• Title/Summary/Keyword: Sensitivity Measurement

Search Result 1,318, Processing Time 0.024 seconds

Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method (초음파 센싱 방식의 spirometer에 대한 sensitivity 향상)

  • 한승헌;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.269-272
    • /
    • 2004
  • The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.

  • PDF

A Study on the Measurement Uncertainty of Pipe Prover (파이프 프루버의 측정불확도에 관한 연구)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

Ultrasensitive serum thyroglobulin the usefulness of evaluation (Ultrasensitive serum thyroglobulin의 유용성 평가)

  • Lee, Sun Ho;Cho, Eun Bit;Shin, Young Kyun;Lee, Young Ji;Yoo, Seun Hee;Kim, Nyun Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.102-107
    • /
    • 2015
  • Purpose Serum Thyroglobulin measurement is a major tool for the follow-up of differentiated thyroid cancer (DTC) patients. Thyroglobulin is Normal thyroid tissue, or thyroid cancer tissue produced only. Thyroid hormone to a halt without Tg differentiation of thyroid cancer recurrence just by measuring how to decide whether there was increasing expectations if I can do it instead. Therefore, in excellent sensitivity Tg new inspection of the functional sensitivity by measuring the looked to evaluate the usefulness of reagents. Thyroidectomy is measuring the numbers Tg (total thyroidectomy) remaining thyroid ablation and radioactive iodine (radioactive iodine remnant ablation, RRA) DTC in patients being diagnosed with or help predict the remaining early detection of thyroid cancer recurrence. Materials and Methods Agent that I'm currently using Tg of the measurements of low clinical specimen for a second drainage of the three (0.08 0.17, 0.98, ng/mL) within the scope of the dilute magnification (2, 4, 8, 16, 32 times) by dilute Intraassy (n=10) and Interassay (n=10) out in no time. Concentration value according to the coefficient of variation and the mean and standard deviation of each measurement (Coefficient of variation, CV) the absolute value of the measured values that corresponds to 20 percent target a coefficient of variation of CV Find the value of the concentration of the functional sensitivity measurement did. Also, analytical sensitivity with recovery rates, Dilution test inspections, and interrelationship, compared. Results Sensitivity is an excellent analytical sensitivity within the prosecutor kit Tg 0.006 ng/mL, and core analytical sensitivity, conducted by the 0.006 ng/mL to same conclusion. Be rather high to 142 percent recovery rate was 60 to measurement and functional sensitivity, 0.01766 ng/mL(Intraassay n=10) was measured at. CBC is relatively good correlation as ($R^2=0.949$) the correlation. Conclusion Recently ultrasensitive thyroglobulin this clinically important indicators of the previous kit and demands are lower than sensitivity to the measurement results. Therefore, ultrasensitive thyroglobulin test is correlated that there would be useful in value in nuclear medicine the thyroid gland.

  • PDF

Estimation of Sensitivity Axis Offset of an Accelerometer for Accurate Measurement of the 6 DOF Human Head Motion (인체 머리부 6 자유도 운동 측정의 신뢰성 향상을 위한 가속도계 감도축의 옵셋(offset) 추정)

  • Lee, Jeung-Hoon;Kim, Kwang-Joon;Jang, Han-Kee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.905-912
    • /
    • 2008
  • Notion sickness is well known to be caused by long time exposure to the very low frequency motion in the multiple axes of human body Since the vestibular system for the perception of low frequency motion is located in the head, accurate measurement of 6 degree of freedom head motion is of great importance. In this study, the measurement system consisting of a safety helmet and 9 translational accelerometers was constructed for the estimation of 3 translational and 3 rotational motions of human head. Since estimation errors of 3 rotational components can be significantly magnified even by small offset of the sensitivity axis from the geometric center of an accelerometer, accurate measurement of sensitivity axis must be preceded. The method for accurate estimation of the offset was proposed, and the effect of offset on the estimation of angular acceleration was investigated.

Measuring Expected Meal Duration for Restaurant Revenue Management (레스토랑 수익 관리를 위한 적정 식사 시간 측정에 관한 연구)

  • Cho, Mee-Hee;Lee, Kyung-Hee
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.2
    • /
    • pp.278-286
    • /
    • 2009
  • Restaurants have two strategic levers for revenue management: duration control and demand-based pricing. Reducing dining times, especially during peak periods, can add considerable revenue for restaurants. Managing meal duration, however, can be far more complex than manipulating the price. This paper examines dining duration expectations for restaurants types(Family, Korean, Quick service restaurant), customers characteristics(gender, age, occupation, meal period, visiting frequency, dining occasion, dining companions) using an a adaptation of a price sensitivity measurement tool, naming it 'Time Sensitivity measurement tool' or TSM. The TSM is then used to derive the optimal time points, and the range of acceptable times. The results demonstrate that there is a relatively wide spread of acceptable dining duration times in family restaurant. Furthermore, the optimal time points was shorter than the mean expected dining times, which suggests that many restaurants may be able to shorten dining duration without compromising customer satisfaction. The paper explores whether demographic and dining variables have an impact on time preferences, and finds whether gender, age, meal periods, visiting frequency, and dining companion effects are significant. Specifically, women in their thirties tended to prefer a significantly longer dining times for dinner.

  • PDF

The Comparison Between Blind and Normal Children in Standing Position (시각장애 아동과 정상 아동의 선자세 균형 비교)

  • Kim Chung-sun;Lee Jeong-soon
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.119-154
    • /
    • 2003
  • In this paper, the proprioceptive sensitivity was compared by Foot-Hand task method and the effect of the proprioceptive sensitivity and auditory to the standing position between blind and normal children was measured using BPM for 56 children in 7, 8, 9 and 10 years old. There are three measurement methods are used for BPM : Rest, Forward Looking, 'Sound' position. The following conclusions were obtained from the above measurements. 1. In comparison of proprioceptive sensitivity between blind and normal children, there is no significant difference(p > .05). There is no significant difference in comparison of each age group and also there is no difference in each gender group(p > .05). 2. In comparison of standing position measurement between blind and normal children, there is any difference (p > .05) in three measurement(Rest, Forward Looking, 'Sound' position) but there is no significant difference in each gender difference(p > .05). There is any difference between Rest and 'Sound' position of blind children, also there is any difference between Forward Looking and ' Sound ' position, rest and 'Sound' position of normal children(p > .05). 3. There is no significant difference of correlation between proprioceptive sensitivity test and standing position measurement in Pearson correlation coefficient(p > .05).

  • PDF

A Study on the Development and Measurement of Environmental Sensitivity among Middle School Environmental Class (환경감수성 측정을 위한 검사 도구 개발과 이를 이용한 환경감수성 측정 - 중등학교 환경반을 대상으로 -)

  • Lee, Jae-Boong;Lee, Du-Gon
    • Hwankyungkyoyuk
    • /
    • v.19 no.3
    • /
    • pp.138-149
    • /
    • 2006
  • The purpose of this study was to develop the environmental sensitivity(ES) measurement instrument and to apply for middle school students. The questionnaire was developed to evaluate ES. The developed questionnaire consists of 15 items in 5 categories. Each item of the instrument was developed through the conceptional analysis of the definition of ES. The 5 categories included natural environment, activity at natural environment, artificial environment, environmental pollution, environmental destruction. Data for this study were collected from 397 middle school students including 46 environmental class and 351 non-environmental class students. It was found that the developed instrument to measure ES was valid and reliable. Reliability coefficient, Cronbach $\alpha$ was 0.75. Using the developed instrument of ES, the ES was measured for the students of experimental group to which a inqury-based EE model was applied. The result was that the effect of ES of the students of the experimental group was not statistically significant. Futher research is needed related to the EE model based on the inquiry learning model and measurement of environmental sensitivity.

  • PDF

Deformation Measurement of Electronic Components in Mobile Device Using High Sensitivity Shadow Moiré Technique (고감도 그림자 무아레 기법을 이용한 모바일 전자부품의 변형 측정)

  • Yang, Hee-Gul;Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2017
  • The electronic components in mobile device are composed of electronic chips and various other materials. These components become extremely thin and the constituent materials have different coefficient of thermal expansion, so that considerable warpages occurs easily due to temperature change or external load. Shadow $moir{\acute{e}}$ is non-contact, whole field technique for measuring out-of-plane displacement, but the measurement sensitivity is not less than $50{\mu}m/fringe$, which is not suitable for measuring the warpage of the electronic components. In this paper, we implemented a measurement method with enhanced sensitivity of $25{\mu}m/fringe$ by investigating and optimizing various experimental conditions of the shadow $moir{\acute{e}}$. In addition, four $moir{\acute{e}}$ fringe patterns recorded by the phase shift are processes to obtain a $moir{\acute{e}}$ fringe patterns with a sensitivity four times higher. The measurement technique is applied to small electronic components of a smart phone for measuring warpage with a high sensitivity of $5{\mu}m/fringe$ at room temperature and at the temperature of $100^{\circ}C$.

Uncertainty Assessment Using Monte Carlo Simulation in Gas Flow Measurement (기체 유량 측정에서 몬테 카를로 모사를 이용한 측정불확도 평가)

  • Lee, Dae-Sung;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1758-1765
    • /
    • 2003
  • Monte Carlo simulation(MC) method was used as an uncertainty assessment tool for gas flow measurement in this paper. Uncertainty sources for gas flow measurement were analyzed, and probability distribution characteristics of each source were discussed. Detailed MC methodology was described including the effect of the number of simulation. The uncertainty result was compared with that of the conventional sensitivity coefficient method, and it was revealed that the results were different from each other for this particular gas flow measurement case of which the modelling equation was nonlinear. The MC was comparatively simple, convenient and accurate as an uncertainty assessment method, especially in cases of complex, nonlinear measurement modelling equations. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the measurement.