• Title/Summary/Keyword: Sensitivity Margin

Search Result 134, Processing Time 0.026 seconds

Sensitivity Analysis on the Seismic Responses of the Reactor Structures (원자로구조물의 지진응답 민감도해석)

  • Lee, J. H.;Kim, J. B.;Koo, G. H.;Kim, J. I.;Yoo, B.;Choi, S.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.183-190
    • /
    • 1993
  • The seismic response of the reactor structures depends on the dynamic charact-eristics of the structures and the input earthquake loadings. The stuctural integ-rity of the reactor internal components can be verified by the dynamic response analyses to implement the effects of the design loadings like earthquakes. The sensitivity analyses of the dynamic characteristics for the analytical model of reactor structures considering the possible variations of the stiffnesses of the CSB upper flange and the snubber were performed to improve the dynamic characteri-stics of the structures against seismic loading. And to enhance the structural design margin of the reactor internal components the nonlinear time history analyses were attempted for the modified analytical model, and the results were compared between the reference model and the modified ones.

  • PDF

Dynamic characteristics of optical pickup actuator with a newly designed electromagnetic circuit (신 자기회로가 적용된 광픽업 액추에이터의 동특성)

  • Park, Kwan-Woo;Kim, Jae-Eun;Jung, Jae-Hyun;Lee, Kyung-Taek;Ko, Eui-Seok;Hoon, Min-Byung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.512-514
    • /
    • 2008
  • In this paper, a new electromagnetic circuit is proposed for an optical pickup actuator with high sensitivity. Contrary to those of conventional actuators, the proposed circuit has two focusing coils which are diagonally placed at the front and rear of a moving part. The configuration which makes the effective length of the focusing coil longer and the moving part lighter, is helpful in increasing the sensitivity of the actuator. However, the asymmetry of the moving part by two focusing coils causes flexible node vibrations in quite low frequency range. This paper shows that the design modification of the moving part for the reconfiguration of mass moment of inertia can reduce the mode vibrations.

  • PDF

DDM Rotordynamic Design Sensitivity Analysis of an APU Turbogenerator Having a Spline Shaft Connection

  • Lee, An-Sung;Ha, Jin-Woong
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.57-63
    • /
    • 2003
  • An eigenvalue design sensitivity formulation of a general nonsymmetric-matrix rotor-bearing system is devised. using the DDM (direct differential method). Then, investigations on the design sensitivities of critical speeds are carried out for an APU turbogenerator with a spline shaft connection. Results show that the dependence of the rate of change of the critical speed on the stiffness changes of bearing models of spline shaft connection points is negligible, and thereby their modeling uncertainty does not present any problem. And the passing critical speeds up to the 4th critical speed are not sensitive to the design stiffness coefficients of four main bearings. Further, the dependence of the rate of change of the critical speed on the shaft-element length changes shows quantitatively that the spline shaft has some limited influence on the 4th critical speed but no influence on the 1st to 3rd critical speeds. With no adverse effect from the spline shaft, the APU system achieves a critical speed separation margin of more than 40% at a rated speed of 60,000 rpm.

Intra-Operative Frozen Sections: Experience at A Tertiary Care Centre

  • Preeti, Agarwal;Sameer, Gupta;Kulranjan, Singh;Abhinav, Sonkar Arun;Preeti, Rani;Sunita, Yadav;Mati, Goel Madhu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5057-5061
    • /
    • 2016
  • The present study was conducted to assess error rates with diagnosis using intra-operative frozen sections, and to indicate ways to increase overall performance. Over a period of two years, 227 cases were biopsied intra-operatively. Errors were observed in 14 cases. Four of these were sampling errors, one by a pathologist and three by surgeons. In seven cases incorrect interpretations were made. Epithelial dysplasia was observed on definitive histology in two cases which was not reported intra-operatively. One case was of ectopic thyroid. In cases of oral cancer where sentinel lymph nodes were sampled, immunohistochemistry for cytokeratin was performed to facilitate identification of micrometastasis. Only single case displayed tumor deposits which was not evident morphologically. Resection margins were reported in seventy eight cases. Some 18% (14/50) benefited from revision of margins; overall sensitivity of intra-operative frozen sections for marginal status was 71.4%, with a specificity of 90.3%. Overall sensitivity was 75% and specificity was 97.5%. Careful observation, pathologist experience and knowledge of limitations help in improving the overall diagnostic outcome.

A SENSITIVITY STUDY ON NEUTRONIC PROPERTIES OF DUPIC FUEL

  • Park, Hangbok;Roh, Gyu-Hog
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.124-129
    • /
    • 1998
  • A sensitivity study has been done to determine the composition of DUPIC fuel from the viewpoint of neutronics fuel design. The spent PWR fuel compositions were generated and fissile contents adjusted by blending fresh uranium after mixing two spent PWR fuel assemblies. The $^{239}$ Pu and $^{235}$ U enrichments of DUPIC fuel were adjusted by controlling the amount of fresh uranium feed and the ratio of slightly enriched and depleted uranium in the fled uranium. Based on the material balance calculation, it is recommended that DUPIC fuel composition be such that spent PWR fuel utilization is more than 90%.. A sensitivity study on the temperature reactivity coefficient of DUPIC fuel has shown that it is desirable to increase the $^{239}$ Pu and $^{235}$ U contents to reduce both the fuel and coolant temperature coefficients. On the other hand, refueling simulations of the DUPIC core have shown that the channel power peaking factor, which is a measure of the reactor trip margin, increases with the total fissile content. Considering these neutronic characteristics of the DUPIC fuel, il is recommended to have enrichments of 0.45 and 1.00 wt% for $^{239}$ Pu and $^{235}$ U, respectively.

  • PDF

Usefulness of Liver Fibrosis According to Classification of Image Score System In Abdominal Ultrasonography (복부 초음파검사에서 영상 점수 시스템 분류에 따른 간 섬유화 평가의 유용성)

  • An, Hyun;Ji, Tae-jeong;Lee, Hyo-young;Im, In-chul
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.187-194
    • /
    • 2019
  • The purpose of this study was to evaluate the pathologic results of hepatic parenchyma parameters such as liver parenchyma, liver surface, liver margin and liver, portal vein, spleen size, And to evaluate the usefulness of fibrosis progression and hepatic ultrasonography. The sensitivity, specificity, positive predictive value, and prognostic value according to the stage of fibrosis and grade of inflammation were divided into two groups according to the morphologic variable "A" through ultrasound and "B" We evaluated the predictive value and predicted the variables to evaluate fibrosis in clinical diagnosis and treatment of patients with chronic liver disease. The sensitivity and specificity of hepatic fibrosis in hepatic morphologic variables and other size variables were highest in liver surface and edge. The morphologic parameters used in the evaluation of fibrosis were clinically relevant in distinguishing the fibrosis stage from the results of liver biopsy.

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

Multipaction Sensitivity Analysis of X-band Output Filter for Geostationary Satellite (정지궤도위성 X-대역 출력필터 멀티팩션 민감도 해석)

  • Kim, Joong-Pyo;Lee, Sun-Ik;Lim, Won-Gyu;Kim, Sang-Goo;Lee, Sang-Kon
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.131-136
    • /
    • 2015
  • In this paper, prior to the flight model X-band dual-mode circular cavity filter required for the high power transmission of the observation payload in the geostationary satellite, the development model are designed and analyzed to show the analytical multipactor requirement margin. First of all, the multipaction breakdown power sensitivities were analyzed by changing the iris width and thickness within the filter, and through that the iris width and thickness was selected and then the multipaction threshold powers over the frequencies within the bandwidth were analyzed and the required margin of 8 dB was obtained. Also for the high power transmission filter, another important phenomena known as corona breakdown are analyzed for the iris width and thickness changes. Finally the development model manufactured was tested and the results met the key requirements.

Increasing Profitability of the Halal Cosmetics Industry using Configuration Modelling based on Indonesian and Malaysian Markets

  • Dalir, Sara;Olya, Hossein GT;Al-Ansi, Amr;Rahim, Alina Abdul;Lee, Hee-Yul
    • Journal of Korea Trade
    • /
    • v.24 no.8
    • /
    • pp.81-100
    • /
    • 2020
  • Purpose - Based on complexity theory, this study develops a configurational model to predict the profitability of Halal cosmetics firms in the Indonesian and Malaysian markets. The proposed research model involves two level configurations-industry context and selling strategies-to predict high and low scores of a firm's profitability. The industry context configuration model comprises industry stability, product homogeneity, price sensitivity, and switching cost. Selling strategies include customer-focused, competitor-focused, and margin-focused approaches. Design/methodology - This is the first empirical study that calculates causal models using a combination of industry context and selling strategy factors to predict profitability. Data obtained from the marketing managers of cosmetics firms are used to test the proposed configurational model using fuzzy-set qualitative comparative analysis (fsQCA). It contributes to the current knowledge of business marketing by identifying the factors necessary to achieve profitability using analysis of condition (ANC). Findings - The results revealed that unique and distinct models explain the conditions for high and low profitability in the Indonesian and Malaysian halal cosmetic markets. While customer-focused selling strategy is necessary to attain a higher profit in both the markets, margin-focused selling strategy appears to be an essential factor only in Malaysia. Complexity of the interactions of selling strategies with industry factors and differences between across two study markets confirmed that complexity theory can support the research configurational model. The theoretical and practical implications are also illustrated. Originality/value - Despite the rapid growth of the global halal industry, there is little knowledge about the halal cosmetic market. This study contributes to the current literature of the halal market by performing a set of asymmetric analytical approaches using a complex theoretical model. It also deepens our understating of how the Korean firms can approach the Muslim consumer's needs to generate more beneficial turnover/revenue.

New Optimal Tuning Method of IMC-PID for SI/SO Systems (단일 입출력 시스템에 대한 IMC-PID의 새로운 최적 동조법)

  • Kim, Chang-Hyun;Lim, Dong-Kyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.213-217
    • /
    • 2008
  • In this paper, a new design method for IMC-PID that adds a phase scaling factor of system identifications to the standard IMC-PID controller as a control parameter is proposed. Based on analytically derived frequency properties such as gain, phase margin and maximum magnitude of sensitivity function, this tuning rule is an optimal control method determining the optimum values of controlling factors to minimize the cost function, integral error criterion of the step response in time domain, in the constraints of design parameters to guarantee qualified frequency design specifications. The proposed controller improves existing single-parameter design methods of IMC-PID in the inflexibility problem to be able to consider various design specifications. Its effectiveness is examined by a simulation example, where a comparison of the performances obtained with the proposed tuning rule and with other common tuning rules is shown.

  • PDF