSM questionnaire for on-site survey were distributed to 236 customers on their visit to the six national recreation forests. The main results of this study were as follows: the price sensitivity of big size was higher then small, also, the price sensitivity of log cabin was higher then forest-hotel. Present prices were within the range of acceptable prices except prices of the use of 6 and 7 person of log-cabin. From the result of this study, it was concluded that price adjustment or price promotion strategy would effective for increase in sales and marketing strategies to enhance consumers' perceptions of value should be conducted for two room types by situations.

A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry (약물검사 키트의 분석 민감도에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Lee, Hee Gyung;Kim, Hyun Jung;Lee, Yun Jung;Jin, Ok Bae;Kim, Mi Gyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

A Study on Receiver Sensitivity Measurement using Pilot $E_c/I_o$ Compensation Method at CDMA Communication Network (CDMA 기지국에서 Pilot $E_c/I_o$ 보상기법을 이용한 수신감도 측정에 관한 연구)

  • Jeong, Ki-Hyeok;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.8
    • /
    • pp.9-16
    • /
    • 2007
  • Currently, the measurement of RF parameters for a base station in operation is typically limited to easily measured forward path items. In this paper, the forward monitoring ports of base stations are used to measure the reverse RF performance. The system has been implemented and effectiveness has been proven on an operating base station. The receiver sensitivity is measured using an internal CDMA modem which is used to monitor the output power based on closed loop power control when the modem is connected to the base station via a voice call. In order to improve accuracy, in addition to the modem Tx adjust(TxAdj) parameter, the detector's actual measurement is used. For accurate receiver sensitivity, the measurement should be made when there is no traffic which is not possible on an operating base station. Therefore, pilot channel chip energy to received signal power spectral density ratio$(E_c/I_o)$ compensation method is used to offset the receiver sensitivity degradation with voice traffic increase.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

A Display-based Visual Stimulator for Psychophysical and Electrophysiological Color Sensitivity Measurements

  • Hwang, Jisoo;Park, Seung-Nam;Park, Cheol-Min;Lee, Geun Woo;Kim, Kiseong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.145-150
    • /
    • 2012
  • We present a display-based visual stimulator for psychophysical and electrophysiological visual sensitivity measurements. The stimulator offers various psychophysical visual stimuli and transfers the signals from external devices along with the stimulation signals to an electrophysiological recorder. As an experimental demonstration, we perform a visual sensitivity experiment in the mesopic vision range by using the display-based stimulator. The intensity of the steady-state visual evoked potential is observed to correlate with the luminance of the flickering visual stimulation. For the psychophysically determined detection thresholds, we determine the mesopic luminance, showing agreement with the perceived brightness within the uncertainty of the luminance measurement.